• Title/Summary/Keyword: Respiratory cycle

Search Result 172, Processing Time 0.026 seconds

Various Factors Influencing Thoracic Duct Lymph Flow in the Dogs (임파유통에 영향을 주는 인자에 관한 실험적 연구)

  • Kim, Ki-Whan;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.45-56
    • /
    • 1975
  • Various factors influencing the lymph flow from thoracic duct were investigated in an attempt to evaluate their contributing degree and the mechanisms. Sixteen mongrel dogs weighing between 10 and 16 kg were anesthetized and polyethylene catheters were inserted into the thoracic duct and femoral veins. Arterial blood pressure, heart rate, central venous pressure, lymph pressure and lymph flow were measured under various conditions. Electrical stimulation of left sciatic nerve, stepwise increase of central venous pressure, manual application of rhythmical depressions onto abdomen, injection of hypertonic saline solution and histamine infusion were employed. Measurement of cental venous pressure was performed through the recording catheter inserted into abdominal inferior vena cava. Changes in central venous pressure were made by an air-ballooning catheter located higher than the tip of the recording catheter in the inferior vena cava. Lymph flow from thoracic duct was measured directly with a graduated centrifuge tube allowing the lymph to flow freely outward through the inserted cannula. The average side pressure of thoracic lymph was $1.1\;cmH_2O$ and lymph flow was 0.40 ml/min or 1.9 ml/kg-hr. Hemodynamic parameters including lymph flow were measure immediately before and after (or during) applying a condition. Stimulation of left sciatic nerve with a square wave (5/sec, 2 msec, 10V) caused the lymph flow to increase 1.4 times. The pattern of lymph flow from thoracic duct was not continuous throughout the respiratory cycle, but was continuous only during Inspiration. Slow and deep respiration appeared to increase the lymph flow than a rapid and shallow respiration. Relationship between central venous pressure and the lymph flow revealed a relatively direct proportionality; Regression equation was Lymph Flow (ml/kg-hr)=0.09 CVP$(cmH_2O)$+0.55, r=0.67. Manual depressions onto the abdomen in accordance with the respiratory cycle caused the lymph flow to increase most remarkably, e.g,. 5.5 times. The application of manual depressions showed a fluctuation of central venous pressure superimposed on the respiratory fluctuation. Hypertonic saline solution (2% NaCl) administered Intravenously by the amount of 10 m1/kg increased the lymph flow 4.6 times. The injection also increased arterial blood pressure, especially systolic Pressure, and the central venous pressure. Slow intravenous infusion of histamine with a rate of 14-32 ${\mu}g/min$ resulted in a remarkable increase in the lymph flow (4.7 times), in spite of much decrease in the blood pressure and a slight decrease in the central venous pressure.

  • PDF

A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing (명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구)

  • Hwang, Su Jung;Jung, Yoon Won;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2018
  • The purpose of this study is for fundamental research of meditation smart wear for physical and mental healing, and researching method for monitoring phase of meditation through textile by measuring the number of abdominal respiration when meditating. For this purpose, the research implemented Single Wall Carbon Nano-Tube (SWCNT) based strain gauges type textile sensor, considered reliability and validity of respiratory sensing, and analyzed efficiency of respiratory sensing based on body parts comparatively. The first preliminary experiment was to evaluate the performance of textile sensor through abdominal model dummy which open and shut of 5 cm repeatedly for 2 minutes at the rate of 0.1Hz in order to simulate abdominal respiration. It concluded signal efficiency between reference sensor(BIOPAC) and textile respiratory sensor appears statistically significant (p<0.001). The second experiment were conducted with 4 subjects doing abdominal respiration under same conditions, and after comparing the signal values between two sensors from 4 attached locations(around center and sides of omphali and phren), center of omphali and sides of phren were selected as suitable location for measuring meditational breathing as they showed large and stable signals. In result, this research aimed for implementing of the textile sensor for sensing meditational breathing of long respiration cycle, review of reliability and validity for sensing number of meditational respiration with the sensor and consideration of sensing efficiency by sensing location on body parts.

A Case Report of an Advanced Gastric Cancer Patient Who Was Able to Undergo Conversion Surgery Treated with Chemotherapy and Korean Medicine (항암화학요법과 한방치료를 병행하여 전환수술이 가능하게 호전된 진행성 위암 환자 1례)

  • Jang, Kwon-jun;Ko, Eun-bi;Hwang, Woo-seok;Kim, Kwan-il;Lee, Beom-joon;Jung, Hee-jae;Shin, Kwang-soon
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.5
    • /
    • pp.911-925
    • /
    • 2020
  • Objectives: The purpose of this study was to report a case of a patient with advanced gastric cancer with peritoneal metastasis treated with chemotherapy and Korean medicine Methods: A patient with advanced gastric cancer with peritoneal metastasis was treated with Xeloda/cisplatin since April 2019. The cycle was repeated every three weeks for a total of 11 times. At the same time, the patient was treated with Korean medicine. The tumor size was measured by computed tomography (CT) and esophagogastroduodenoscopy (EGD). Adverse events were evaluated by the National Cancer Institute Common Terminology Criteria for Adverse Events (NCI-CTCAE), version 5.0. Results: After treatment with Xeloda/cisplatin and Korean medicine for nine months, the extent of the proximal portion of the primary tumor and the size and number of multiple nodules around the stomach decreased and the cancer cells with peritoneal metastasis disappeared. The symptoms of discomfort and physical activity were gradually improved. As a result, the patient underwent conversion surgery. Conclusions: This case study suggests that the combination of chemotherapy and Korean medicine may contribute to the reduction in tumor size as well as the improvement in the quality of life.

A Case of Functional Upper Airway Obstruction Due to Vocal Cord Dysfunction in Obstructive Pulmonary Disease (폐쇄성 폐질환에 동반된 성대 운동이상에 의한 기능성 상기도폐색 1예)

  • Oh, Myoung;Kim, Sang-Cheol;Baik, Jae-Joong;Chung, Yeon-Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.3
    • /
    • pp.270-274
    • /
    • 2001
  • A functional upper airway obstruction due to a vocal cord dysfunction(VCD) is characterized by a paradoxical adduction of the vocal cords throughout the respiratory cycle with no obvious organic cause for the obstruction. It commonly occurs paroxysmally and imitates acute asthmatic attacks, often in patients with coexisting asthma. They present with episodes of dyspnea associated with inspiratory wheezing that persists despite conventional asthma treatment and a flattening of the inspiratory limb of the flow-volume curve ; an adduction of the vocal cord during inspiration. Failure to recognize concurrent vocal cord dysfunction and asthma has led not only to the excessive use of bronchodilators and corticosteroids, but also to intubation and tracheostomy. Here, we report a case of coexistent obstructive pulmonary disease and functional upper airway obstruction due to a vocal cord dysfunction where a bronchoscopy showed a paradoxical vocal cord motion and typical features of a variable extrathoracic obstruction and a lower airway obstruction on the Flow-volume loop during a symptomatic period.

  • PDF

Study on the Validation of the Gated Cone-Beam Computed Tomography on Radiation Therapeutic Linear Accelerator (방사선치료용 선형가속기를 이용한 Gated Cone-Beam CT의 유용성 연구)

  • Seo, Jeong-Min;Kim, Chan-Hyeong;Park, Byoung-Suk;Park, Cheol-Soo;Jang, Hyon-Chol;Kim, Joung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6932-6939
    • /
    • 2015
  • The respiration is one of important factor in the radiation therapy. The existing commercial method of cone-beam computed tomography on LINAC does not consider respiratory motion of patient hence the images are both distorted and inaccurate. In this study, the cone-beam computed tomography images have been reconstructed from back projection radiography of specific phase on breathing cycle which concerned about respiratory movement in radiation therapy. This study investigated how different between cone-beam CT images with and without gating respiratory movement, and this paper provides that guide and implementation of gated cone-beam CT on radiation therapeutic equipment.

Bufalin, a Traditional Oriental Medicine, Induces Apoptosis in Human Cancer Cells

  • Takai, Noriyuki;Kira, Naoko;Ishii, Terukazu;Yoshida, Toshie;Nishida, Masakazu;Nishida, Yoshihiro;Nasu, Kaei;Narahara, Hisashi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.399-402
    • /
    • 2012
  • Bufalin is a traditional oriental medicines which induces apoptosis in some lines of human tumor cells. It constitutes the major digoxin-like immunoreactive component of Chan Su, obtained from the skin and parotid venom glands of toads. Bufalin is cardioactive C-24 steroids that exhibits a variety of biological activities, such as cardiotonic, anaesthetic, blood pressure stimulatory, respiratory and antineoplastic effects. In terms of its anti-tumor activity, bufalin has been demonstrated to inhibit the growth of tumors, such as endometrial and ovarian cancers. This commentary introduces biologic and therapeutic effects of bufalin in treating some cancers. The compound is able to mediate inhibition of cell growth, cell cycle arrest, apoptosis, and expression of genes related to the malignant phenotype in human cancer cells.

Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

  • Lee, Soo Yong;Lim, Sangwook;Ma, Sun Young;Yu, Jesang
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.274-280
    • /
    • 2017
  • Purpose: To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods: We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%-60%, 30%-70%, and 0%-90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results: The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion: As narrow as possible duty cycle such as 40%-60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

Development of Artificial Pulmonary Nodule for Evaluation of Motion on Diagnostic Imaging and Radiotherapy (움직임 기반 진단 및 치료 평가를 위한 인공폐결절 개발)

  • Woo, Sang-Keun;Park, Nohwon;Park, Seungwoo;Yu, Jung Woo;Han, Suchul;Lee, Seungjun;Kim, Kyeong Min;Kang, Joo Hyun;Ji, Young Hoon;Eom, Kidong
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.76-83
    • /
    • 2013
  • Previous studies about effect of respiratory motion on diagnostic imaging and radiation therapy have been performed by monitoring external motions but these can not reflect internal organ motion well. The aim of this study was to develope the artificial pulmonary nodule able to perform non-invasive implantation to dogs in the thorax and to evaluate applicability of the model to respiratory motion studies on PET image acquisition and radiation delivery by phantom studies. Artificial pulmonary nodule was developed on the basis of 8 Fr disposable gastric feeding tube. Four anesthetized dogs underwent implantation of the models via trachea and implanted locations of the models were confirmed by fluoroscopic images. Artificial pulmonary nodule models for PET injected $^{18}F$-FDG and mounted on the respiratory motion phantom. PET images of those acquired under static, 10-rpm- and 15-rpm-longitudinal round motion status. Artificial pulmonary nodule models for radiation delivery inserted glass dosemeter and mounted on the respiratory motion phantom. Radiation delivery was performed at 1 Gy under static, 10-rpm- and 15-rpm-longitudinal round motion status. Fluoroscpic images showed that all models implanted in the proximal caudal bronchiole and location of models changed as respiratory cycle. Artificial pulmonary nodule model showed motion artifact as respiratory motion on PET images. SNR of respiratory gated images was 7.21. which was decreased when compared with that of reference images 10.15. However, counts of respiratory images on profiles showed similar pattern with those of reference images when compared with those of static images, and it is assured that reconstruction of images using by respiratory gating improved image quality. Delivery dose to glass dosemeter inserted in the models were same under static and 10-rpm-longitudinal motion status with 0.91 Gy, but dose delivered under 15-rpm-longitudinal motion status was decreased with 0.90 Gy. Mild decrease of delivered radiation dose confirmed by electrometer. The model implanted in the proximal caudal bronchiole with high feasibility and reflected pulmonary internal motion on fluoroscopic images. Motion artifact could show on PET images and respiratory motion resulted in mild blurring during radiation delivery. So, the artificial pulmonary nodule model will be useful tools for study about evaluation of motion on diagnostic imaging and radiation therapy using laboratory animals.

The Change of Cell-cycle Related Proteins and Tumor Suppressive Effect in Non-small Cell Lung Cancer Cell Line after Transfection of p16(MTS1) Gene (폐암세포에 p16 (MTS1) 유전자 주입후 암생성능의 변화 및 세포주기관련 단백질의 변동에 관한 연구)

  • Kim, Young-Whan;Kim, Jae-Yeol;Yoo, Chul-Gyu;Han, Sung-Koo;Shim, Young-Soo;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.796-805
    • /
    • 1997
  • Background : It is clear that deregulation of cell cycle progression is a hallmark of neoplastic transformation and genes involved in the $G_1$/S transition of the cell cycle are especially frequent targets for mutations in human cancers, including lung cancer. p16 gene product, one of the G1 cell-cycle related proteins, that is recently identified plays an important role in the negative regulation of the the kinase activity of the cyclin dependent kinase (cdk) enzymes. Therefore p16 gene is known to be an important tumor suppressor gene and is also called MTS1 (multiple tumor suppressor 1). No more oncogenes have been reported to be frequently related to multiple different malignancies than the alterations of p16 gene. Especially when it comes to non-small cell lung cancer, there was no expression of p16 in more than 70% of cell lines examined. And also it is speculated that p16 gene could exert a key role in the development of non-small cell lung cancer. This study was designed to evaluate whether p16 gene could be used as a candidate for gene therapy of non-small cell lung cancer. Methods : After the extraction of total RNA from normal fibroblast cell line and subsequent reverse transcriptase reaction and polymerase chain reaction, the amplified p16 cDNA was subcloned into eukaryotic expression plasmid vector, pRC-CMV. The constructed pRC-CMV-p16 was transfected into the NCI-H441 NSCLC cell line using lipofectin. The changes of G1 cell-cycle related proteins were investigated with Western blot analysis and immunoprecipitation after extraction of proteins from cell lysates and tumor suppressive effect was observed by clonogenic assay. Results : (1) p16(-) NCI-H441 cell line transfected with pRC-CMV-p16 showed the formation of p16 : cdk 4 complex and decreased phosphorylated Rb protein, while control cell line did not. (2) Clonogenic assay demonstrated that the number of colony formation was markedly decreased in p16(-) NCI-H441 cell line transfected with pRC-CMV-p16 than the control cell line. Conclusion : It is confirmed that the expression of p16 protein in p16 absent NSCLC cell line with the gene transfection leads to p16 : cdk4 complex formation, subsequent decrease of phosphorylated pRb protein and ultimately tumor suppressive effects. And also it provides the foundation for the application of p16 gene as a important candidate for the gene therapy of NSCLC.

  • PDF

Efficacy of a Respiratory Training System on the Regularity of Breathing (호흡연습장치를 적용한 호흡교정법의 영향 평가)

  • Shin, Eun-Hyuk;Park, Hee-Chul;Han, Young-YIh;Ju, Sang-Gyu;Shin, Jung-Suk;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.181-188
    • /
    • 2008
  • Purpose: In order to enhance the efficiency of respiratory gated 4-dimensional radiation therapy for more regular and stable respiratory period and amplitude, a respiration training system was designed, and its efficacy was evaluated. Materials and Methods: The experiment was designed to measure the difference in respiration regularity following the use of a training system. A total of 11 subjects (9 volunteers and 2 patients) were included in the experiments. Three different breathing signals, including free breathing (free-breathing), guided breathing that followed training software (guided-breathing), and free breathing after the guided-breathing (post guided-breathing), were consecutively recorded in each subject. The peak-to-peak (PTP) period of the breathing signal, standard deviation (SD), peak-amplitude and its SD, area of the one cycle of the breathing wave form, and its root mean square (RMS) were measured and computed. Results: The temporal regularity was significantly improved in guided-breathing since the SD of breathing period reduced (free-breathing 0.568 vs guided-breathing 0.344, p=0.0013). The SD of the breathing period representing the post guided-breathing was also reduced, but the difference was not statistically significant (free-breathing 0.568 vs. guided-breathing 0.512, p=ns). Also the SD of measured amplitude was reduced in guided-breathing (free-breathing 1.317 vs. guided-breathing 1.068, p=0.187), although not significant. This indicated that the tidal volume for each breath was kept more even in guided-breathing compared to free-breathing. There was no change in breathing pattern between free-breathing and guided-breathing. The average area of breathing wave form and its RMS in postguided-breathing, however, was reduced by 7% and 5.9%, respectively. Conclusion: The guided-breathing was more stable and regular than the other forms of breathing data. Therefore, the developed respiratory training system was effective in improving the temporal regularity and maintaining a more even tidal volume.