• Title/Summary/Keyword: Respiration detection system

Search Result 51, Processing Time 0.025 seconds

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

Characteristics and Fabrication of Dissolved Oxygen and pH Measurement System based on the Optical Sensor for Analysis of Cell Metabolic Functions (세포대사 기능 분석을 위한 광학센서 기반 용존산소와 pH 측정 시스템의 제작 및 특성 분석)

  • Jang, Jiwoon;Hwang, Insook;Lee, Jongmok;Lee, Sunmin;Kang, Sora;Kim Pak, Youngmi;Kim, Nayoung
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.51-56
    • /
    • 2016
  • This study evaluates the performance of an optical sensor and measurement system (CMA-24) which can analyze the fluctuation of dissolved oxygen and pH simultaneously. In the optical sensor system, the fluorescent materials, Rudpp and HPTS which are sensitive to dissolved oxygen and pH, respectively, are coated on the bottom of a 24-well -plate by the sol-gel technology. The detection times of the emission light of the oxygen sensor were $4,186{\pm}13.90{\mu}s$ and $4,452{\pm}36.68{\mu}s$ for the dissolved oxygen of 17% $O_2$ and 7.6% $O_2$, respectively. On the other hand, the detection times of the pH sensor were $6,699.43{\pm}14.64{\mu}s$, $6,722.24{\pm}6.21{\mu}s$, and $6,748.52{\pm}2.63{\mu}s$ using pH 6, 7, and 8, respectively. When we determined cellular respiration levels of C2C12 myocytes with CMA-24, $O_2$/pH measurement system, the ratio of the uncoupled to coupled OCR (oxygen consumption rate) was 1.41. The results mean that this CMA-24 system shows almost the same sensitiveness as the commercial system.

Development of Cyanide Sensor Using S. cerevisiae (S. cerevisiae를 이용한 시안센서의 개발)

  • 김종민;이현우
    • KSBB Journal
    • /
    • v.11 no.6
    • /
    • pp.669-675
    • /
    • 1996
  • Two types of cyanide sensor system were constructed for monitoring river water simply. One is membrane type flow system composed of S. cerevisiae coated membrane and oxygen electrode, the other is reactor type flow system composed of S. cevevisiae immobilized reactor and two oxygen electrode. S. cerevisiae and oxygen electrode were used for detecting cyanide compounds. These sensors are based on the inhibition of cyanides on the respiration activity of S. cerevisiae. Membrane type sensor system could detect cyanides ranging 0.10∼1.00ppm, and the respiration activity of S. cerevisiae continued for a day. Reactor type sensor system composed of immobilized chitopearl HP-5020 with S. cerevisiae could detect cyanides in the range of 0.10∼1.00ppm, and maintained 90% respiration activity for sixteen days. It was found that the optimum reactor size exist for the reactor type biosensor when respirating activity inhibition is used for detection of cyanides.

  • PDF

Detection of Heartbeat and Respiration Signal Using the Aircushion and the Frequency Domain Filter (에어쿠션 및 주파수 영역 필터를 이용한 호흡 및 심박 신호 검출)

  • Kim, Joo-Han;Cho, Sung-Pil;Shin, Jae-Yeon;Lee, Jeon;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.5
    • /
    • pp.33-42
    • /
    • 2010
  • In this study, we have proposed a simple cardiorespiratory monitoring method based on displacements of human body which occurs due to periodic heartbeat and breathing. The proposed system consists of an aircushion, pressure sensing hardware and heartbeat and respiration signals extraction algorithm. The aircushion was used for unconstrained measurement of the respiration and heartbeats without a sensor attached on the subject's skin surface. The displacements of subject sitting on the aircushion cause small pressure variations. These variations are amplified and filtered with the pressure sensing hardware. Finally, heart rate and respiration rate are extracted by signal processing algorithm based on frequency domain filter. To evaluate the performance, extracted respiration and heart rate from proposed system were compared with conventional methods. The average sensitivity of respiration and heart rate are 98.67% and 99.24%, respectively. These results show the proposed method has advantages of installing and processing simplicity so as to be used easily in unconstrained respiration and heart rate monitoring in daily life.

Real-Time Respiration and Heartbeat Detector Using a Compact 1.6 GHz Single-Channel Doppler Sensor (소형화된 1.6 GHz 단일 채널 도플러 센서를 이용한 실시간 호흡 및 심장 박동 감지기)

  • Lee, Hyun-Woo;Park, Il-Ho;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.379-388
    • /
    • 2007
  • This paper presents a real-time respiration and heartbeat detector comprised of a 1.6 GHz single-channel Doppler sensor and analog/digital signal processing block for remote vital sign detection. The RF front end of the Doppler sensor consists of an oscillator, mixer, low noise amplifier, branch-line hybrid and patch antenna. We apply artificial transmission lines(ATLs) to the branch-line hybrid, which leads to a size reduction of 40 % in the hybrid, while its performance is very comparable to that of a conventional hybrid. The analog signal conditioning block is implemented using second order Sallen-Key active filters and the digital signal processing block is realized with a LabVIEW program on a computer. The respiration and heartbeat detection is demonstrated at a distance of 50 cm using the developed system.

Robust Design of Pulse Oximeter Using Dynamic Control and Motion Artifact Detection Algorithms

  • Cho, Jung Hyun;Kim, Jong Cheol;Yoon, Gil Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1780-1787
    • /
    • 2014
  • Arterial oxygen saturation ($SpO_2$) monitoring for newborns requires special attention in neonatal intensive care units (NICUs). Newborns have very low photo-plethysmogram (PPG) amplitudes and their body movements are difficult to contain. Hardware design and its associated signal processing algorithms should be robust enough so that faulty measurements can be avoided. In this study, improved designs were implemented to deal with low perfusion, motion artifact, and the influence of ambient light. Dynamic range was increased by using different LED intensities and a feedback system. To minimize the effects of motion artifact and to discard other unqualified data, four additional algorithms were used, which were based on dual-trace detection, continuity of DC level, morphology of PPG, and simultaneity check of $SpO_2$. Our $SpO_2$ system was tested with newborns with normal respiration in the NICU. Our system provided fast, real-time responses and 100% artifact detection was accomplished under 84% of $SpO_2$.

Development of Data Acquisition System for Quantification of Autonomic Nervous System Activity and It's Clinical Use (자율신경계의 활성도 측정을 위한 Data Acquisition System의 개발 및 임상응용)

  • Shin, Dong-Gu;Park, Jong-Sun;Kim, Young-Jo;Shim, Bong-Sup;Lee, Sang-Hak;Lee, Jun-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • Background: Power spectrum analysis method is a powerful noninvasive tool for quantifying autonomic nervous system activity. In this paper, we developed a data acquistion system for estimating the activity of the autonomic nervous system by the analysis of heart rate and respiratory rate variability using power spectrum analysis. Materials and methods: For the detection of QRS peak and measurement of respiratory rate from patient's ECG, we used low-pass filter and impedence method respectively. This system adopt an isolated power for patient's safety. In this system, two output signals can be obtained: R-R interval heart rate) and respiration rate time series. Experimental ranges are 30-240 BPM for ECG and 15-80 BPM for respiration. Results: The system can acquire two signals accurately both in the experimental test using simulator and in real clinical setting. Conclusion: The system developed in this paper is efficient for the acquisition of heart rate and respiration signals. This system will play a role in research area for improving our understanding of the pathophysiologic involvement of the autonomic nervous system in various disease states.

  • PDF

A Study on Database for Pulse Rate Diagnosis

  • S. C. Han;Kim, H. K.;Lee, Y. D.;W. Huh;Park, Y. B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.539-542
    • /
    • 1998
  • In this paper, we devised pulse rate diagnosis database system for provide basic index of Cold-Hot diagnosis. The system consist of database part and pulse rate detection part that for detection pulse wave, respiration and ECG. The database is constructed windows95 platform using DAO(Data Access Object). Search algorithm used ISAM algorithm. The database consist of patient information and medical report for a subject and detected biological signals.

  • PDF

A study on database for pulse rate diagnosis (맥율진단을 위한 데이터베이스에 관한 연구)

  • Han, S.C.;Kim, K.K.;Lee, Y.D.;Park, Y.B.;Huh, W.
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.569-572
    • /
    • 1998
  • In this paper, we devised pulse rate diagnosis for provide basic index of cold-hot diagnosis. The system consist of database part and pulse rate detection part for detection pulse wave, respiration and ECG. The database is constructed windwos95 platform using DAO(data access object). Search algorithm used ISAM algorithm. The database consist of one's information and medical report for a subject and detected pulse wave.

  • PDF

Detection of Human Vital Signs and Estimation of Direction of Arrival Using Multiple Doppler Radars

  • An, Yong-Jun;Jang, Byung-Jun;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.250-255
    • /
    • 2010
  • This paper presents a non-contact measurement method of vital signal by the use of multiple-input multiple-output (MIMO) bio-radar system, configured with two antennas that are separated by a certain distance. The direction of arrival (DOA) estimation algorithm for coherent sources was applied to detect vital signals coming from different spatial angles. The proposed MIMO bio-radar system was composed of two identical transceivers sharing single VCO with a PLL. In order to verify the performance of the system, the DOA estimation experiment was completed with respect to the human target at angles varying between $-50^{\circ}$ and $50^{\circ}$ where the bio-radar system was placed at distances (corresponding to 50 cm and 95 cm) in front of a human target. The proposed MIMO bio-radar system can successfully find the direction of a human target.