• Title/Summary/Keyword: Respiration detection

Search Result 86, Processing Time 0.028 seconds

Detection Scheme of Heart and Respiration Signals for a Driver of Car with a Doppler Radar (도플러 레이더 기반 차량 운전자의 심박 및 호흡 신호 검출 기법 연구)

  • Yun, Younguk;Lee, Jeongpyo;Kim, Jinmyung;Kim, Youngok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.87-95
    • /
    • 2020
  • Purpose: In this paper, we propose an algorithm for detecting respiratory rate and heart beat of a driver of car by exploiting Doppler radar, and verifying the feasibility of the study through experiments. Method: In this paper, we propose a weighted peak detection technique using peak frequency values. The tests are performed in stop-state and driving-state, and the experiment result is analyzed by two proposed algorithms. Result: The results showed more than 95% and 96% accuracy of respiratory and heart rate, respectively. It also showed more than 72% and 84% accuracy of those even for driving experiments. Conclusion: The proposed detection scheme for vital signs can be used for the safety of the driver as well as for prevention of a large size of car accidents.

Snoring Detection Sleep Pillow (코골이 감지 수면베개)

  • Tran, Minh;Ahn, Dohyun;Park, Jaehee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.20 no.2
    • /
    • pp.105-110
    • /
    • 2019
  • People sleep about one-third of their lives and their sleep time varies according to age. Adult usually sleep 8 hours a day. However, that dose not guarantee good sleep. The cause of this is due to sleep disorders like snoring and sleep apnea. In this paper, the smart pillow for detecting snoring among sleep disorders is investigated. This pillow consists of two microphones located on the left and right side of the pillow. For simple detecting, the snoring signal was converted into the pulse using a peak detection circuit. The decision of the snoring occurrence was by pulse duration. The accuracy of the snoring detection was about 97%. The research results show that the smart pillow can be use to detect the snoring during sleeping.

Unconstrained detection of Heart Rate and Respiration using PPG sensor (PPG 센서를 이용한 심박 및 호흡 신호의 무구속적 검출에 대한 연구)

  • Cha, Ji-Young;Choi, Hyun-Seok;Shin, Jae-Yeon;Lee, Kyoung-Joung
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.482-483
    • /
    • 2008
  • 본 연구는 수면 중 무구속적 방식으로 에어 베개에 부착한 PPG 센서에서 호흡 및 심박을 검출하는 방법을 제안하였다. 본 연구에서 사용된 반사형 PPG 센서는 광원이 피부로 투과되어 혈관의 이완 및 수축 정도를 측정할 수 있다. 반사형 PPG 센서로부터 하드웨어 모듈을 통과한 생체 신호는 AD 변환되어 PC로 전송된다 PPG에서 검출된 분당 심박 수는 전송된 신호의 밸리점간의 시간 간격을 이용하여 추출하며 호흡 신호는 밸리점의 크기를 연결하여 추출하였다. 검출된 호흡 신호와 기준 호흡 신호간의 상관성을 확인하기 위해 기준신호로 호흡과 심박을 동시에 측정하여 그 결과를 분석하였다. PPG 센서로부터 획득한 심박 및 호흡 신호는 기준신호들과 높은 상관성을 가지며 호흡시 발생하는 움직임과 호흡 속도에 영향을 받는다는 것을 알 수 있었다.

  • PDF

Noncontact Heartbeat and Respiration Detection Algorithm Using FFT (FFT를 이용한 비접촉 방식의 심박 및 호흡검출 알고리즘)

  • Oh, Seung-Lee;Kim, Han-Jin;Jang, Young-Beom
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05b
    • /
    • pp.583-585
    • /
    • 2011
  • 이 논문에서는 비접촉 방식의 심박 및 호흡 검출이 가능한 FFT를 이용하는 새로운 검출 방식의 알고리즘을 제안한다. 기존 FFT 방식은 주파수 도메인에서 필터링을 수행한 후 IFFT 후 특징점 추출 알고리즘을 수행하여 심박 및 호흡을 추출한다. 이 논문에서는 제안된 FFT 방식을 사용하여 기존의 FFT 방식과 달리 FFT를 한 후 주파수 영역에서 바로 심박수 및 호흡수를 추출할 수 있음을 제안한다.

  • PDF

Detection of Human Vital Signs and Estimation of Direction of Arrival Using Multiple Doppler Radars

  • An, Yong-Jun;Jang, Byung-Jun;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.250-255
    • /
    • 2010
  • This paper presents a non-contact measurement method of vital signal by the use of multiple-input multiple-output (MIMO) bio-radar system, configured with two antennas that are separated by a certain distance. The direction of arrival (DOA) estimation algorithm for coherent sources was applied to detect vital signals coming from different spatial angles. The proposed MIMO bio-radar system was composed of two identical transceivers sharing single VCO with a PLL. In order to verify the performance of the system, the DOA estimation experiment was completed with respect to the human target at angles varying between $-50^{\circ}$ and $50^{\circ}$ where the bio-radar system was placed at distances (corresponding to 50 cm and 95 cm) in front of a human target. The proposed MIMO bio-radar system can successfully find the direction of a human target.

DSP Embeded Hardware for Non-contact Bio-radar Heart and Respiration Rate Monitoring System (DSP를 이용한 비 접촉식 도플러 바이오 레이더 생체신호 모니터링 시스템 임베디드 하드웨어의 개발)

  • Kim, Jin-Seung;Jang, Byung-Jun;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.97-104
    • /
    • 2010
  • In this paper, we provide an embedded type non-contact bio-radar heart and respiration rate monitoring system. We implemented the rate finding algorithm into the embedded system. The high-speed and reliable real-time signal processor is then tested. To avoid null-point data loss problem, we applied quadrature demodulation. Among several other combining techniques, we suggest arctangent demodulation for quadrature channel combining and DSP is used for real-time signal processing. We also suggest DC-offset compensation technique to preserve the wanted DC components of the IQ signals for accurate demodulation while keeping the dynamic range of the ADC lower. Using Texas Instrument C6711 series DSP and external 12Bit ADC, we implemented proper elliptic digital filter and autocorrelation detection algorithm for robust commercial hand held device.

Non-Contact Vital Signal Sensor Based on Impedance Variation of Resonator (공진기의 임피던스 변화에 근거한 비접촉 생체 신호 센서)

  • Kim, Kee-Yun;Kim, Sang-Gyu;Hong, Yunseog;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.9
    • /
    • pp.813-821
    • /
    • 2013
  • In this paper, a vital signal sensor based on impedance variation of resonator is presented. Proposed vital signal sensor can detect the vital signal, such as respiration and heart-beat signal. System is composed of resonator, oscillator, surface acoustic wave (SAW) filter, and power detector. The cyclical movement of a dielectric such as a human body, causes the impedance variation of resonator within the near-field range. So oscillator's oscillation frequency variation is effected on resonator's resonant frequency. SAW filter's skirt characteristic of frequency response can be transformed a small amount of frequency deviation to a large variation. Aim to enhance the existing sensor detection range, proposed sensor operates in 870 MHz ISM band, and detect respiration and heart-beat signal at distance of 120 mm.

Development of Humidity Sensor Based on Ceramic/Metal Halide Composite Films for Non-Contact Biological Signal Monitoring Applications (비접촉 생체신호 모니터링 응용을 위한 세라믹/메탈 할라이드 복합막 기반 습도센서 개발)

  • Park, Tae-Ung;Kim, Ik-Soo;Kim, Min-Ji;Park, Chulhwan;Seo, Eui-kyoung;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.412-417
    • /
    • 2022
  • Capacitive-type humidity sensors with a high sensitivity and fast response/recovery times have attracted a great attention in non-contact respiration biological signal monitoring applications. However, complicated fabrication processes involving high-temperature heat treatment for the hygroscopic film is essential in the conventional ceramic-based humidity sensors. In this study, a non-toxic ceramic/metal halide (BaTiO3(BT)/NaCl) humidity sensor was prepared at room temperature using a solvent-free aerosol deposition process (AD) without any additional process. Currently prepared BT/NaCl humidity sensor shows an excellent sensitivity (245 pF/RH%) and superior response/recovery times (3s/4s) due to the NaCl ionization effect resulting in an immense interfacial polarization. Furthermore, the non-contact respiration signal variation using the BT/NaCl sensor was determined to be over 700% by maintaining the distance of 20 cm between the individual and the sensor. Through the AD-fabricated sensor in this study, we expect to develop a non-contact biological signal monitoring system that can be applied to various fields such as respiratory disease detection and management, infant respiratory signal observation, and touchless skin moisture sensing button.

Doppler Radar System for Long Range Detection of Respiration and Heart Rate (원거리에서 측정 가능한 호흡 및 심박 수 측정을 위한 도플러 레이더 시스템)

  • Lee, Jee-Hoon;Kim, Ki-Beom;Park, Seong-Ook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.4
    • /
    • pp.418-425
    • /
    • 2014
  • This paper presents a Ku-Band Doppler Radar System to measure respiration and heart rate. It was measured by using simultaneous radar and ECG(Electrocardiogram). Arctangent demodulation without dc offset compensation can be applied to transmitted I/Q(In-phase & Quadrature-phase) signal in order to improve the RMSE(Root Mean Square Error) about 50 %. The power leaked to receiving antenna from the transmitting antenna is always generated because of continuously opening the transceiver of CW(Continuous Wave) Doppler radar. As the output power increase, leakage power has an effect on the SNR(Signal-to-Noise Ratio) of the system. Therefore, in this paper, leakage cancellation technique that adds the signal having the opposite phase of the leakage power to the leakage power was implemented in order to minimize the decline of receiver sensitivity. By applying the leakage cancellation techniques described above, it is possible to measure the heart rate and respiration of the human at a distance of up to 35 m. the heart rate of the measured data at a distance of 35 m accords with the heart rate extracted from the ECG data.

Design of FMCW Radar Signal Processor for Human and Objects Classification Based on Respiration Measurement (호흡 기반 사람과 사물 구분 가능한 FMCW 레이다 신호처리 프로세서의 설계)

  • Lee, Yungu;Yun, Hyeongseok;Kim, Suyeon;Heo, Seongwook;Jung, Yunho
    • Journal of Advanced Navigation Technology
    • /
    • v.25 no.4
    • /
    • pp.305-312
    • /
    • 2021
  • Even though various types of sensors are being used for security applications, radar sensors are being suggested as an alternative due to the privacy issues. Among those radar sensors, PD radar has high-complexity receiver, but, FMCW radar requires fewer resources. However, FMCW has disadvantage from the use of 2D-FFT which increases the complexity, and it is difficult to distinguish people from objects those are stationary. In this paper, we present the design and the implementation results of the radar signal processor (RSP) that can distinguish between people and object by respiration measurement using phase estimation without 2D-FFT. The proposed RSP is designed with Verilog-HDL and is implemented on FPGA device. It was confirmed that the proposed RSP includes 6,425 LUT, 4,243 register, and 12,288 memory bits with 92.1% accuracy for target's breathing status.