• Title/Summary/Keyword: Retained rate

Search Result 256, Processing Time 0.029 seconds

Development and Control Technology of Austempered Ductile Irons with High Strength and High Toughness for Automotive Cam Shaft. (고강도 ADI의 자동차용 캠사프트 개발)

  • Kim, Jae-Yun;Kang, Dong-Myoung;Ahn, Sang-Uk;Kim, Kwang-Bae;Kang, In-Chan
    • Journal of Korea Foundry Society
    • /
    • v.11 no.3
    • /
    • pp.217-227
    • /
    • 1991
  • The present study was conducted to estimate the fatigue crack growth rate of the Mo-Ni alloyed ductile cast iron for the influence of austempering temperature and time. The fatigue crack growth rate was affected by retained austenite. Retained austenite volume were higher with the ductile cast irons which were austempered at $360^{\circ}C$ than austempered at $260^{\circ}C$, and the fatigue crack growth rate of the former was lower than that of the latter. Also, the fatigue growth rate of the former was the lowest at austempering for 1 hour and that of the latter was the lowest at austempering for 3 hours.

  • PDF

Clinical evaluation of implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles (Locator attachment를 이용한 하악 임플란트 유지형 피개의치의 임상적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.283-290
    • /
    • 2011
  • Purpose: This study compared the marginal bone loss around dental implant that were placed in the canine areas of the mandibles and finded the survival rate of implants, marginal bone loss around implants and prosthetic complications in 10 patients treated with overdentures retained with Locator attachments. Materials and methods: Ten patients who had received implant retained overdentures in the mandibules using two implants and Locator attachments at Daegu Catholic University Medical Center from 2004 to 2010 were included in this study. Evaluations of the survival rate of implants, marginal bone loss and prosthetic complications were performed. Results: Implants placed in this study showed a 100% survival rate and the average annual bone loss was 1.03 mm ${\pm}$ 0.20 mm in the first year. The patients have verbally indicated that they are comfortable and that their overdentures function well. But, implant retained overdentures had various prosthetic complications such as male change, relining, rebasing and denture fracture. Conclusion: Implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

Effect of Quenching Medium on the Mechanical Properties of ADI Treated GCD 50 (GCD 50의 ADI처리시 기계적 성질에 미치는 퀜칭 매질의 영향)

  • Kim, H.G.;Oh, I.S.;Kim, H.J.;Shin, K.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.3
    • /
    • pp.137-143
    • /
    • 2008
  • Effect of quenching medium on the mechanical properties of ductil iron GCD 50 has been investigated using ADI treated specimens. The specimens have been austenitized at $900^{\circ}C$ for 2 hours, followed by controlled cooling to $800^{\circ}C$ under the cooling rate of $0.05^{\circ}C/sec$, then austempered at $380^{\circ}C$, $330^{\circ}C$, $280^{\circ}C$ and $230^{\circ}C$ for 1 hour. The specimens treated in the salt of 5% water were found to have higher tensile strength than that of the normal salt bath. Elongation and impact energy increased in proportion to the increase of retained austenite volume fraction. The increase of cooling rate of the salt by the addition of 5% water to the salt resulted in the increase of retained austenite volume fraction and the formation of fine bainitic ferrite.

A Study on the Dry Wear Characteristics of Austempered Ductile Cast Iron (오스템퍼링 處理된 球狀黑鉛鑄鐵의 乾燥磨滅 特性에 관한 硏究)

  • 강명순;전태옥;김형자;박흥식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.489-496
    • /
    • 1988
  • This paper is studied to know wear mechanism in variation of austempering temperature and holding time of austempered ductile cast iron against mating material SM45C hardened by heat treatment. The wear tests were carried out by rubbing the annular surface of two test pieces in dry sliding friction. The wear mechanism was investigated by scanning electron microscopy and the retained austenite volume fraction was investigated by X-ray diffractometer. The experimental results show that the wear characteristics depend largely on the oxidation of the testing materials which is influenced by the sliding velocity and distance. The retained austenite has a negative effect during frictional contact because it has increased severe wear by softened surface layer. It is shown experimentally that hard metals have lower frictional resistance and hence the resistance to adhesion is increased due to stronger interatomic linking bonds and increase in the surface energy.

CAUSE OF TECHNICAL FAILURES OF CONICAL CROWN-RETAINED DENTURE (CCRD): A CLINICAL REPORT

  • Yi Yang-Jin;Cho Lee-Ra;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.714-719
    • /
    • 2003
  • Conical crown-retained denture (CCRD) has been used as a very effective treatment method in cases with few remaining teeth with heterogeneous prognosis. However, in spite of many advantages of CCRD, high technical failure rate was a problem to be considered. Incorrect path of insertion and excessive retention were thought to be the main cause of technical failure and to result from laboratory procedure with a coping misfit and/or a coping transfer error. In order to prevent this error, secure anchoring of inner coping and re-examination and milling of convergence angle were recommended on the master model from pick-up impression.

WEAR BEHAVIOR OF ATTACHMENTS FOR IMPLANT RETAINED OVERDENTURE ACCORDING TO MATERIAL IN VITRO

  • Lee Seok-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.747-761
    • /
    • 2003
  • Statement of problem. The proper materials of attachments for implant retained overdenture are unknown, such as the correlation between retention and abrasion, as well as the types of materials that are suitable for patrix and for matrix individually. Purpose of this study. The aim of this study was to select a proper clinical attachment system for a successful treatment as well as patient satisfaction. Methods. Retention and abrasion of 14 commercial attachments were measured during 15,000 removes. Results. A retentive part (matrix) which requires elasticity has to be made of gold while the patrix part which does not require elasticity has to be made of titanium. This gold matrix / titanium patrix combination showed the most retentive force and the least retention loss.

Influence of Freezing Rate on the Aroma Retention in a Freeze Drying System (동결건조 시스템에서 동결속도가 향미물질 보존에 미치는 영향)

  • Byun, Myung-Hee;Choi, Mi-Jung;Lee, Sung;Min, Sang-Gi
    • Food Science of Animal Resources
    • /
    • v.18 no.2
    • /
    • pp.176-184
    • /
    • 1998
  • The objective of this study was to investigate the effects of freezing rate on aroma retention and to examine the mechanism of aroma retention during freeze drying process. Our experiments were carried out with self-manufactured freeze-dryer. Gelatin gels (2% w / w, 80${\times}$20mm) containing diacetyl(2mg/ml) were frozen unidirectionally (Neumann's model) from the bottom at -45, -30, -20, and -15$^{\circ}C$ and followed with freeze-drying. Under the upper conditions we measured freezing rate and the change of temperature and pressure during freeze drying. Freeze-dried gelatins were cut horizontally into 5 mm thickness from the bottom measured and diacetly contents. Besides, we observed the effect of the relative humidity of the diacetyl contents freeze-dried gelatin during storage. The retained diacetyl content was increased at high freezing temperature and in order of 0∼5, 5∼10, 10∼15, 15∼20 mm section from the bottom of the sample. It was observed that the retained diacetyl content was high in 15∼20 mm section. The retained diacetyl content and freeze-dried gelatin stored in the condition of high relative humidity was decreased significantly but in the low relative humidity case, was it decreased in small amount. The results of our experiment resents that the low temperature freezing and low humidity storing condition is effective for preserving aroma compound in food.

  • PDF

An Analysis of the Frequencies of the Saury Heads(bait) Retained in the Tuna Stomachs (다랑어 위내에 들어있는 꽁치 머리의 빈도 해석)

  • PARK Sing Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.4
    • /
    • pp.312-316
    • /
    • 1982
  • With an object to obtain an indication on the efficiency of the saury baits for tuna longline, frequencies of the saury heads found in the tuna stomachs were analysed by the equations developed from tile binomial distribution. Four factors were introduced into the equations : The hooking rate, p; rate of not being hooked q; rate of the effective baits retained in the stomachs of the captured tuna r; and the rate of tile previously taken baits retained in the tuna stomachs, t. The best estimates of $\frac{p}{p+q^t}$ and r are empirically obtained as follows. Yellowfin tuna: $\frac{p}{p+q^t}$=0.789, r=0.598 Bigeye tuna: $\frac{p}{p+q^t}$=0.810 r=0.608, Albacore tun : $\frac{p}{p+q^t}$=0.838, r=0.621.

  • PDF

The Relationship between Retention of the Maternal Child Health Handbook, Awareness of DPT Additional Immunization and DPT Additional Immunization (모자보건수첩보유, 디피티 추가 예방접종에 대한 인지와 디피티 추가 예방접종 실천간의 관계연구)

  • Jeong, Ihn-Soak
    • Research in Community and Public Health Nursing
    • /
    • v.15 no.1
    • /
    • pp.76-83
    • /
    • 2004
  • Purpose: This study was aimed at investigating the relationship between retention of the maternal child health handbook, awareness of DPT additional immunization and DPT additional immunization, and to provide basic information to enhance the DPT additional immunization rate. Method: The study subjects were 312 women whose children were between four and six years old, and residing in six provinces of Gyungsangnam do. Data was collected with a 10 item questionnaire by interviews from July 1st to 30th, 2003, and analyzed with descriptive statistics and X2 test at a significance level of 0.05, by two tailed test. Results: The awareness of DPT additional immunization was significantly higher in the women who retained the maternal child health handbook, than their counterparts. The rate of DPT additional immunization was significantly higher in the women who were aware of the DPT additional immunization or who retained the maternal child health handbook, than their counterpart. Conclusion: The DPT additional immunization rate was related to retention of the maternal child health handbook and awareness of DPT additional immunization. Therefore it is recommended that measures be developed and taken to increase the retention rate of the maternal child health handbook and awareness of DPT additional immunization, to enhance the rate of DPT additional immunization.

  • PDF

A prospective multicenter clinical study on the efficiency of detachable ball- and spring-retained implant prosthesis

  • Min-Jung Kim;Won-Tak Cho;Su-Hyun Hwang;Ji-Hyeon Bae;Eun-Bin Bae;June-Sung Shim;Jong-Eun Kim;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.202-213
    • /
    • 2023
  • PURPOSE. This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP). MATERIALS AND METHODS. A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined. Periodic observational studies were conducted at 0, 3, 6, and 12 months after delivery of the implant prosthesis. Factors such as implant success rate, marginal bone resorption, periodontal pocket depth, plaque and bleeding index, and prosthetic complications were evaluated, respectively. RESULTS. During the 1-year observation period, all implants survived without functional problems and clinical mobility, showing a 100% implant success rate. Marginal bone resorption was significantly higher in the SCRP group than in the BSRP group only at the time of implant prosthesis delivery (P = .043). In all observation periods, periodontal pocket depth was slightly higher in the BSRP group than in the SCRP group, but there was no significant difference (P > .05). The modified plaque index (mPI) scores of both groups were moderate. Higher ratio of a score 2 in modified sulcus bleeding index (mBI) was observed in the BSRP group in the 6- and 12-months observation. CONCLUSION. Within the limitations of this study, the newly developed zirconia ball- and spring-retained implant prosthesis could be considered as an applicable and predictable treatment method along with the existing screw- and cement-retained prosthesis.