Browse > Article

Reuse Possibility of By-pass Flow and Secondary Effluent using BAF  

An, J.H. (Department of Civil & Environmental Engineering, Korea University)
Park, J.B. (The Korean Intellectual Property Office)
Kim, S.W. (Department of Civil & Environmental Engineering, Korea University)
Park, J.H. (Department of Civil & Environmental Engineering, Korea University)
Ha, J.S. (Department of Civil & Environmental Engineering, Korea University)
Choi, E. (Department of Civil & Environmental Engineering, Korea University)
Publication Information
Abstract
The laboratory and pilot scale BAFs (biological aerated filters) were operated with 0.3 hr to 1.1 hr EBCT(empty bed contact time) at a maximum filtration rate of $472m^3/m^2/day$ as a treatment method for reuse of secondary effluent and by-pass flow in this study. The effluent BOD and SS were generally 3.5 to 5 mg/L and 2 to 3 mg/L, respectively with 2ndary effluent, but the SS concentrations increased to 4 to 8 mg/L with the increased flow rates of by-pass flow. Potential nitrification rates were very high, but the nitrogen removal efficiencies were low due to the limited carbon sources. Bypass of a part of primary effluent seemed to be desirable to increase the nitrogen removal. Disinfection must be furnished for the reuse of BAF effluent.
Keywords
BAF; First flush; Nitrification; Reuse; Tertiary treatment; Reuse;
Citations & Related Records
연도 인용수 순위
  • Reference
1 환경부, 수질환경보전법 (2002)
2 Asano., Water from the Dependable Water Resource, Wat. Sci. Tech., 45(8), pp. 23-33 (2002)
3 Belgiorno, V., Feo, G. D., Napoli, R. M. A., Design Parameters of Biological Aerated Filters for Low Strength Domestic Wastewater, IWA Enviro 2002 proceeding, Melboum, Australia (2002)
4 Rother, E., Cornel, P., Ante, A., Kleiner, P. and Brambach, R., Comparison of Combined BAF Performance for Predenitrification Nitrification of Municipal Wastewater, Wat. Sci. Tech., 46(4-5), pp. 149-158 (2002)
5 강용태, 정동찬, BAF와 BAC에 의한 고도정수처리 시스템의 연구, 한국수처리기술연구회, 2(3), pp. 43-58 (1994)
6 Carucci, A., Farabelgoli, G., Gandolfo, G., Rolle, E. and Viotti, P., Experimental Study on Carbon Removal in Biological Aerated Filters, IWA 5th Specialised Conteference, Istanbul, Turkey (2002)
7 안지훈, BAF 공법을 이용한 CSO와 2차 처리수의 재이용화 가능성 연구, 고려대학교 석사학위 논문 (2004)
8 Payraudeau, M., Pearce, A. R., Goldsmith, R., Bigot, B., Wicquart, F., Experience with an Up-flow BAF for Tertiary Treatment: from Pilot Trials to Full Scale Implementation, Wat. Sci. Tech, 44(2-3), pp. 63-68 (2001).
9 Choi, E., Na, Y. H. and Lee, C. G., Low Temperature Nitrogen Removal by BAF from Weak Sewage, Proc of IWA conference on biofilm systems, session 5a, paper D24, New York (1999)
10 최의소 외., BAF 공법을 사용한 저온에서 하수에 대한 질소제거, 한국물환경학회 춘계학술대회 논문초록집, C-8, pp. 189-192 (1999)