지중송전 편단접지개소에서의 병행지선 설치효과 검토 (Study on the Effect of Parallel Ground Conductor at the Single Point Bonding in Underground Transmission System)

  • 강지원;박흥석;윤형희;윤종건;배주호;석광현;오장만;김재승
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.736-737
    • /
    • 2007
  • The single point bonding in underground transmission system can induce high voltage on the sheath when ground fault, lightning serge and switching serge occurs, at that time underground cable systems cannot offer a return path of fault current. Accordingly if fault current, which cannot return to ground, flows at the single point bonding, high voltage can be induced in SVL and that voltage can cause aging and breakdown of SVL. Therefore this paper study on the effect of parallel ground conductor at the single point bonding when ground fault and lightning serge occurs by using ATPDraw.

  • PDF

지하매설 금속구조물의 전식방지 국내 현황 (Domestic Conditions on the Electrolytic Corrosion Protection of Buried Metallic Structures)

  • 이현구;하태현;최정희;정호성;배정효
    • 한국가스학회지
    • /
    • 제13권2호
    • /
    • pp.1-6
    • /
    • 2009
  • 누설전류는 의도된 회로 이외의 경로로 흐르는 전류를 말하며, 일반적으로 도시철도의 급전 시스템은 레일을 부극선으로 사용하기 때문에 레일이 대지와 완벽하게 절연되어 있지 않다면 레일을 통해 흐르는 전류의 일부는 누설전류로 땅속을 흐르게 된다. 이때 토양을 통해 누설 전류가 유출되는 레일과 지하매설 금속구조물에서 전식이 발생하게 된다. 본 논문에서는 국내 도시철도 운행지역 인근 지하매설 금속구조물의 전식방지 현황을 설문조사를 통하여 조사하였다.

  • PDF

Modulated Carrier Control for Interleaved Continuous Conduction Mode(CCM) Boost Power Factor Correction Converter

  • Kim, Hye-jin;Choi, Kyu-sik;Cho, B.H.;Choi, Hang-seok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.195-196
    • /
    • 2012
  • In recent years, in an effort to improve the efficiency and the power density of the front-end power factor correction(PFC), the interleaving of multiple converter is employed. The conventional interleaved continuous conduction mode(CCM) boost PFC converter requires input and output voltage sensing and three current sensing to obtain current balancing between modules. In this paper, the interleaved CCM PFC converter based on modulated carrier control is proposed. With the proposed method, two phase interleaved PFC can be realized simply without line voltage sensing resistor and can achieve current balancing without additional current sensing resistor on common return path. The simulation studies are carried out to verify the effectiveness of the proposed control scheme.

  • PDF

전기적 과도현상으로부터 통신망의 보호대책 (The Protection methods of Telecommunication Network from Electrical Transient Phenomena)

  • 최만호;김현덕;김병철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.693-696
    • /
    • 2005
  • 국내의 통신망은 효율적인 유지보수를 위하여 도로를 따라 기반시설이 구축되고 있기 때문에 전력망과 통신망의 교차와 병행이 가속화되고 있다. 전력망은 전력유도를 발생시킬 뿐만 아니라, 낙뢰와 같은 전기적 과도현상으로부터 그 자체가 전송매체로 되기 때문에 전력망 지중 접지체와 통신망 지중 접지체간을 통하여 낙뢰서지 및 지락선 과도 현상이 통신망에 유도되어 악영향을 초래한다. 본 연구에서는 통신망의 보호대책으로 지중접지체간의 이격거리를 통한 귀로전류의 차단과 양쪽 단자의 유휴심선을 접지하여 전력유도전압을 차폐하는 방법이 우수한 효과를 나타냄을 확인 할 수 있었다.

  • PDF

DC Motor Drive with Circuit Balancing Technique to Reduce Common Mode Conducted Noise

  • Jintanamaneerat, Jintanai;Srisawang, Arnon;Prempraneerach, Yothin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1881-1884
    • /
    • 2003
  • In some requirements of dc motor drive circuit applications are high quality output with generation of low internal conducted EMI. However the conventional dc motor drive circuits have been usually using unbalanced circuit which generates the high conducted EMI to the frame ground. This paper presents a balanced dc motor drive circuit which is effective way to reduce the common-mode noise. The circuit balancing is to make the noise pick up or occurring in both conductor lines, signal path and return path is equal in amplitude and opposite phase so that it will cancel out in the frame ground. The common-mode conducted noise reduction of this proposed dc motor drive is confirmed by experimental results.

  • PDF

Sheath Circulating Current Analysis of a Crossbonded Power Cable Systems

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.320-328
    • /
    • 2007
  • The sheath in underground power cables serves as a layer to prevent moisture ingress into the insulation layer and provide a path for earth return current. Nowadays, owing to the maturity of manufacturing technologies, there are normally no problems for the quality of the sheath itself. However, after the cable is laid in the cable tunnel and is operating as part of the transmission network, due to network construction and some unexpected factors, some problems may be caused to the sheath. One of them is the high sheath circulating current. In a power cable system, the uniform configuration of the cables between sections is sometimes difficult to achieve because of the geometrical limitation. This will cause the increase of sheath circulating current, which results in the increase of sheath loss and the decrease of permissible current. This paper will study the various characteristics and effects of sheath circulating current, and then will prove why the sheath current rises on the underground power cable system. A newly designed device known as the Power Cable Current Analyser, as well as ATP simulation and calculation equation are used for this analysis.

A Broadband Digital Step Attenuator with Low Phase Error and Low Insertion Loss in 0.18-${\mu}m$ SOI CMOS Technology

  • Cho, Moon-Kyu;Kim, Jeong-Geun;Baek, Donghyun
    • ETRI Journal
    • /
    • 제35권4호
    • /
    • pp.638-643
    • /
    • 2013
  • This paper presents a 5-bit digital step attenuator (DSA) using a commercial 0.18-${\mu}m$ silicon-on-insulator (SOI) process for the wideband phased array antenna. Both low insertion loss and low root mean square (RMS) phase error and amplitude error are achieved employing two attenuation topologies of the switched path attenuator and the switched T-type attenuator. The attenuation coverage of 31 dB with a least significant bit of 1 dB is achieved at DC to 20 GHz. The RMS phase error and amplitude error are less than $2.5^{\circ}$ and less than 0.5 dB, respectively. The measured insertion loss of the reference state is less than 5.5 dB at 10 GHz. The input return loss and output return loss are each less than 12 dB at DC to 20 GHz. The current consumption is nearly zero with a voltage supply of 1.8 V. The chip size is $0.93mm{\times}0.68mm$, including pads. To the best of the authors' knowledge, this is the first demonstration of a low phase error DC-to-20-GHz SOI DSA.

프레임을 연결하는 전도체의 구조가 EMI 감소에 미치는 영향 분석 (EMI Reduction Analysis by a Conductor between Frames)

  • 고은광;심민규;홍은주;이재열;박승훈;곽인구;나완수
    • 한국전자파학회논문지
    • /
    • 제19권2호
    • /
    • pp.263-270
    • /
    • 2008
  • 본 논문에서는 프레임들을 기계적으로 고정하고 전기적으로 접지시키기 위해 사용하는 전도체의 연결에 의한 전자파 장해의 감소에 대해서 연구하였다. 프레임과 프레임 사이의 전도체의 연결은 두 프레임 사이의 전류의 귀환 통로의 길이에 영향을 미친다. 전도체 연결의 효과를 입증하기 위해서 추가적인 전도체의 연결이 없는 경우와 케이블 하단에 세 가지의 크기가 다른 전도체를 연결해 주었을 때의 결과를 비교 분석하였다. 결과들로부터 전자파 장해가 측정 주파수 범위인 30 MHz$\sim$1 GHz에서 약 1$\sim$10 dB 감소함을 확인하였다. 네트워크 분석기를 이용하여 S 파라미터를, 또 3 m 무반향실에서의 복사성 방사를 측정하였으며, 두 파라미터 사이의 상관관계를 공진 주파수의 관점에서 확인하였다. 또한, 복사성 방사의 측정과 시뮬레이션 결과를 비교하였다.

Mobile 시스템을 위한 마이크로스트립 안테나 설계에 관한 연구 (A Study on the Desin of Microstrip Antenna for Mobile System)

  • 고영혁;이종악
    • 한국전자파학회지:전자파기술
    • /
    • 제4권2호
    • /
    • pp.34-40
    • /
    • 1993
  • Mobile 시스템을 위한 마이크로스트립 안테나는 공진 주파수가0.88GHz되게 섣계하였다. 마이크로스 트럽 어레이 안테나를 Tchebyscheff 다항식을 이용하여 구형 마이크보스트립 패치 크기에 의존하도록 상대적 전류 분포닫 1:4.69:1되게 설계하고 주 부엽 차를 20dB의 이펀치로 설계하였다. 설계된 마이크 로스트립 어레이 패치 안테나는 반사 손실, V.S.W.R, 방사 패턴, 벤드폭등 여라 특성을 측정하였고 이론치와 서로 일치함을 확인하였다 또한 빔 스케닝블 위해 상대적 전류 분포에 따른 패치 어레이 안테나의 위상 변환 과정을 제시했다.

  • PDF