• Title/Summary/Keyword: Resonance method

Search Result 2,482, Processing Time 0.045 seconds

Structure-activity relationships on the selective herbicidal activity between rice plant and barnyard grass by the N-phenyl substituents in 2-(4-(6-chloro-2-benzoxazolyloxy)-phenoxy)-N-phenyl propionamide derivatives (2-(4-(6-chloro-2-benzoxazolyloxy) phenoxy)-N-phenyl propionamide 유도체 중 N-phenyl 치환체들에 의한 벼와 피의 선택적 제초활성에 미치는 구조-활성관계)

  • Sung, Nack-Do;Lee, Sang-Ho;Chang, Hae-Sung;Kim, Dae-Whang;Kim, Jin-Suk
    • The Korean Journal of Pesticide Science
    • /
    • v.3 no.3
    • /
    • pp.11-19
    • /
    • 1999
  • A some of synthesized 2-(4-(6-chloro-2-benzoxazolyloxy)phenoxy)-N-phenyl propionamide derivativesa substrates were found to selectivity significantly with both rice plant (Oryza sativa L.) and barnyard grass (Echinochloa crus-galli) for those her- bicidal activities with post emergence in up land. The selectivity of substrates against rice plant better than that of Fenoxaprop-ethyl. The structure activity relationship (SAR) n the selectivity of N-phenyl substituents were analyzed by the Free-Wilson and Hansch method. The SAR approach against barnyard grass is shown that the optimal ($({\pi})_{opt.}=1.60$) hydrophobicity and electron donating effects ($0<{\sigma}$ & 0$(ES)_{opt.}=0.87$) so that the herbicidal activity against rice plant can be decreased. The significance of these results on the selectivity between barnyard grass and rice plant is discussed. And it is assumed that the 2-ethoxy-3-methoxy-4-dimethylamino group substituent ($pI_{50}$=6.60, 1g/ha) is selected as the most highest herbicidal activity against barngard grass in green house.

  • PDF

Comparison of the Neurologic Outcome according to the Method of Proximal Graft Anastomosis at the Aortic Side during Off-pump Coronary Artery Bypass Grafting: The Heartstring Sealing System versus Conventional Manual Anastomosis (무심폐기 관상동맥 우회술에 있어서 이식편의 대동맥부 근위부 문합 방법에 따른 수술 후 신경학적 합병증 발생의 비교: 하트스트링을 이용한 방법 대 고식적인 수기 문합술)

  • Cho, Won-Chul;Kim, Joon-Bum;Kim, Hee-Jung;Kim, Hwan-Wook;Kim, Yun-Seok;Jung, Jae-Seung;Choo, Suk-Jung
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.441-446
    • /
    • 2009
  • Background: Side clamping of ascending aorta during proximal graft anastomosis in coronary bypassing surgery in-creases the risk of direct aortic injury as well as embolization of intimal atheroma. Heartstring proximal sealing system (Guidant Corporation, Santa Clara, Calif), developed to avoid aortic side clamping, may minimize risks of such complications. The aim of the current study is to compare the surgical outcomes of the two proximal anastomosis techniquesi.e., Heartstring system versus aortic side clamping in off pump coronary bypassing' surgery (OPCAB). Material and Method: From January 2003 to August 2008, 499 patients underwent OPCAB. Of them, proximal graft anastomosis was performed using Heartstring system in 182 patients (Group I) and conventional manual anastomosis in 317 patients (Group II). The two groups were compared for postoperative major complications and mortality. Result: Two groups showed similar characteristics in terms of preoperative demographic data, left ventricular ejection fraction, renal function and history of diabetes, hypertension and smoking. Although there was no inter-group difference in the history of cerebral ischemia (p=0.48), preoperative brain magnetic resonance angiography revealed greater incidence of severe carotid artery stenosis (>75% of lumen) in the Group I than in the. Group II (44.5% in the Group I and 30.0% in the Group II, p=0.003). There were no inter-group differences in postoperative mortality (p=0.40) and complications (p=0.47) including neurologic events (3 in the Group land 2 in the Group II, p=0.258). Whereas neurologic events all comprised transient ischemic attacks in the Group I, they comprised multiple embolic strokes in the Group II. One patient in the Group II experienced aortic dissection during proximal anastomosis which resulted in ascending aortic replacement. Conclusion: Although proximal anastomosis using Heartstring system did not show statistically significant benefit over aortic side clamping, the. absence of embolic stroke maybe a definite benefit which may be better defined through further studies over a larger cohort.

Detection Characteristics of Gamma-Irradiated Korean Medicinal Herbs by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석에 의한 감마선 조사 한약재의 검지 특성)

  • Yang, Hee-Sun;Park, Yong-Dae;Jin, Chang-Hyun;Choi, Dae-Seong;Chung, Hyung-Wook;Byun, Myung-Woo;Jeong, Il-Yun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1529-1533
    • /
    • 2008
  • The detection characteristics of gamma-irradiated ($0{\sim}10.0\;kGy$) medicinal herbs (Platycodon grandiflorum, Acanthopanax chiisanensis) were investigated by photostimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of the PSL, a first screening method in comparison with the TL, showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples, while the non-irradiated samples yielded photon counts less than 700 counts/60 s (negative). The TL was also applied for the detection method of irradiated medicinal herbs and showed that the non-irradiated sample revealed a glow curve with a low intensity, while the irradiated samples showed a higher intensity. These results were normalized by re-irradiating the mineral grains with a irradiation dose of 1.0 kGy, and a second glow curve was recorded. The ratio of the intensity of the first glow curve ($TL_1$) to that after the normalization dose ($TL_2$) was determined and compared with the recommended threshold values. TL ratio ($TL_1/TL_2$) was below 0.007 for the non-irradiated sample and higher than 0.1 for all irradiated samples (above 1.0 kGy). ESR spectroscopy revealed specific signals (6.065 mT) derived from free radicals in cellulose containing irradiated medicinal herbs. The P. grandiflorum showed clearer signals than A. chiisanensis. From the results of our studies, the PSL, TL, and ESR determinations were found to be suitable for the detection of irradiated medicinal herbs such as P. grandiflorum and A. chiisanensis.

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

Detection Characteristics of Gamma-Irradiated Seeds by using PSL, TL, ESR and GC/MS (PSL, TL, ESR 및 GC/MS 분석을 통한 감마선 조사된 유지종실류의 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Kwak, Ji-Young;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Kim, Jae-I;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.2
    • /
    • pp.130-137
    • /
    • 2013
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL), electron spin resonance (ESR) and gas chromatography/mass spectrometry (GC/MS) methods for 5 seeds which are not allowed to be irradiated in Korea. All 5 seeds including evening primrose seed, safflower seed, rape seed, sunflower seed and flax seed were analyzed. Samples were irradiated at 1~10 kGy using a $^{60}Co$ gamma-ray irradiator. In PSL study, the photon counts of all the unirradiated samples showed negative (lower than 700). The photon counts of irradiated (1, 5, 10 kGy) samples showed positive (higher than 5,000). In TL analysis, results showed that it is possible to apply TL method to all foods containing minerals. In ESR measurements, the ESR signal (single-line) intensity of irradiated foods was higher than non-irradiated foods. The hydrocarbons 1,7-hexadecadiene ($C_{16:2}$) and 8-heptadecene ($C_{17:1}$) from oleic acid were detected only in the irradiated samples before and after the treatment at doses ${\geq}$ 1 kGy, but they were not detected in non-irradiated samples before and after treatment. These two hydrocarbons could be used as markers to identify irradiated safflower seed, rape seed, Sunflower seed and flax seed. And then, the hydrocarbons 1,7,10-hexadecatriene ($C_{16:3}$) and 6,9-heptadecadiene ($C_{17:2}$) from linoleic acid were detected in the evening primrose seed, safflower seed and sunflower seed. According to the results, PSL, TL and GC/MS methods were successfully applied to detect the irradiated foods. It is concluded that PSL, TL and GC/MS methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Development of JPEG2000 Viewer for Mobile Image System (이동형 의료영상 장치를 위한 JPEG2000 영상 뷰어 개발)

  • 김새롬;정해조;강원석;이재훈;이상호;신성범;유선국;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.124-130
    • /
    • 2003
  • Currently, as a consequence of PACS (Picture Archiving Communication System) implementation many hospitals are replacing conventional film-type interpretations of diagnostic medical images with new digital-format interpretations that can also be saved, and retrieve However, the big limitation in PACS is considered to be the lack of mobility. The purpose of this study is to determine the optimal communication packet size. This was done by considering the terms occurred in the wireless communication. After encoding medical image using JPGE2000 image compression method, This method embodied auto-error correction technique preventing the loss of packets occurred during wireless communication. A PC class server, with capabilities to load, collect data, save images, and connect with other network, was installed. Image data were compressed using JPEG2000 algorithm which supports the capability of high energy density and compression ratio, to communicate through a wireless network. Image data were also transmitted in block units coeded by JPEG2000 to prevent the loss of the packets in a wireless network. When JPGE2000 image data were decoded in a PUA (Personal Digital Assistant), it was instantaneous for a MR (Magnetic Resonance) head image of 256${\times}$256 pixels, while it took approximately 5 seconds to decode a CR (Computed Radiography) chest image of 800${\times}$790 pixels. In the transmission of the image data using a CDMA 1X module (Code-Division Multiple Access 1st Generation), 256 byte/sec was considered a stable transmission rate, but packets were lost in the intervals at the transmission rate of 1Kbyte/sec. However, even with a transmission rate above 1 Kbyte/sec, packets were not lost in wireless LAN. Current PACS are not compatible with wireless networks. because it does not have an interface between wired and wireless. Thus, the mobile JPEG2000 image viewing system was developed in order to complement mobility-a limitation in PACS. Moreover, the weak-connections of the wireless network was enhanced by re-transmitting image data within a limitations The results of this study are expected to play an interface role between the current wired-networks PACS and the mobile devices.

  • PDF

Studies on the Applications of PSL, TL and ESR Methods for the Detection of Dried Fruits and Mushrooms (PSL, TL 및 ESR 분석에 의한 건조과일류 및 버섯류에 대한 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Hwang, Cho-Rong;Kim, Jae-I;Lee, Kang-Bong;Jo, Tae-Yong;Eom, Mi-Ok;Park, Sue-Nie;Seong, Rack Seon;Jang, Young-Mi;Lee, Jae-Hwang;Park, Yong-Chjun;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods for various foods. The analysed samples consist of 11 items including dried fruits (6 items) and mushrooms (5 items). To compare between non-irradiated and irradiated food, all samples were irradiated with $^{60}Co$ gamma-ray source. In PSL study, the photon counts of all the unirradiated sample were identified negative (lower than 700). The photon counts irradiated (1, 5, 10 kGy) dried date-palm, dried jujube and mushrooms (Auricularia auricula, Phellinus linteus and Sarcodon aspratus) showed positive (higher than 5,000) and the results for the other samples were negative or intermediate (>700 and >5,000). In TL analysis most of items can be applicable to detect irradiated foods because of showing TL ratio above 0.1. The glow curves by TL method were estimated in the range of $150{\sim}250^{\circ}C$ in irradiated samples. In ESR measurements, the intensity of ESR signal (single-line) increased as the dose of irradiation increased. In particular, the specific ESR signals of irradiation-induced radical were detected in dried papaya, dried date-palm, dried banana, dried pineapple and S. aspratus. According to the results, PSL, TL and ESR methods were successfully applied to detect the irradiated foods. It is concluded that PSL, TL and ESR methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.

MRI study of temporomandibular joint disorder in orthodontic patients (교정환자에서 MRI를 이용한 측두하악관절 장애의 연구)

  • Kim, Tae-Woo;Byun, Eun-Sun;Baek, Seung-Hak;Chang, Young-Il;Nahm, Dong-Seok;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.235-243
    • /
    • 2000
  • Magnetic resonance imaging(MRI) of the temporomandibular joint(TMJ) is very useful method to diagnose internal derangement of the TMJ because of its high specificity foy identification of condyle-disc relationships. The purpose of this study was to evaluate the existence, incidence and severity o』 internal derangement o』 the TMJ by the MRI of Patients who are suspected to have TMJ disorder. MRI sample was composed of 50 subjects(10 males, 40 females) and the mean age was 22.9 years. 43 subjects of the sample were found to have positive findings. $56\%$ of the subjects with positive findings had ADD(anterior disc displacement) without reduction, and $65\%$ had internal derangement of bilateral joints. Distributions in the types of malocclusion in patients with positive findings, the Angle's classification had shown : the largest $41.9\%$ for Cl II ($39.6\%$ for Cl II div 1 and $2.3\%$ for Cl II div 2), $37.2\%$ for Cl I, $18.6\%$ for Cl III, and $2.3\%$ for the unidentified. $8.6\%$ of the subjects with positive findings had facial asymmetry and $55.8\%$ had openbite. We can conclude that the percentage of Cl II is the highest in patients with internal derangement of the TMJ. Openbite or facial asymmetry is considered to be uncompensated or compensated deformity which results from facial skeleton remodeling in the process of degenerative joint disease(DJD) due to TMJ degeneration. Therefore it is recommended to screen the patients with facial asymmetry or openbite by MRI before the beginning of orthodontic treatment. Differential diagnosis is essential because the tendency of relapse is high after the orthodontic treatment and continuous observation of TMJ is needed in patients with TMJ disorder.

  • PDF

Differences in Ability to Predict the Success of Motor Action According to Dance Expertise - Focusing on Pirouette En Dehors (무용 숙련성에 따른 동작결과예측 능력의 차이: 삐루엣 앙 디올 동작을 중심으로)

  • Han, Siwan;Ryu, Je-Kwang;Yi, Woojong;Yang, Jonghyun
    • Korean Journal of Cognitive Science
    • /
    • v.29 no.2
    • /
    • pp.121-135
    • /
    • 2018
  • Dancers' motions are perceived by observers through visual processes with visual information forming the basis for the observers' appreciation and evaluation of the dancers' motions. There have been many discussions as to whether or not observers' personal athletic capabilities form an essential basis for accurate assessment of the motions of others but, so far, no valid conclusions have been reached. The purpose of this study is to investigate how the ability to predict motions of others varies depending on the athletic expertise of the observers. Participants of this research were ballet dancers of varying athletic expertise. Twenty seven participants were divided into three groups with nine in each: beginners, intermediate experts and experts. The participants watched the same dance video and then evaluated whether the motion would be successful or not. The movement related visual information required to evaluate the success of the motion was systematically adjusted by controlling the length of the video. Using the temporal occlusion method, this study measured the response accuracy of the participants by category of expertise. Under the circumstance with insufficient visual information to utilize, the experts showed higher rates of correct response than the intermediate experts and the beginners. The beginners showed higher rates of wrong response than the experts and the intermediate experts. These results showed that the ability to predict success or failure of a dance motion varied depending on motion expertise of the observers, although they had similar level of expertise in perception. Participants considered to have high athletic expertise showed high prediction ability on the result of the motion. In addition, high expertise in perception reduced the likelihood that participants would make hasty responses under the circumstance with insufficient information and helped to reduce wrong response rate. In conclusion, this study showed that motor expertise and perceptual expertise contribute to prediction accuracy of observed motions.