Browse > Article

DSP Embeded Hardware for Non-contact Bio-radar Heart and Respiration Rate Monitoring System  

Kim, Jin-Seung (School of Electronic Engineering, Kookmin University)
Jang, Byung-Jun (School of Electronic Engineering, Kookmin University)
Kim, Ki-Doo (School of Electronic Engineering, Kookmin University)
Publication Information
Abstract
In this paper, we provide an embedded type non-contact bio-radar heart and respiration rate monitoring system. We implemented the rate finding algorithm into the embedded system. The high-speed and reliable real-time signal processor is then tested. To avoid null-point data loss problem, we applied quadrature demodulation. Among several other combining techniques, we suggest arctangent demodulation for quadrature channel combining and DSP is used for real-time signal processing. We also suggest DC-offset compensation technique to preserve the wanted DC components of the IQ signals for accurate demodulation while keeping the dynamic range of the ADC lower. Using Texas Instrument C6711 series DSP and external 12Bit ADC, we implemented proper elliptic digital filter and autocorrelation detection algorithm for robust commercial hand held device.
Keywords
Arctangent combining; Embedded system; DC-offset compensation;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Byung-Kwon Park, O. B. Lubecke and V. M. Lubecke, "Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems," IEEE Transactions On Microwave Theory and Techniques, vol. 55, no. 5, pp. 1073-1079, MAY 2007.   DOI
2 R. Moraes and D. H. Evans, "Compensation for phase and amplitude imbalance in quadrature Doppler signals," Ultrasound Med. Biol., vol. 22, pp. 129-137, 1996.   DOI   ScienceOn
3 Yong-Jin Lee, Byung-Jun Jang, Jong-Gwan Yook, "호흡 및 심박수 측정을 위한 비 접촉 방식의 2.4 GHz바이오 레이더 시스템," 한국전자공학회 논문지, 제 19 권, 제 2 호, pp. 191-198, 2008 2월.   과학기술학회마을
4 A. D. Droitcour, "Non-contact measurement of heart and respiration rates with a single-chip microwave doppler radar," Ph.D Dissertation, Stanford University, 2006.
5 강성욱, 이성호, "유헬스의 경제적 효과와 성장전략," 삼성경제연구소, Issue paper 2007년 7월.
6 J. Muehlsteff, J. Thijs, R. Pinter, G. Morren, G. Muesch, "A handheld device for simultaneous detection of electrical and mechanical cardio -vascular activities with synchronized ECG and CW-Doppler Radar," IEEE EMBS Cit Internationale, Lyon, France August 23-26, 2007.
7 American Heart Association, "Heart beat signal recognition," US Patent 20090043216.
8 John C. Lindon, Jeremy K. Nicholson, Elaine Holmes, "The handbook of metabonomics and metabolomics," Elsevier, p. 203, 2007.
9 Mohammad Shaifur Rahman, Jin-Seung Kim, Byung-Jun Jang, and Ki-Doo Kim, "A New Digital Signal Processor for Doppler Radar Cardiopulmonary Monitoring System," ICECE 2008, Dhaka, December 2008.
10 Mohammad Shaifur Rahman, Byung-Jun Jang, and Ki-Doo Kim, "Quadrature Channel Combining for Doppler Radar Cardiopulmonary Monitoring System," UKC2008, San Diego, August 2008.