• Title/Summary/Keyword: Response Rate

Search Result 5,493, Processing Time 0.032 seconds

Crack Detection in Eggshell by Acoustic Responses (음향반응에 의한 계란의 크랙검출에 관한 연구)

  • 조한근;최완규;백진하
    • Journal of Biosystems Engineering
    • /
    • v.23 no.1
    • /
    • pp.67-74
    • /
    • 1998
  • A nondestructive quality inspection technique using acoustic impulse response method was developed for eggshell inspection. An experimental system was built to generate the impact force, to measure the response signal and to analyze the frequency spectrum. This system includes an impulse generating unit, an egg holding seal a microphone with preamplifier, and a DSP board installed on Personal Computer. A simple algorithm .was developed for crack detection. Using the developed system with algorithm, crack detection ability was evaluated and the error rate to estimate the normal egg as cracked was found to be 4% and the error rate to estimate the cracked egg as normal was also found to be 4%. This system could be adopted in industry with some modification.

  • PDF

State Transition Model of Demand Response Considering Behavior Patterns of Customer (소비자의 행동 패턴을 고려한 수요반응의 상태 천이 모델)

  • Kwag, Hyung-Geun;Lee, Na-Eun;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.8
    • /
    • pp.1074-1079
    • /
    • 2013
  • Demand response(DR) is potential generation alternative to improve the reliability indices of system and load points. However, when demand resources scheduled in DR market fail to reduce demand, it can create new problems associated with maintaining a reliable supply. In this paper, a reliability model of demand resource is constructed considering customers' behaviors in the same form as conventional generation units, where availability and unavailability are associated with the simple two-state model. As a result, the generalized reliability model of demand resources is represented by multi-state model.

Electro-hydraulic Characteristic Analysis of Arm-type Implement for Three-point Hitch (3점 히치 장착형 암식 작업기의 전자유압특성 분석)

  • Lee, Sang-Sik;Park, Won-Yeop
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.314-318
    • /
    • 2011
  • Arm-type implements of tractor are mainly utilized for the slope land operation. The proposed hydraulic system was implemented to arm-type implements of tractor. An experiment was conducted to evaluate response characteristics of the designed arm-type implement control system attached by three-point hitch of tractor at various conditions, such as engine speed, pumping rate and cylinder input flow. Effects of the valve response time didn't affect engine speed. The flow rate of pump and cylinder changed to the pressure loss. Also, the pressure loss was within 2 MPa and the response characteristic was sufficient enough to use as the arm-type implement system.

Exergy analysis of heat pump in consideration of its dynamic response (동특성을 고려한 열펌프의 엑서지 해석)

  • 장기태;남관우;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.155-164
    • /
    • 1998
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the dynamic response of heat pump. First, a basic heat pump cycle is examined at steady state to show the general trends of exergy changes in each process of the cycle. Entropy generation issue in the exchangers is discussed to optimize the heat pump cycle. Second, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Third, the exergy destruction rate associated with the ON/OFF operations of the heat pump is calculated by simulating the thermodynamic states of the condenser and the evaporator. The inefficiency of the ON/OFF operation during the transient period is quantitatively revealed by the exergy analysis.

  • PDF

An Analysis on Treatment Schedule of Carbon Ion Therapy to Early Stage Lung Cancer

  • Sakata, Suoh;Miyamoto, Tadaaki;Tujii, Hirohiko
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.174-176
    • /
    • 2002
  • A total of 134 patients with stage 1 of non-small cell lung cancer treated by carbon ion beam of HIMAC NIRS were investigated for control rate and delivered dose. The delivered dose of every patient was converted to biological effective dose (BED) of LQ model using fraction number, dose per fraction and alpha beta ratio which shows the maximum correlation between BED and tumor control. The BED of every patient was classified to establish a BED response curve for control. Assuming fraction numbers, dose response curves were introduced from BED response curve. The total doses to realize several control rates were obtained for the treatment of small fraction number.

  • PDF

A Pooled Study on Combination of Gemcitabine and Nedaplatin for Treating Patients with Non-small Cell Lung Cancer

  • Yang, Song
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5963-5966
    • /
    • 2015
  • Background: This analysis was conducted to evaluate the efficacy and safety of a combination of gemcitabine and nedaplatin in treating patients with non-small cell lung cancer. Methods: Clinical studies evaluating the efficacy and safety of a combination of gemcitabine and nedaplatin with attention to response and safety for patients with non-small cell lung cancer were identified using a predefined search strategy. Pooled response rates for gemcitabine and nedaplatin were calculated. Results: In gemcitabine and nedaplatin based regimens, 4 clinical studies including 112 patients with non-small cell lung cancer were considered eligible for inclusion. The pooled analysis suggested that the pooled reponse rate was 40.2% (45/112). Main side effects included grade 3-4 neutropenia, thrombocytopenia, and anemia. Grade 3-4 nonhematological toxicity included nausea and vomiting, diarrhea, and hepatic dysfunction. There were no treatment-related deaths. Conclusion: This evidence based analysis suggests that the combination of gemcitabine and nedaplatin is associated with good response rate and accepted toxicity for treating patients with non-small cell lung cancer.

Unsteady Analysis of Acoustic-Pressure Responses of $N_{2}$ Diluted $H_{2}$ and Air Diffusion Flames (희석된 수소/공기 확산화염의 비정상 음향파 응답특성 해석)

  • Sohn, Chae-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.320-325
    • /
    • 2003
  • Acoustic-Pressure Response of diluted hydrogen-air diffusion flames is investigated numerically by adopting a fully unsteady analysis of flame structures. In the low-pressure regime, the amplification index remains low and constant at low frequencies. As acoustic frequency increases, finite-rate chemistry is enhanced through a nonlinear accumulation of heat release rate, leading to a high amplification index. Finally, the flame responses decrease at high frequency due to the response lag of the transport zone. For a medium-pressure operation and low-frequency excitation, the amplification index is low and constant. It then decreases at moderate frequencies. As frequency increases further, the amplification index increases appreciably due to an intense accumulation effect.

  • PDF

Analysis of Siloxane Adsorption Characteristics Using Response Surface Methodology

  • Park, Jin-Kyu;Lee, Gyeung-Mi;Lee, Chae-Young;Hur, Kwang-Beom;Lee, Nam-Hoon
    • Environmental Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.117-122
    • /
    • 2012
  • A central composite design and response surface methodology were applied to investigate the optimum conditions for maximum adsorption capacity in activated alumina as an adsorbent. The optimized conditions were determined for adsorption capacity using variables of flow rate and temperature. It was found that flow rate and temperature greatly influenced the adsorption capacity, as determined by analysis of variance analysis of these variables. Statistical checks indicated that second order polynomial equations were adequate for representing the experimental values. The optimum conditions for adsorption capacity were $0^{\circ}C$ and 2,718 mL/min, with the estimated maximum adsorption capacity of 17.82%. The experimental adsorption capacity was 17.75% under these optimum conditions, which was in agreement with the predicted value of 17.82%.

The Enhancement of the Defects Image in Solid by Increasing Vertical-Support Base for SFR(Spatial Frequency Response) (공간주파수응답의 수직기저대역 확장에 의한 고체 내부의 결함영상 개선)

  • Kim, Hyun
    • The Journal of Information Technology
    • /
    • v.5 no.2
    • /
    • pp.69-80
    • /
    • 2002
  • Conventionally, we have used an acoustic microscope at single operating frequency. The resolution and quality of the measured images are determined by transducer of the microscope. In this paper, we have studied Vertical Resolution Enhancement with Acoustic Reflection Microscope using combining bases of support for SFR(Spatial Frequency Response). Increased Vertical resolution can be obtained by taking three-dimensional images at more that one frequency and numerically combining the results. As results of the experiment, we could get enhanced images with the rate of contrast in proportion to the changing rate of depth.

  • PDF

Fast-Response Load Regulation of DC-DC Converter By High-Current Clamp

  • Senanayake, Thilak Ananda;Ninomiya, Tamotsu
    • Journal of Power Electronics
    • /
    • v.4 no.2
    • /
    • pp.87-95
    • /
    • 2004
  • A new fast-response high-current clamp DC-DC converter circuit design is presented that will meet the requirements and features of the new generation of microprocessors and digital systems. The clamp in the proposed converter amplifies the current in case of severe load changes and is able to produce high slew rate of output current and capability to keep constant the output voltage. This proposed high-current clamp technique is theoretically loss less, low cost and easy to implement with simple control scheme. This is modified from a basic buck topology by replacing the output inductor with two magnetically coupled inductors. Inductors are difference in inductance, one has large inductance and other has small inductance. The inductor with small inductance will take over the output inductor during fast load transient. It speedup the output current slew rate and reduce the output voltage drop in the case of heavy burden load changes.