• Title/Summary/Keyword: Respiration sensor

Search Result 101, Processing Time 0.019 seconds

Development of a Respiration Sensor Using Plastic Optical Fiber (플라스틱 광섬유를 이용한 호흡센서의 개발)

  • Yoo, Wook-Jae;Baek, Ji-Yun;Cho, Dong-Hyun;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Cho, Young-Ho;Park, Byung-Gi;Moon, Joo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.489-494
    • /
    • 2009
  • In this study, we fabricated a plastic optical fiber based sensor which can monitor the respiration of a patient. The circumference changes of the abdomen were measured using a mirror, a light source and optical detectors because the circumferences of the abdomen could be varied with respiration. The intensity of the reflected lights were measured according to the changes of distance between mirror and plastic optical fiber connected to a light source and a photodiode-amplifier system using a Y-coupler. The respiration signals of fiber-optic sensor system were compared with those of the respiratory and temperature transducers of the $BIOPAC^{(R)}$ system. It is expected that a fiber-optic respiration sensor could be developed for real time respiration monitoring during MRI procedure based on this study.

A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing (명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구)

  • Hwang, Su Jung;Jung, Yoon Won;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2018
  • The purpose of this study is for fundamental research of meditation smart wear for physical and mental healing, and researching method for monitoring phase of meditation through textile by measuring the number of abdominal respiration when meditating. For this purpose, the research implemented Single Wall Carbon Nano-Tube (SWCNT) based strain gauges type textile sensor, considered reliability and validity of respiratory sensing, and analyzed efficiency of respiratory sensing based on body parts comparatively. The first preliminary experiment was to evaluate the performance of textile sensor through abdominal model dummy which open and shut of 5 cm repeatedly for 2 minutes at the rate of 0.1Hz in order to simulate abdominal respiration. It concluded signal efficiency between reference sensor(BIOPAC) and textile respiratory sensor appears statistically significant (p<0.001). The second experiment were conducted with 4 subjects doing abdominal respiration under same conditions, and after comparing the signal values between two sensors from 4 attached locations(around center and sides of omphali and phren), center of omphali and sides of phren were selected as suitable location for measuring meditational breathing as they showed large and stable signals. In result, this research aimed for implementing of the textile sensor for sensing meditational breathing of long respiration cycle, review of reliability and validity for sensing number of meditational respiration with the sensor and consideration of sensing efficiency by sensing location on body parts.

A pressure sensor system for detecting driver's drowsiness based on the respiration Paper Template for the KITS Review (호흡기반 운전자 졸음 감지를 위한 압력센서 시스템)

  • Kim, Jaewoo;Park, Jaehee;Lee, Jaecheon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.45-51
    • /
    • 2013
  • In this paper, a driver's drowsy detection sensor system based on the respiration is investigated. The sensor system consists of a piezoelectric pressure sensor attached at the abdominal region of the seat belt and a personal computer. The piezoelectric pressure sensor was utilized for the measurement of pressure variations induced by the movement of the driver abdomen during breathing. The signal processing software for detecting driver's drowsiness was produced using the Labview. The experiments were performed with 30 years male driver. The amplitude of the respiration at awake state was larger than one at the drowsy state. On the contrary, the respiration rate at awake state was lower than one at the drowsy state. The drowsy detection sensor system developed based on the experimental could successfully detect the driver's drowsy on real-time.

The Modeling of the Differential Measurement of Air Pressure for Non-intrusive Sleep Monitoring Sensor System

  • Chee, Young-Joon;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.373-381
    • /
    • 2005
  • The respiratory and heart beat signals are the fundamental physiological signals for sleep monitoring in the home. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body which makes long term measurement difficult and troublesome. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The concept of the balancing tube between two air cells is suggested to increase the robustness against postural changes during the measurement period. With this balancing tube, the meaningful frequency range could be selected by the pneumatic filter method. The mathematical model for the air mattress and balancing tube was suggested and the validation experiments were performed for step and sinusoidal input. The results show that the balancing tube can eliminate the low frequency component between two cells effectively. This technique was applied to measure the respiration and heart beat on the bed, which shows the potential applications for sleep monitoring device in home. With the analysis of the waveform, respiration intervals and heart beat intervals were calculated and compared with the signal from conventional methods. The results show that the measurement from air mattress with balancing tube can be used for monitoring respiration and heart beat in various situations.

Implementation of a Respiration Measurement System Based on a Nonrestraint Approach (무구속 방식의 호흡 측정 시스템 구현)

  • Cho, Seok-Hyang;Cho, Seung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.11
    • /
    • pp.33-41
    • /
    • 2014
  • In this paper, we implemented a system to measure respiration rate with nonrestraint sensors comfortable for people to do their everyday life. The proposed system consists of a pad covered with a Piezoelectric sensor, a respiration measuring device able to send the signal data after amplifying and filtering the source signals to the viewer, a viewer providing sensor data visualization and implementing the respiration measuring algorithm. The algorithm is based on a breathing cycle with the local peak points extracted from threshold on sensor data. Respiration measurements on 3 subjects were performed by changing moving averages and thresholds. The proposed system showed less than 5% error rate when proper moving averages are N=50~60 and a range of thresholds is 800~1300. The system will contribute to preventing suffocation during sleep for infants and the elderly living alone.

Measurement of Apnea Using a Polyvinylidene Fluoride Sensor Inserted in the Pillow (베게에 삽입된 PVDF센서를 이용한 무호흡증 측정)

  • Keum, dong-Wi;Kim, Jeong-Do
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.407-413
    • /
    • 2018
  • Most sleep apnea patients exhibit severe snoring, and long-lasting sleep apnea may cause insomnia, hypertension, cardiovascular diseases, stroke, and other diseases. Although polysomnography is the typical sleep diagnostic method to accurately diagnose sleep apnea by measuring a variety of bio-signals that occur during sleep, it is inconvenient as the patient has to sleep with attached electrodes at the hospital for the diagnosis. In this study, a diagnostic pillow is designed to measure respiration, heart rate, and snoring during sleep, using only one polyvinylidene fluoride (PVDF) sensor. A PVDF sensor with piezoelectric properties was inserted into a specially made instrument to extract accurate signals regardless of the posture during sleep. Wavelet analysis was used to identify the extractability and frequency domain signals of respiration, heart rate, and snoring from the signals generated by the PVDF sensor. In particular, to separate the respiratory signal in the 0.2~0.5 Hz frequency region, wavelet analysis was performed after removing 1~2 Hz frequency components. In addition, signals for respiration, heart rate, and snoring were separated from the PVDF sensor signal through a Butterworth filter and median filter based on the information obtained from the wavelet analysis. Moreover, the possibility of measuring sleep apnea from these separated signals was confirmed. To verify the usefulness of this study, data obtained during sleeping was used.

Development of a multi channel measurement system for the cellular respiration measurement (세포 호흡량 측정용 다채널 측정 시스템 개발)

  • Nam, Hyun-Wook;Park, Jung-Il;KimPak, Young-Mi;Pak, James Jung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.36-42
    • /
    • 2010
  • This paper describes a multi channel measurement system which can measure the cellular respiration level in a solution containing cells by using a Clark-type sensor with the solution temperature control unit. The Clark-type sensor can measure the cellular respiration level in the solution because it can measure the reduction current depending on the dissolved oxygen level in the solution. This measurement system was maintained the temperature within ${\pm}0.1^{\circ}C$ of the setting temperature value by on/off control method in order to measure the precise cellular respiration level. The measurement system showed that the applied voltage to the working electrode was very stable(-0.8 V$\pm$ 0.0071 V) by using proportional control method. From the current measurement, the response time and the linearity correlation coefficient were 25 sec and 0.94, respectively, which are very close to the results of the commercial product. Using this system and the fabricated Clarktype sensor, the average ratio of the uncoupled OCR(oxygen consumption rate) to the coupled OCR was 1.35 and this is almost the same as that obtained from a commercial systems.

The Unconstrained Sleep Monitoring System for Home Healthcare using Air Mattress and Digital Signal Processing (공기 매트리스와 디지털 신호처리를 이용한 홈헬스케어용 무구속 수면 모니터링 시스템)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.493-496
    • /
    • 2005
  • For home healthcare, the unconstrained measurement of physiological signal is highly required to avoid the inconvenience of users. The recording and analysis of the fundamental parameters during sleep like respiration and heart beat provide valuable information on his/her healthcare. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The balancing tube between two air cells is used to increase the robustness against postural changes during the measurement period. The meaningful frequency range could be selected by the pneumatic filter with balancing tube. ECG (Electrocardiography) and respiration sensor (plethysmography) were measured for comparison with the signal from air mattress. To extract the heart beat information from air pressure sensor, digital signal processing technique was used. The accuracy for breathing interval and heart beat monitoring was acceptable. It shows the potentials of air mattress sensor system to be the unconstrained home sleep monitoring system.

  • PDF

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

A Study of the Basic Design for Smart Clothing based on Measurement of the Respiration (호흡 측정 기능의 스마트 의류를 위한 기초 디자인 연구)

  • Cho, Ha Kyung;Min, Se Dong
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.415-424
    • /
    • 2012
  • According to introduction of Well-Being lifestyle and ageing society, vital sign monitoring system which can be continued measurement of vital sign has been increased their important in field of the healthcare. Under this trend, Respiration monitoring system has been studied and developed in a various way to apply continued monitoring and non-conscious monitoring system. But, Study of the respiration monitoring system based on consumer needs and usability test is insufficient. In this study, Textile capacitive pressure sensor(TCPS) of belt type was developed and tested it's utility and subjective sensibility. TCPS measures respiration signals and can be derived in real time monitoring. As a result, monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rate (correlation (r=0.9553, p<0.0001). In the result of usability and wearability test, all of categorizes(perceived change, wearability, movement, facility of management, usefulness) were received favorable evaluation on usability test( mean value : 3.8), and suitable location of TCPS in the clothing is deriven on the abdomen part. According to synthetical results, Basic smart clothing design based on respiration monitoring system is proposed.

  • PDF