• Title/Summary/Keyword: Return flow rate

Search Result 115, Processing Time 0.036 seconds

Energy Simulation for Conventional and Thermal-Load Controls in District Heating (지역난방의 일반제어 및 열량제어 에너지 시뮬레이션)

  • Lee, Sung-Wook;Hong, Hiki;Cho, Sung-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Korea district heating systems have mainly used setting temperature control and outdoor reset control. Different from such conventional normal methods, a thermal-load control proposed in Sweden can decrease the return temperature and reduce pump power consumptions because the control is able to provide the appropriate amount of required heat. In this study, further improved predictive optimal control in addition to the conventional controls were simulated in order to verify its effect in district heating system using TRNSYS 17. $200m^2$ apartment housing which accounts for 25% in Korea and is used as a calculation model;. the number of households in the simulation was 9. As a result, a higher temperature difference and decreasing flow rate at primary loop were shown when using thermal-load control.

A Clinical Study of Bidirectional Cavopulmonary Shunt (양방향성 상대정맥-폐동맥 단락술의 임상적 연구)

  • 지현근
    • Journal of Chest Surgery
    • /
    • v.28 no.8
    • /
    • pp.759-765
    • /
    • 1995
  • We reviewed our experiences on 33 patients who underwent a bidirectional cavopulmonary shunt[BCPS from February 1992 to July 1994. There were 19 male an 14 female patients, and their weight ranged from 4.4 to 13.3 Kg[mean weight 8.4 $\pm$2.9 Kg . The age ranged from 2 to 55 months [mean age 16.7 $\pm$15.5 months . Their diagnosis included single ventricle group in 16, unbalanced ventricles in 8 whose associated anomalies were double outlet right ventricle, transposition of great arteries and total anomalous pulmonary venous return, tricuspid atresia in 7, hypoplastic left heart syndrome in 1 who underwent a Norwood procedure and double outlet right ventricle with pulmonic stenosis and tricuspid stenosis in 1 who underwent biventricular repair. Among them 10 patients had received other palliative operation before [Norwood procedure 1, pulmonary artery banding 3, modified Blalock-Taussig shunt 6 . The BCPS operations were performed under the cardiopulmonary bypass. 16 patients underwent unilateral BCPS and 17 patients who had bilateral SVC underwent bilateral BCPS. Three patients whose associated anomalies were interruption of IVC underwent total cavopulmonary shunt. There were 5 operative deaths [mortality rate 15.1 % and 2 late deaths. The risk factor for the operation was high mean pulmonary artery pressure [p value<0.05 . The survivors showed good postoperative course and their postoperative oxygen saturation was increased significantly compared to that of preoperative status[p value<0.05 .Conclusively, BCPS operation is effective and safe palliative procedure for the many cyanotic complex congenital anomalies with decreased pulmonary blood flow especialy for the patients who have the high risk factors for Fontan operations.

  • PDF

Impact of Working Capital Management on Firm's Profitability: Empirical Evidence from Vietnam

  • NGUYEN, Anh Huu;PHAM, Huong Thanh;NGUYEN, Hang Thu
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.3
    • /
    • pp.115-125
    • /
    • 2020
  • This paper investigates the impact of working capital management on the firm's profitability. The research sample includes 119 non-financial listed companies on Vietnam stock market over a period of 9 years from 2010 to 2018. Two statistical approaches include Ordinary least squares (OLS) and fixed effects model (FEM) are employed to address econometric issues and to improve the accuracy of the regression coefficients. The empirical results show the negative and significant impacts of the working capital management, which measured by cash conversion cycle (CCC) and three components of the CCC including accounts receivable turnover in days (ARD), inventory turnover in days (INVD), and accounts payable turnover in days (APD) on the firm's profitability measured by return on assets (ROA) and Tobin's Q. It implies that firms can increase profitability by keeping the optimization of the working capital management measured by the CCC, which includes shortening the time to collect money from clients, accelerating inventory flow and hold the low payment time to creditors. Besides, the profitability of firms was impacted by the sale growth rate, firm size, leverage, and age. Therefore, this paper provides a new insight to managers on how to improve the firm's profitability with working capital management.

Development of piston contact mechanism for radial piston pump (레이디얼 피스톤 펌프의 피스톤 접촉 메커니즘 개발)

  • Ham, Y.B.;Cha, J.G.;Kim, D.M.;Kong, T.W.;Yun, S.N.;Ahn, K.Y.;Kweon, B.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.7 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • This paper presents the experimental results of the radial piston type oil pump with new mechanism for a metal diaphragm hydrogen compressor. Generally, metal diaphragm type hydrogen compressor systems are operated by oil hydraulic power. In this system an oil compensating pump has been demanded to compensate for a leakage oil head chamber. The metal diaphragm type hydrogen compressor consists of an oil compensating pump, commonly used hydraulic piston pump and driven by main crank shaft. The radial piston type oil compensating pump with new rolling contacted piston mechanism is developed and experimented. The developed piston element of the radial piston pump consists of piston, steel ball, return spring, two check valves, eccentric cam and ball racer. In this study, designed 4 type pistons as and orifice hole. Operating characteristics and pressure ripple characteristics are tested under no load to 60bar loaded with every 20bar increasing step and pressure ripple and flow rate are experimentally investigated.

  • PDF

A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating (난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발)

  • Kim, Yong-Ki;Woo, Nam-Sub;Lee, Tae-Won;Ahn, Byung-Cheon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF

The Meshfree Method Based on the Least-Squares Formulation for Elasto-Plasticity (탄소성 최소 제곱 수식화와 이를 이용한 무요소법)

  • Youn Sung-Kie;Kwon Kie-Chan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.6 s.237
    • /
    • pp.860-875
    • /
    • 2005
  • A new meshfree method for the analysis of elasto-plastic deformations is presented. The method is based on the proposed first-order least-squares formulation, to which the moving least-squares approximation is applied. The least-squares formulation for the classical elasto-plasticity and its extension to an incrementally objective formulation for finite deformations are proposed. In the formulation, the equilibrium equation and flow rule are enforced in least-squares sense, while the hardening law and loading/unloading condition are enforced exactly at each integration point. The closest point projection method for the integration of rate-form constitutive equation is inherently involved in the formulation, and thus the radial-return mapping algorithm is not performed explicitly. Also the penalty schemes for the enforcement of the boundary and frictional contact conditions are devised. The main benefit of the proposed method is that any structure of cells is not used during the whole process of analysis. Through some numerical examples of metal forming processes, the validity and effectiveness of the method are presented.

Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House (공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션)

  • Kim, J.Y.;Mim, M.K.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

Estimation of Return Flow Rate According to Demand Water Movement on Geum River (금강수계의 용수이동에 의한 회귀율 추정)

  • Maeng, Seung-Jin;Lee, Sang-Jin;Hwang, Man-Ha;Koh, Ick-Hwan;Kim, Man-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.11a
    • /
    • pp.367-370
    • /
    • 2007
  • 한국수자원공사에서 개발한 유출모의 모형인 RRFS의 입력자료로 사용되는 소유역별 각 용수에 대한 회귀율은 생공용수의 경우에는 65%, 농업용수의 경우에는 35%로 하여 일괄적으로 입력되어 있으나 이러한 값은 대략적으로 추정된 값이다. 따라서 본 연구에서는 금강수계내 전체에 대한 용수체계도를 대청댐 상류, 청주권, 대전권, 대청댐 하류 및 하구언권으로 구분하여 각 권역별로 작성하여 유출체계에 의한 메커니즘을 도시하였다. 본 연구에서는 체계적인 용수이용별 물이용수급현황 분석을 통해 물이용현황을 파악하는 것에 목적을 삼고 용수계통도 작성을 통한 권역별 용수체계를 분석하고자 하였다. 금강유역내 총 14개의 소유역에 대한 용수계통도 작성을 통해 용수수급현황을 분석하고, 궁극적으로 용수수급현황도를 작성하고자 각 권역별 하천 수계현황 조사, 용수사용현황 조사, 주요 용수시설물 현장조사 및 용수계통도를 작성하였다.

  • PDF

A Numerical Study on the Geometry Optimization of Internal Flow Passage in the Common-rail Diesel Injector for Improving Injection Performance (커먼레일 디젤인젝터의 분사성능 개선을 위한 내부유로형상 최적화에 관한 수치적 연구)

  • Moon, Seongjoon;Jeong, Soojin;Lee, Sangin;Kim, Taehun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.2
    • /
    • pp.91-99
    • /
    • 2014
  • The common-rail injectors are the most critical component of the CRDI diesel engines that dominantly affect engine performances through high pressure injection with exact control. Thus, from now on the advanced combustion technologies for common-rail diesel injection engine require high performance fuel injectors. Accordingly, the previous studies on the numerical and experimental analysis of the diesel injector have focused on a optimum geometry to induce proper injection rate. In this study, computational predictions of performance of the diesel injector have been performed to evaluate internal flow characteristics for various needle lift and the spray pattern at the nozzle exit. To our knowledge, three-dimensional computational fluid dynamics (CFD) model of the internal flow passage of an entire injector duct including injection and return routes has never been studied. In this study, major design parameters concerning internal routes in the injector are optimized by using a CFD analysis and Response Surface Method (RSM). The computational prediction of the internal flow characteristics of the common-rail diesel injector was carried out by using STAR-CCM+7.06 code. In this work, computations were carried out under the assumption that the internal flow passage is a steady-state condition at the maximum needle lift. The design parameters are optimized by using the L16 orthogonal array and polynomial regression, local-approximation characteristics of RSM. Meanwhile, the optimum values are confirmed to be valid in 95% confidence and 5% significance level through analysis of variance (ANOVA). In addition, optimal design and prototype design were confirmed by calculating the injection quantities, resulting in the improvement of the injection performance by more than 54%.