• Title/Summary/Keyword: Respirable dust

Search Result 89, Processing Time 0.032 seconds

Relationships between a Calculated Mass Concentration and a Measured Concentration of PM2.5 and Respirable Particle Matter Sampling Direct-Reading Instruments in Taconite Mines (타코나이트 광산 공정에서의 실시간 질량측정기기와 실시간 수농도의 환산에 의한 질량농도와의 연관성)

  • Chung, Eun-Kyo;Jang, Jae-Kil;Song, Se-Wook;Kim, Jeongho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.65-73
    • /
    • 2014
  • Objectives: The purposes of this study are to investigate workers' exposures to respirable particles generated in taconite mines and to compare two metric methods for mass concentrations using direct-reading instruments. Methods: Air monitorings were conducted at six mines where subjects have been exposed primarily to particulate matters in crushing, concentrating, and pelletizing processes. Air samples were collected during 4 hours of the entire work shift for similarly exposure groups(SEGs) of nine jobs(N=37). Following instruments were employed to evaluate the workplace: a nanoparticle aerosol monitor(particle size range; 10-1000 nm, unit: ${\mu}m^2/cc$, Model 9000, TSI Inc.); DustTrak air monitors($PM_{10}$, $PM_{2.5}$, unit: $mg/m^3$, Model 8520, TSI Inc.); a condensation particle counter(size range; 20-1000 nm, unit: #/cc, P-Trak 8525, TSI Inc.); and an optical particle counter(particle number by size range $0.3-25{\mu}m$, unit: #/cc, Aerotrak 9306, TSI Inc.). Results: The highest airborne concentration among SEGs was for furnace operator followed by pelletizing maintenance workers in number of particle and surface area, but not in mass concentrations. The geometric means of $PM_{2.5}$ by the DustTrak and the Ptrak/Aerotrak were $0.04{\mu}m$(GSD 2.52) and $0.07{\mu}m$(GSD 2.60), respectively. Also, the geometric means of RPM by the DustTrak and the Ptrak/Aerotrak were $0.16{\mu}m$(GSD 2.24) and $0.32{\mu}m$(GSD 3.24), respectively. The Pearson correlation coefficient for DustTrak $PM_{2.5}$ and Ptrak/Aerotrak $PM_{2.5}$ was 0.56, and that of DustTrak RPM and Ptrak/Aerotrak RPM was 0.65, indicating a moderate positive association between the two sampling methods. Surface area and number concentration were highly correlated($R^2$ = 0.80), while $PM_{2.5}$ and RPM were also statistically correlated each other($R^2$ = 0.79). Conclusions: The results suggest that it is possible to measure airborne particulates by mass concentrations or particle number concentrations using real-time instruments instead of using the DustTrak Aerosol monitor that monitor mass concentrations only.

The concentrations of airborne dust in non-metallic products factories and problems associated with the application of the occupational exposure limits (비금속광물 제품제조업에서 발생하는 분진 농도와 분진 노출기준 적용에 따른 문제점 고찰)

  • Kim, Hyunwook;Phee, Young Gyu;Won, Jung Il;Ko, Won Kyung;Roh, Young Man;Shin, Chang Sub
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.104-114
    • /
    • 2000
  • This study was carried out to estimate current status of dust concentrations in the factories producing non-metallic products in Korea. Data were gathered from the environmental monitoring reports by 40 workplace environmental monitoring institutes and the questionnaire designed for the study by the authors. A total of 1838 dust samples from 368 plants were obtained from the reports and were analyzed with no data modifications. But data on asbestos, rock wool, and welding fumes were excluded in this evaluation. The factories were classified into eight groups according to the standard industrial classification scheme in Korea. The results of this study were as follows; 1. The factories included were glass, non-refractory ceramic, refractory ceramic ware, structural non-refractory clay and ceramic, cement and lime, articles of concretes, and stone. Mean(geometric mean) concentrations of total dust samples ranged from $1.75(0.84)mg/m^3$ to $5.87(2.84)mg/m^3$. Statistically significantly higher dust concentrations were found in the cement and lime industries compared with other industries. 2. The non-compliance rates were 15.2% in glass and 20.6% in other non-metallic mineral products industries. Although all institutions surveyed utilized the identical sampling and classification scheme for dusts as specified in the current occupational exposure limits, wide discrepancies were found in collecting samples and classifying dusts. Further problems were discovered in classifying dusts. A dust sample collected could be classified into any of the three groups regardless of silica content. The results of this study showed that dust concentrations in the non-metallic products industries varied widely. Also discovered was classification errors of dust types among workplace monitoring institutes. These errors could adversely affect the results of exposure assessments and the true nature of dust hazards. Further, no institutions performed respirable dust sampling and analysis of crystalline silica. In order to correct these malpractices, current standards of occupational exposure limits should be revised and tight supervision by the Ministry of Labour be suggested.

  • PDF

Investigation on Generation and Emission of Particulate Matters and Ammonia from Mechanically-ventilated Layer House (강제환기식 산란계 사육시설의 PM, NH3 발생·배출 특성 조사)

  • Jang, Dong-Hwa;Yang, Ka-Young;Kwon, Kyeong-Seok;Kim, Jong-Bok;Ha, Tae-Hwan;Jang, Yu-Na
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.1
    • /
    • pp.99-110
    • /
    • 2022
  • In this study, the generation and emission characteristics of particulate matter and gaseous matter in a mechanically ventilated layer house were evaluated. Each concentration of PM10, PM2.5, inhalable dust, respirable dust, and NH3 was measured and compared with occupational limit considering seasons and respiratory disorder. CAPPS (Clean Air Policy Support System) of the Ministry of Environment proposes the emission factors of PM10, PM2.5, and NH3 for a layer houses however, emission factors are still calculated from foreign factors such as CONINAIR values. As a result, it is urgent to develop national emission factors for domestic layer house. Emission coefficients of the studied mechanically-ventilated layer house in a summer season were calculated as 0.052 kg/head/year for PM10, about 12% lower than that of CAPSS, and 0.0068±0.0038 kg/head/year for PM2.5, showing no significant difference. Emission factor of NH3 was calculated as 0.159±0.031 kg/head/year, about 51% lower than that of CAPSS.

A Studs on Exposure to Organic Dust and Ammonia in Poultry Confinement Buildings (일부 육용 양계 농업인의 유기먼지와 암모니아 노출에 관한 연구)

  • Shin, Cheol-Lim;Lee, Kyung-Suk;Kim, Kyung-Ran;Kang, Tae-Sun;Paik, Nam-Won
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.2
    • /
    • pp.303-314
    • /
    • 2004
  • Objectives: This study was carried out to assess exposure levels of organic dusts and ammonia in poultry farms in Korea. Methods: A total of six poultry farms were investigated. The farms were located in Namwon, Chonlabuk-do and in Kae-San, Chungchongbuk-do. This study consisted of a questionnaire and measuring organic dusts and ammonia. The questionnaire included the characteristics of the farms, work patterns and the tasks of the poultry farms. Results and Conclusions: The farmers raised the chickens 45 times a year and the average number of years in the poultry farm were eight years ranging from 2 to 12 years. They worked for seven days per week and the average hours spent caring the chickens are 6.3 hours per day. The duration of staying in the confinement buildings was 3.3 hours per day. The work time in summer was longest. The feed and the water supply systems were automatic and the control of ventilation windows used "winch curtain" was semiautomatic. They used mechanical ventilation system in winter and used dilution ventilation system in the other seasons. The geometric mean concentration of total and respirable dust sampled in the poultry confinement buildings was 4.0 mg/$m^3$and 0.9 mg/$m^3$ respectively. The ratio of respirable to total dusts range from 9 to 49 percent. There was no sample exceeding the criteria 10 mg/$m^3$ for total dust and 3 mg/$m^3$ for respirable dust in farms. The criteria have been recommended by Korean Ministry of Labor and American Conference of Governmental Industrial Hygienist. The personal respirable dusts measured during a circle work averaged geometric mean concentration 1.4 mg/$m^3$ Two personal samples were exceeded the threshold 3 mg/$m^3$. There was a positive relation between an index and the personal samples of respirable dusts($R^2$=0.98). The index is calculated by multipling the total number of chickens in the farm by the age of the chickens and then dividing by the volume of the confinement building. The geometric mean concentration of area and personal ammonia samples was 23.3 ppm and 22.2 ppm, respectively. Some of the ammonia samples, both area and personal samples, exceeded the short term exposure limit value 35 ppm.

  • PDF

Investigation and Analysis of Particulate-matters and Ammonia Concentrations in Mechanically Ventilated Broiler House According to Seasonal Change, Measurement Locations and Age of Broilers (강제환기식 육계 사육시설의 계절별, 지점별, 주령별 PM, NH3 농도 조사 및 분석)

  • Jang, Dong-hwa;Kwon, Kyeong-seok;Kim, Jong-bok;Kim, Jung-kon;Yang, Ka-young;Choi, Sung-min;Jang, YuNa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.63 no.1
    • /
    • pp.75-87
    • /
    • 2021
  • Air quality related to particulate matters and ammonia is being come to the fore as the national concern in Korea. CAPSS (Clean Air Policy Support System) provides emission coefficients of these kinds of particulate and gaseous matters in the fields of livestock; however reliability issues are consistently mentioned. Evaluation of emission rates of PM2.5 and NH3 of the country is very important, but only few studies are available as the background related to observation of the concentration of the particulate matter and ammonia, especially within livestock house in Korea. In this paper, long-term measurement of PM10, PM2.5, and ammonia within the mechanically ventilated broiler house were carried out to introduce backgrounds of generation and emission of the particulate matters and ammonia. Measurement results were analyzed according to seasonal changes, age of broilers(weeks) and measurement locations. Concentration of inhalable and respirable dust were also evaluated in terms of occupational respiratory health according to increase in broiler's activity. From the results of this study, identification of the generation mechanisms of the particulate and gaseous matters, and evaluation of the emission rate of these in the broiler house will be carried out.

Measurement of Airborne Particles and Volatile Organic Compounds Produced During the Heat Treatment Process in Manufacturing Welding Materials

  • Myoungho Lee;Sungyo Jung;Geonho Do;Yeram Yang;Jongsu Kim;Chungsik Yoon
    • Safety and Health at Work
    • /
    • v.14 no.2
    • /
    • pp.215-221
    • /
    • 2023
  • Background: There is little information about the airborne hazardous agents released during the heat treatment when manufacturing a welding material. This study aimed to evaluate the airborne hazardous agents generated at welding material manufacturing sites through area sampling. Methods: concentration of airborne particles was measured using a scanning mobility particle sizer and optical particle sizer. Total suspended particles (TSP) and respirable dust samples were collected on polyvinyl chloride filters and weighed to measure the mass concentrations. Volatile organic compounds and heavy metals were analyzed using a gas chromatography mass spectrometer and inductively coupled plasma mass spectrometer, respectively. Results: The average mass concentration of TSP was 683.1±677.4 ㎍/m3, with respirable dust accounting for 38.6% of the TSP. The average concentration of the airborne particles less than 10 ㎛ in diameter was 11.2-22.8×104 particles/cm3, and the average number of the particles with a diameter of 10-100 nm was approximately 78-86% of the total measured particles (<10 ㎛). In the case of volatile organic compounds, the heat treatment process concentration was significantly higher (p < 0.05) during combustion than during cooling. The airborne heavy metal concentrations differed depending on the materials used for heat treatment. The content of heavy metals in the airborne particles was approximately 32.6%. Conclusions: Nanoparticle exposure increased as the number of particles in the air around the heat treatment process increases, and the ratio of heavy metals in dust generated after the heat treatment process is high, which may adversely affect workers' health.

Exposure Assessment of Dust, Ultra Fine Dust(Particulate Matter 2.5, PM2.5) and Black Carbon among Aircraft Cabin Cleaners (항공기 기내 청소노동자의 분진, 초미세먼지(PM2.5) 및 블랙카본 노출수준 평가)

  • Hyunhee Park;Sedong Kim;Sungho Kim;Seung-Hyun Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • Objectives: Aircraft cabin cleaning work is characterized by being performed within a limited time in a narrow and enclosed space. The objective of this study was to evaluate the exposure levels to dust, ultra fine dust(PM2.5) and black carbon(BC) among aircraft cabin cleaners. Methods: Active personal air sampling for respirable dust(n=73) and BC(n=47) was conducted during quick transit cleaning(cabin general and vacuum-specific) and seat cover replacement and total dust and PM2.5 were area-air-sampled as well. Also, size distribution of particle was identified with the cleaning workers targeted. Dusts were collected with PVC filters using gravimetric analysis. The concentration of PM2.5 and the particle size distribution were measured with real-time direct reading portable equipment using light scattering analysis. The concentration of BC was measured by aethalometer(filter-based real-time light absorption analysis instrument). Results: The geometric mean of respirable dust was the highest at vacuum cleaning as 74.4 ㎍/m3, following by replacing seat covers as 49.3 ㎍/m3 and cabin general cleaning as 47.8 ㎍/m3 . The arithmetic mean of PM2.5 was 4.83 ~ 9.89 ㎍/m3 inside the cabin, and 28.5~44.5 ㎍/m3 outside the cabin(from bus and outdoor waiting space). From size distribution, PM2.5/PM10 ratio was 0.54 at quick transit cleaning and 0.41 at replacing seat covers. The average concentration of BC was 2~7 ㎍/m3, showing a high correlation with the PM2.5 concentration. Conclusions: The hazards concentration levels of aircraft cabin cleaners were very similar to those of roadside outdoor workers. As the main source of pollution is estimated to be diesel vehicles operating at airports, and it is necessary to replace older vehicles, strengthen pollutant emission control regulations, and introduce electric vehicles. In addition, it is necessary to provide as part of airport-inftastructure a stable standby waiting space for aircraft cabin cleaners and introduce a systematic safety and health management system for all workers in the aviation industry.

Dust Concentration Monitoring in Korean Native Cattle Farm according to Sampling Location and TMR Process (한우사 내부 위치 및 TMR 배합 작업에 따른 분진 모니터링)

  • Park, Gwanyong;Kwon, Kyeong-Seok;Lee, In-bok;Yeo, Uk-Hyeon;Lee, Sang-Yeon;Kim, Jun-Gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.4
    • /
    • pp.75-83
    • /
    • 2017
  • Many parts of problems in livestock industry today are associated with organic dust. Endotoxin and toxic gasses on the surface of dust and dust itself can cause aesthetic displeasure and respiratory disease. It also reduces livestock productivity by suppressing immunity of animals and carrying microbes causing animal disease. However, dust level of cattle farm was rarely reported in Korea, and regulation for cattle farm worker does not exist. In this paper, dust concentration and environmental condition were regularly monitored in a commercial Korean native cattle farm. The measurement was conducted according to location and working activities. From the measurement, distribution of dust concentration was affected by wind environment, as the result of natural ventilation. TMR mixer was a major source of dust in target cattle house. The maximum inhalable dust concentration was 637.8 times higher than exposure limit as feed dropped into the TMR mixer. It was expected that dust generation could be affected by particle size and drop height of feed. This study suggests potential risk of dust in cattle farm, and necessity for latter study. Effect of aerodynamic condition and TMR processing should be investigated for dust reduction study.

Exposure Assessment of Airborne Cobalt in Manufacturing Industries (코발트 취급사업장의 공기 중 코발트 노출평가)

  • Kim, Jae Hong;Jung, Jong-Hyon;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.2
    • /
    • pp.166-173
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate cobalt concentrations in airborne inhalable, total and respirable dust from manufacturing industries using cobalt. Methods: To compare cobalt concentrations, three types of dust samplers(a 37mm closed cassette sampler, Institute of Occupational Medicine(IOM) sampler, and Aluminum cyclone sampler) were used. The analysis of cobalt concentrations was conducted using AAs based on the NIOSH 7300 method. Results: The geometric mean of cobalt concentration in total dust was $1.47{\mu}g/m^3$, and the rate of excess of the Korean Occupational Exposure Limit(KOEL) was 10.0%. The geometric mean concentrations of cobalt in super alloy manufacturing industries were higher than those in plating industries, and molding operations showed higher exposure levels to cobalt than did other operations. Conclusions: The rate of cobalt concentration in inhalable dust from super alloy manufacturing industries exceeding the Workplace Exposure Limit(WEL) as recommended by the Health & Safety Executive(HSE) was 7.1%, which means proper work environmental management is required through wet work environments. Given that molding operations had higher cobalt concentrations, it is necessary to apply measures such as local exhaust for reducing airborne dust in cobalt manufacture industries.

The Application of Surfactants to the Suppression of Fugitive Dust Generated from the Scrap Metal Loading Field in Inchon Port and Preliminary Evaluation on Their Wetting Capability (인천항 고철 하역 작업시 발생하는 비산분진 억제를 위한 계면활성제의 적용 및 기초 성능 평가)

  • Lee, Bo-Young;Yoo, Yong-Ho;Jung, Yong-Won;Kim, Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.85-96
    • /
    • 2001
  • The objective of this study is to develop the water spraying which can effectively by applied to the control or suppression of the fugitive dust generated from the scrap metal handling area at the Port of Inchon. As a first step toward this goal, we carried out some preliminary analyses on the chemical composition, physical shape, and particle size distribution of the sample dust. Next, to quantitatively investigate the effect of adding surfactants to the spraying water on the wettability of the sample dust, the Standard Sink Test was carried out for four different surfactants and at six different concentrations using the surfactants considered in this study. Results of from the preliminary analysis indicated that the main chemical component consisting of the sample dust is Goethite(FeO(OH)) and that the particles smaller than 10 ${\mu}{\textrm}{m}$ in geometric diameter occupy about 36% of the sample dust in mass. This result implies that the fugitive dust generated from the scrap metal handling area at the Port of Inchon should affect the environment nearby more than we have expected. This is because of relatively large mass percentage of the small metal particles less than 10${\mu}{\textrm}{m}$ in geometric diameter, what we may call respirable particles. As for the results of the Standard Sink Test, higher surfactant concentration tends to result in the higher wettability of the sample dust for the surfactants considered in this study, which in turn ensures the high particle collection efficiency of the droplets generated from the water spraying system. Based upon this preliminary results, studies to develop more sophisticated scaled model for dynamic test in underway and the effort to find the best surfactants as well as the optimum operating conditions are being made at the same time.

  • PDF