• 제목/요약/키워드: Response Threshold

검색결과 423건 처리시간 0.023초

토너입자형 디스플레이의 응답특성에 관한 연구 (A Study on Response Time Characteristics of Toner Particle Type Display)

  • 김인호;김영조
    • 한국전기전자재료학회논문지
    • /
    • 제22권1호
    • /
    • pp.93-97
    • /
    • 2009
  • We analyzed voltage characteristics of toner particle type display according to particle layers and cell gap between two electrodes and ascertained the aging effects by measuring the response time of particles with and without aging process. The threshold/driving/breakdown voltage is proportional to layers of toner particles and cell gap and the response time at driving voltage is faster than that of threshold and breakdown voltage because of different q/m of color and black particles. The analysis of response time is a method of estimation of optical characteristics, driving voltage and particle lumping and these results are promoted by aging process. We use the laser and photodiode to measure response time and optical properties. It has not been studied and reported to analyze the relationship of response time, threshold/driving/breakdown voltage, lumping phenomena, cell gap, and aging process for toner particle type display.

Percolation threshold and piezoresistive response of multi-wall carbon nanotube/cement composites

  • Nam, I.W.;Souri, H.;Lee, H.K.
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.217-231
    • /
    • 2016
  • The present work aims to develop piezoresistive sensors of excellent piezoresistive response attributable to change in nanoscale structures of multi-wall carbon nanotube (MWNT) embedded in cement. MWNT was distributed in a cement matrix by means of polymer wrapping method in tandem with the ultrasonication process. DC conductivity of the prepared samples exhibited the electrical percolation behavior and therefore the dispersion method adopted in this study was deemed effective. The integrity of piezoresistive response of the sensors was assessed in terms of stability, the maximum electrical resistance change rate, and sensitivity. A composite sensor with MWNT 0.2 wt.% showed the lowest stability and sensitivity, while the maximum electrical resistance change rate exhibited by this sample was the highest (96 %) among others and even higher than those found in the literature. This observation was presumably attributed by the percolation threshold and the tunneling effect. As a result of the MWNT content (0.2 wt.%) of the sensor being near the percolation threshold (0.25 wt.%), MWNTs were close to each other to trigger tunneling in response of external loading. The sensor with MWNT 0.2 wt.% was able to maintain the repeatable sensing capability while sustaining a vehicular loading on road, demonstrating the feasibility in traffic flow sensing application.

Development of the RE indirect-heating LPE furnace and the effect of impurity in YIG film on the MSSW properties

  • Fujino, M.;Fujii, T.;Sakabe, Y.
    • 한국결정성장학회지
    • /
    • 제12권6호
    • /
    • pp.288-291
    • /
    • 2002
  • We developed a new RF indirect-heating LPE furnace. The thermal gradient of our newly developed furnace is less than that of direct heating, and is as gentle as that of the resistance-heating LPE furnace. With this new furnace, the heating and/or cooling is faster than that of the resistance-heating furnace. Impurity-doped YIG film was grown from a $PbO-B_{2}O_{3}$, based flux on a (111) GGG substrate. To study the effect of the impurities on the MSSW threshold power and the saturation response time, we used two microstrip lines to excite and propagate the MSSW at 1.9 GHz. The MSSW threshold power and saturation response time was found to be related to the $\Delta$H.

고온에서 미세입자를 가진 석출경화형 Al-0.55 wt% Zr 합금의 Threshold 응력과 전위/입자의 상호 작용에 관한 연구 (Dislocation/Particles Interaction and Threshold Stress in Precipitation-Hardened Al-0.55 wt% Zr Alloy with Fine Particles at High-Temperature)

  • 김병일;나카지마 히데하루
    • 열처리공학회지
    • /
    • 제5권4호
    • /
    • pp.201-208
    • /
    • 1992
  • An experimental study of the constitutive response of precipitation-strengthened Al-0.55wt% Zr alloy, which consists of an Al matrix precipitation-strengthened by coherent particles, ${\beta}^{\prime}(Al_3Zr)$ with $L1_2$ structure has been performed. The deformation response of the materials has been examined by stress relaxation test at 573K, 623K and 673K. It was found that there exist the threshold stress during stress relaxation and threshold stress results from the presense of ${\beta}^{\prime}(Al_3Zr)$ particles. The ratio of threshold stress and Orowan stress decreased gradually with increasing temperature. The resistance to climb-pass of particles was independent of particles size for a fixed volume fraction although the threshold for bowing and particles cutting are sensitive to the particles dimensions. The smaller particles cutted by dislocations. This behavior of dislocations in this alloy was explained in terms of the small value antiphase boundary energy. The dislocation networks wrere more extensive in spesimens subjected to stress relaxation and there were numerous areas that have a high denstiy of jogged dislocation. This experiment results indicate that the rate controlling stress relaxation process is the climb of edge dislocation over particles.

  • PDF

마우스의 기도 내 점적을 통한 가습기살균제 CMIT/MIT와 사망 간의 원인적 연관성에 관한 연구 (Intra-tracheal Administration of the Disinfectant Chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) in a Mouse Model to Evaluate a Causal Association with Death)

  • 김하영;정용현;박영철
    • 한국환경보건학회지
    • /
    • 제43권4호
    • /
    • pp.247-256
    • /
    • 2017
  • Objectives: The deaths of Korean victims exposed to the disinfectant CMIT/MIT have remained unresolved. This is mainly due to a lack of concordance between the few available toxicity tests and the abundant epidemiological data, making it difficult to establish a cause-and-effect relationship. Therefore, this study was carried out to investigate any potential associations between CMIT/MIT exposure and death. Methods: Groups of experimental and control C57BL/6 mice were instilled (in the trachea) with chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) using a visual instillobot. CMIT/MIT was instilled over a period of three days and eight weeks, respectively, to achieve acute and chronic exposures. A threshold dose-response model was applied for estimating the threshold level as one line of evidence for a causal association between CMIT/MIT and death. Results: An acute exposure of 1.2 mg ai/kg/day of CMIT/MIT was estimated to reflect the threshold for death. The dose-response curve with this threshold showed a very steep slope and a narrow range of CMIT/MIT exposures. The narrow range of CMIT/MIT exposures, in particular, indicated an evident boundary between survival and death, thus implicating a strong causal association. A similar threshold dose-response relationship observed following acute exposure was also seen following chronic exposure to CMIT/MIT. Airborne disinfectant exposure was visible as minimal or mild lung damage with no fibrosis, as shown by histopathological tests. However, many observations are considered to be functional respiratory tract or lung failure due to death, as observed in necropsies of the mice that died due to CMIT/MIT exposures. Conclusions: There are two strong lines of evidence for a causal association between death and CMIT/MIT exposure: 1) The threshold dose-response curve, with a very steep slope and a narrow range of CMIT/MIT exposures showing a visible boundary between survival and death; and 2) many cases of functional respiratory or lung failure.

터보차져의 로터다이나믹 해석모델 개발 및 진동응답 해석 (Development of Rotordynamic Analytical Model and Analysis of Vibration Response of a Turbocharger)

  • 김병옥;이안성
    • 한국유체기계학회 논문집
    • /
    • 제13권5호
    • /
    • pp.35-42
    • /
    • 2010
  • This paper deals with the development of analytical model of a turbocharger and its detail rotordynamic analysis. Two analytical models, which are verified by experimental modal testing, are proposed and the analytical model including rotor shaft extended to compressor and turbine wheel end side is chosen. A rotordynamic analysis includes the critical map, Campbell diagram, stability, and unbalance response, especially nonlinear transient response considering nonlinear fluid film force at bearings. Although the linearized analysis accurately predicts the critical speeds, stability limit, and stability threshold speed, the predicted vibration results are not valid for speeds above the stability threshold speed since the rotor vibrates with a subsynchronous component much larger than the one synchronous with rotor speed. Hence, for operating speed above the stability threshold, a nonlinear transient analysis considering nonlinear fluid film force must be performed in order to accurately predict vibration responses of rotor and guarantee results of analysis.

Cumulative Impulse Response Functions for a Class of Threshold-Asymmetric GARCH Processes

  • Park, J.A.;Baek, J.S.;Hwang, S.Y.
    • Communications for Statistical Applications and Methods
    • /
    • 제17권2호
    • /
    • pp.255-261
    • /
    • 2010
  • A class of threshold-asymmetric GRACH(TGARCH, hereafter) models has been useful for explaining asymmetric volatilities in the field of financial time series. The cumulative impulse response function of a conditionally heteroscedastic time series often measures a degree of unstability in volatilities. In this article, a general form of the cumulative impulse response function of the TGARCH model is discussed. In particular, We present formula in their closed forms for the first two lower order models, viz., TGARCH(1, 1) and TGARCH(2, 2).

DEM으로부터 하천망 추출을 위한 흐름누적 임계값의 분석 (Analysis of Flowaccumulation Threshold Value to Extract Stream Network from DEM)

  • 김연준;양인태
    • 한국측량학회지
    • /
    • 제20권3호
    • /
    • pp.255-264
    • /
    • 2002
  • 지형은 강우시 유역의 유출반응을 결정하는 중요한 인자이다. 유역분석에서 하천망은 중요한 지형 매개변수이다. DEM격자 크기와 배수누적 행렬의 흐름누적 임계값은 격자 DEM를 이용하여 추출된 하천망에 영향을 미친다. 따라서 DEM에 의해서 추출된 하천망의 배수 밀도는 선택된 DEM 격자크기와 흐름누적 임계값에 따라 다양하다. 일반적으로 작은 흐름누적 임계값은 높은 배수밀도를 가지는 아주 세부적인 하천망을 만들어 내고, 큰 임계값은 조잡한 하천망을 만들어 낸다. 이 연구에서는 연구대상지역에서 총 하천길이가 각각의 DEM 격자크기에 대해 흐름누적 임계값을 계산하는데 이용되었다. 하천망은 흐름누적 임계값을 적용하여 각각의 DEM 격자크기에 대해 추출되었으며, 흐름누적 임계값과 각각의 DEM 격자크기에 연관성이 회귀방정식으로 도출되었다.

동적 여과 프로토콜 적용 센서 네트워크에서의 퍼지 기반 보안 경계 값 결정 기법 (A Threshold Determining Method for the Dynamic Filtering in Wireless Sensor Networks Using Fuzzy System)

  • 이상진;이해영;조대호
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2008년도 정보통신설비 학술대회
    • /
    • pp.197-200
    • /
    • 2008
  • In most sensor networks, nodes can be easily compromised by adversaries due to hostile environments. Adversaries may use compromised nodes to inject false reports into the sensor networks. Such false report attacks will cause false alarms that can waste real-world response effort, and draining the finite amount of energy resource in the battery-powered network. A dynamic enroute scheme proposed by Yu and Guan can detect and drop such false reports during the forwarding phase. In this scheme, choosing a threshold value is very important, as it trades off between security power and energy consumption. In this paper, we propose a threshold determining method which uses the fuzzy rule-based system. The base station periodically determines a threshold value though the fuzzy rule-based system. The number of cluster nodes, the value of the key dissemination limit, and the remaining energy of nodes are used to determine the threshold value.

  • PDF