• Title/Summary/Keyword: Reuse Water

Search Result 494, Processing Time 0.028 seconds

Reuse of Weaving Wastewater with BAF Process (BAF 공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Kwon, Koo-Ho;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.664-669
    • /
    • 2004
  • An upflow BAF(Biological Aerated Filter) equipped with an expanded clay media was applied to reuse weaving wastewater of water jet loom. The performance of lab-scale biofilter was investigated by the adjustment of EBCTs(Empty Bed Contact Time) and the packing ratio of media, which were changed 1.1 to 3.7hr and 38 to 63%, respectively. In most conditions except 1.1hr of EBCT, BOD, CODcr, SS and Turbidity of the effluent were 1~4mg/L, 7~16mg/L, 1~5mg/L and 5~14NTU, where their removal efficiencies were 76~95%, 82~93%, 63~94% and 59~81%, respectively. From the observation of SEM(Scanning Electron Microscope) photographs of porous clay media, it was revealed that this media provided good performance of retaining microbes effectively. In addition, $0.44~0.49kgVSS/kgBOD_{rem}$. of low sludge reduction was expected. The most efficient back washing cycle and procedure were once per 4 to 9 days and air including collapse-pulsing method, respectively. Therefore, this system can be of use as an weaving wastewater treatment for reuse.

Reuse of Weaving Wastewater by Membrane Bioreactor Equipped with a Hollow-fiber MF Membrane (중공사 정밀여과 MBR공정을 이용한 제직폐수의 재이용)

  • Jung, Yong-Jun;Bae, Jong-Hong;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.4
    • /
    • pp.365-369
    • /
    • 2004
  • Submerged membrane bio-reactor equipped with a hollow fiber microfiltration was applied to reuse weaving wastewater of water jet loom, where two parameters such as the concentration of MLSS and the flux were controlled. While the flux at the concentration of MLSS around 900mg/L was constantly kept over 0.4m/d and 0.8m/d in a short time, the stable flux at around 300mg/L of MLSS was shown at the 8 days later. Regardless of MLSS and flux, BOD, CODcr and Turbidity of the permeate were 1~2mg/L, 7~10mg/L and below 1 NTU, which were 85~90%, 87~90% and 98% of removal efficiency, respectively. The stable operation without fouling was achieved because the contents of ECP were smaller than those of common MBR processes and the composition(saccharide/protein) was kept constantly. In this study, 0.5~1.0m/d of flux and 400~900mg/L of MLSS were considered as the most recommendable operating condition for the reuse of weaving wastewater.

Reuse Possibility of By-pass Flow and Secondary Effluent using BAF (BAF를 이용한 2차 처리수의 재이용 가능성 및 강우시 하수처리장 월류수의 처리)

  • An, J.H.;Park, J.B.;Kim, S.W.;Park, J.H.;Ha, J.S.;Choi, E.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.190-195
    • /
    • 2005
  • The laboratory and pilot scale BAFs (biological aerated filters) were operated with 0.3 hr to 1.1 hr EBCT(empty bed contact time) at a maximum filtration rate of $472m^3/m^2/day$ as a treatment method for reuse of secondary effluent and by-pass flow in this study. The effluent BOD and SS were generally 3.5 to 5 mg/L and 2 to 3 mg/L, respectively with 2ndary effluent, but the SS concentrations increased to 4 to 8 mg/L with the increased flow rates of by-pass flow. Potential nitrification rates were very high, but the nitrogen removal efficiencies were low due to the limited carbon sources. Bypass of a part of primary effluent seemed to be desirable to increase the nitrogen removal. Disinfection must be furnished for the reuse of BAF effluent.

Risk assessment of wastewater reuse for Irrigation water (하수처리수의 관개용수 재이용을 위한 위해성 평가)

  • Han, Jung-Yoon;Yoon, Chun-Gyeong;Jung, Kwang-Wook;Jang, Jae-Ho
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.661-666
    • /
    • 2005
  • Wastewater reuse are exposed public health risk by pathogens. Therefore, this study was examined for microbial risk assessment after irrigation as treated wastewater in paddy rice plots. Five treatments were used: biofilter effluent, UV disinfected water, pond treatment, wetland treatment and conventional irrigation water. Risk assessment was calculated based on the beta-Poisson model by concentration of E. coli from 2003 to 2005. Monte-Carlo simulation (n=10,000) was used to estimate the risk characterization of uncertainty. The risk range was from $10^{-5}$ to $10^{-8}$ except biofilter effluent was $10^{-4}$ in June. The USEPA(1992) has recommended that risk of < $10^{-4}$ is acceptable level of safety for potable waters. In 2005, risk value was lower than 2003, 2004 because of the first irrigation for plowing water is lower E. coli concentration used tap water. It is shown that the first irrigation water quality was important for wastewater irrigation in paddy. UV disinfection and natural treatment used pond and wetland were thought to be an effective for wastewater reuse.

  • PDF

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

A Feasibility Study on Sewage Discharge Water Treatment for Water Reuse by Direct Contact Membrane Distillation (하수처리수 재이용을 위한 직접접촉식 막증발법 적용 가능성 연구)

  • Choi, Yongjun;Choi, Jihyuck;Shin, Yonghyun;Cho, Hyeongrak;Sohn, Jinsik;Lee, Sangho
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2016
  • The reuse of wastewater is being diffused to manage and develop the water resources. Generally, the treated wastewater is discharged to the river after being treated to meet the effluent quality standard or reused for diverse uses through the reprocessing. And recently, as the reuse of the treated wastewater is activated, the technologies to utilize for the high quality water resources such as industrial water by reusing the wastewater with Membrane Distillation (MD) are under development. In this study, the direct contact membrane distillation (DCMD) process has been applied to treat sewage discharge water for water reuse. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$. The influence of operating parameters, such as feed temperature, feed flow rate, feed concentration, on the permeate flux and rejection has been investigated. All filtration tests were conducted till the feed volume reached a concentration factor of 3.0. Thus, the operating period ranged between 19 hr and 49 hr depending on filtration performance. The results showed that above 92% of TN, TP, COD and TOC in the feed could be rejected regardless of an operating condition. The water flux was ranged from 13.8 to 20.3 LMH. The lowest flux was obtained at the operating condition with the feed temperature of $50^{\circ}C$ and feed flow velocity of 500 mL/min while the highest one was measured with $60^{\circ}C$ and 900 mL/min. When the concentration factor reached 3.0, water flux declined by approximately ranged from 14.5% to 33.3%. But the fouling in MD is almost fully reversible, with more than 90% recovery of permeate water flux following a DI water rinse without the addition of chemical cleaning reagents.

Determinant Factor Analysis for the Spread of Water Reuse (물재이용 활성화를 위한 결정요인분석)

  • Park, Hyunju;Kim, Tschungil;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2014
  • The purpose of this study was to survey Suwon citizens over the age of 20 in order to provide basic data on the extent of coverage of the city's water reclamation system and to set guidelines for a policy on water reuse. The survey used a questionnaire with two fields, rainwater use and wastewater recycling, for analyzing factors that influenced water reuse. A factor analysis of 19 questionnaires gave a Cronbach's alpha coefficient greater than 0.4. Factors that influenced rainwater use were environmental protection, water charges, and the risk of climate change. Of the total explanatory power, the share of rainwater use and environmental protection was 39.7% and 28.1% respectively. Environmental protection (explanatory power 24.2%) had an effect on the explanatory power of wastewater reuse. When factors influencing wastewater recycling, like cost of recycling, water management policy, climate change, and suspension of tap water supply were included, the explanatory power of each of these factors went up by 4.3%, 2.8%, 3.3%, and 1.1%, respectively. For more effective wastewater recycling, a water management policy that factors in the above is required, along with a campaign to educate citizens on water management and environment conservation. Additionally, it may be necessary to improve the reliability and the quality of water supply.

TiO2 Reuse and Recovery from the Photocatalytic Oxidation of Cu(II)-EDTA using TiO2/UV-A System (TiO2/UV-A 시스템을 이용한 Cu(II)-EDTA의 광촉매 산화반응에서 TiO2 재사용 및 회수)

  • Lee, Seung-Mok
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.1
    • /
    • pp.84-91
    • /
    • 2005
  • $TiO_2-catalyst$ suspensions work efficiently in Photocatalytic oxidation (PCO) for wastewater treatment. Nevertheless, once photocatalysis is completed, separation of the catalyst from solution becomes the main problem. The PCO of Cu(II)-EDTA was studied to determine the reusability of the titanium dioxide catalyst. Aqueous solutions of $10^{-4}M$ Cu(II)-EDTA were treated using illuminated $TiO_2$ particles at pH 6 in a circulating reactor. $TiO_2$ was reused in PCO system for treatment of Cu(II)-EDTA comparing two procedures: reuse of water and $TiO_2$ and reuse of the entire suspension after PCO of Cu(II)-EDTA. The results are as follows; (i) Photocatalytic efficiency worsens with successive runs when catalyst and water are reused without separation and filtration, whereas, when $TiO_2$ is separated from water, the reused $TiO_2$ is not deactivated. (ii) The $TiO_2$ mean recovery (%) with reused $TiO_2$ was 86.4%(1.73g/L). Although the mean initial degradation rate of Cu(II)-EDTA and Cu(II) was lower than that using fresh $TiO_2$, there was no significant change in the rate during the course of the three-trial experiment. It is suggested that Cu(II)-EDTA could be effectively treated using an recycling procedure of PCO and catalyst recovery. (iii) However, without $TiO_2$ separation, the loss of efficiency of the PCO in the use of water and $TiO_2$ due to Cu(II), DOC remained from previous degradation and Cu(II)-EDTA added to the same suspension was observed after 2 trials, and resulted in the inhibition of the Cu(II)-EDTA, Cu(II) and DOC destruction.

A Treatment Efficiency of Wastewater by using Sym-Bio Process and Dissolved Ozone flotation Process for Water Reuse (하수처리수 재이용을 위하여 Sym-bio공정과 용존 오존 부상공정을 이용한 하수처리의 효율 분석)

  • Park, Changyu;Park, Jaehan;Lee, Kyunghee;Ahn, Yoonhee;Ko, Kwangbaik;Jung, Hyuncheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.86-90
    • /
    • 2008
  • Water reuse of effluent is limited, due to bacteria and chromaticity or turbidity which may result in low perception of water quality. Consequently, this study showed a method in the reuse of treated wastewater by a diversified treatment method, with separation of centralized reformation of aeration tank into pre-treatment with minimum installation of facilities, and post-treatment, applying advanced oxidation treatment. A pilot plant experiment was performed using Sym-Bio process adopting an NADH Sensor without modification of the exiting aeration tank. The Dissolved Ozone Flotation process, which is an advanced oxidation process, to treat the remaining organics, nutrients, chromaticity, turbidity and bacteria. As a result in the Sym-Bio process, the biological treatment, even on the condition of single stage reaction tank, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS and T-N were 96.6%, 84.6%, 88.25%, 95.1% and 71.0%, respectively, while that for T-P was 25.0%, which required further treatment. In the Dissolved Ozone Flotation process, the advanced oxidation treatment, the treatment efficiencies of BOD, $COD_{Mn}$, $COD_{Cr}$, SS, T-N, T-P, chromaticity, turbidity, bacteria, coliforms were 78.9%, 34.6%, 28.7%, 48.0%, 70.4%, 82.4%, 84.0%, 74.5%, 99.8% and 99.4%, respectively.

Quantitative and Qualitative Assessment of Blow Down Wastewater from Yeosu Industrial Complex (여수석유화학산단 산업폐수 재이용을 위한 블로우 다운 (Blow Down)수 발생현황 조사)

  • Kwon, Tae-Ouk;Moon, Il-Shik
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.3
    • /
    • pp.289-296
    • /
    • 2005
  • Purpose of this research is to quantitatively and qualitatively investigate the blow down wastewater produced from Yeosu Industrial Complex. Approximately, 38,325,000 tons/year of wastewater is produced, processed and finally discharged. Six representative companies, namely, A, B, C, D, E, F were chosen for this study. Each company produce over 5,000 tons/day of wastewater. In total, 6,844 tons/day of blow down water is produced from these six companies, put together. However, companies A and C produce about 24% and 37% of blow down water, respectively. It was found that the blow down water had favorable qualities, except for its high conductivity, ranging from 230 to $1,700{\mu}s/cm$. It was evident that, this water can be suitable for reuse, for industrial purposes, if a suitable treatment, for example, RO membrane process is adopted to remove high conductivity.