• 제목/요약/키워드: Resonance condition

검색결과 625건 처리시간 0.024초

CORRELATION ASSESSMENT BETWEEN RESONANCE FREQUENCY ANALYSIS AND RADIOGRAPHIC METHOD ACCORDING TO PERI-IMPLANT BONE CHANGE

  • Lee Mi-Ran;Cho Lee-Ra;Yi Yang-Jin;Choi Hang-Moon;Park Chan-Jin
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.736-744
    • /
    • 2005
  • Statement of problem. Initial stability of implant is an important factor for predicting osseointegration. It requires a rapid, non-invasive, user-friendly technique to frequently assess the implant stability and the degree of osseointegration. Purpose. The aim of this study was to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for peri-implant bone change under in vitro conditions. Material and Method. Twenty implants of 3.75 mm in diameter(Neoplant, Neobiotech, Korea) were used. To simulate peri-implant bone change, 2 mm-deep $45^{\circ}$ range horizontal defect and 2 mm-deep $90^{\circ}$ range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of implants and direct digital image was obtained. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. Results. Within a limitation of this study, ISQ value of resonance frequency analysis was changed according to peri-implant bone change (p<0.05) and gray value of radiographic method was changed according to peri-implant bone change (p<0.05). There was no correlation between the ISQ value and the gray value for peri-implant bone change (p>0.05). But, in horizontal defect condition, relatively positive correlation were between ISQ and gray values(r=0.663). Conclusion. This results provided a possibility that peri-implant bone change may be evaluated by both RFA and radiographic method.

Xanthogranulomatous Pancreatitis Mimicking a Pancreatic Cancer on CT and MRI: a Case Report and Literature Review

  • Park, Jong Min;Cho, Seung Hyun;Bae, Han-Ik;Seo, An Na;Kim, Hye Jung;Lee, So Mi;Yi, Jae Hyuck;Lim, Jae-Kwang;Cho, Chang Min
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권3호
    • /
    • pp.185-190
    • /
    • 2016
  • Xanthogranulomatous inflammation is a rare benign condition involving various organs. However, its pancreas involvement is very rare. To the best of our knowledge, only 17 cases have been described in the literature. Interestingly, all reported 17 cases due to various causes underwent surgical resection. Here, we present a case of xanthogranulomatous pancreatitis in a 63-year-old man. He presented with epigastric pain and solid mass mimicking ductal adenocarcinoma in the body and tail of pancreas on magnetic resonance imaging. The patient was diagnosed as xanthogranulomatous pancreatitis via endoscopic ultrasound-guided fine needle aspiration. After that, he was followed up and monitored without any surgical treatment. Here, we show imaging findings and serial image changes of xanthogranulomatous pancreatitis for this case.

Gd3Ga5O12 기판위에 성장된 Y3Fe5O12 박막의 열처리 조건에 따른 강자성 공명 특성 연구 (Effect of the Annealing Conditions on the Ferromagnetic Resonance of YIG Thin Film Prepared on GGG Substrate)

  • 이예림;;박승영;정종율
    • 한국재료학회지
    • /
    • 제25권12호
    • /
    • pp.703-707
    • /
    • 2015
  • In this study, we investigated the effect of annealing conditions on the ferromagnetic resonance(FMR) of yttrium iron garnet ($Y_3Fe_5O_{12}$, YIG) thin film prepared on gadolinium gallium garnet ($Gd_3Ga_5O_{12}$, GGG) substrate. The YIG thin films were grown by rf magnetron sputtering at room temperature and were annealed at various temperatures from 700 to $1000^{\circ}C$. FMR characteristics of the YIG thin films were investigated with a coplanar waveguide FMR measurement system in a frequency range from 5 to 20 GHz. X-ray diffraction(XRD) and X-ray photoelectron spectroscopy(XPS) were used to characterize the phase formation, crystal structure and composition of the YIG thin films. Field dependent magnetization curves at room temperature were obtained by using a vibrating sample magnetometer(VSM). The FMR measurements revealed that the resonance magnetic field was highly dependent on the annealing condition: the lowest FMR linewidth can be observed for the $800^{\circ}C$ annealed sample, which agrees with the VSM results. We also found that the Fe and O composition changes during the annealing process play important roles in the observed magnetic properties.

콘크리트의 탄성계수 및 감쇠비 결정에 대한 충격공진시험 적용 (Application of Impact Resonance Test to the Determination of Elastic Modulus and Damping Ratio of Concrete)

  • 정범석;이재환;권기철
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.625-632
    • /
    • 2010
  • 콘크리트의 탄성계수 결정을 위해 다양한 시험기법이 사용되고 있다. 충격공진시험(IR: impact resonance test)은 비파괴시험으로서 간편한 시험장치와 단순한 시험방법이며 반복성이 뛰어나다. 또한 충격공진시험은 탄성계수 뿐만 아니라 감쇠비 결정이 가능하다. 이 연구에서는 콘트리트 시편에 대한 충격공진시험의 다양한 영향요소(시편거치 방법, 충격하중원의 특성, 신호획득 속도 등)를 평가하고 최적의 시험조건을 제시하였다. 이 연구에서 적용한 모든 시험조건 범위에서 충격공진시험에서 측정된 결과의 변동량은 공진주파수 결정에 있어서 ${\pm}0.3%$, 감쇠비 결정에 있어서 ${\pm}10.0%$로 나타났다. 충격공진시험에서 결정된 탄성계수와 정적시험에서 결정된 탄성계수를 변형률 크기를 고려하여 비교하면 비교적 서로 잘 일치함을 확인하였다.

정밀가공용 고속 자동선반 베드의 정하중 및 공진주파수 해석 (Analysis on Static Load and Resonance Frequency of Bed in High-speed Automatic Lathe for Precision Machining)

  • 하주환;이윤철;주강우;조은정;이영식;이재권;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제16권2호
    • /
    • pp.32-38
    • /
    • 2017
  • This paper is about the analysis on the vibration characteristic of tooling units on the precision bed in high-speed automatic lathe for precision machining. An automatic lathe operating at about 25,000 RPM is a critical factor in the self-weight stress and deformation of the bed. Especially, the resonance frequency should be grasped in advance to prevent abnormal vibration that may occur during processing. If the wrong bed is used, the resonant frequency can have a fatal influence on the precision machining and increase the defective rate of precision machined parts such as semiconductor parts. In this paper, vibration characteristics were evaluated through static load and resonance frequency analysis of automatic lathe bed. As a result, the maximum stress was 0.14MPa, the maximum deformation amount was $17.9{\mu}m$, and the natural frequency was 364.72Hz. The resonance frequency was calculated as 718Hz, and the stability was confirmed by being in the range of 400Hz or more, which is the processing condition.

  • PDF

선삭 및 호빙 가공용 자동선반 베드의 정하중 및 공진주파수 해석 (Analysis on Static Load and Resonance Frequency of Bed in Turning and Hobbing Automatic Lathe for Precision Machining)

  • 하주환;이윤철;조은정;이영식;이재권;김광선
    • 반도체디스플레이기술학회지
    • /
    • 제17권1호
    • /
    • pp.66-70
    • /
    • 2018
  • This paper is about the analysis on the vibration characteristic of tooling units on the precision bed in turning and hobbing automatic lathe for precision machining. An automatic lathe operating at about 12,000 RPM is a critical factor in the self-weight stress and deformation of the bed. Especially, the resonance frequency should be grasped in advance to prevent abnormal vibration that may occur during processing. If the wrong bed is used, the resonant frequency can have a fatal influence on the precision machining and increase the defective rate of precision machined parts such as semiconductor parts. In this paper, vibration characteristics were evaluated through static load and resonance frequency analysis of automatic lathe bed. As a result, the maximum stress was 14.52 MPa, the maximum deformation amount was $12.15{\mu}m$, and the natural frequency was 189.43 Hz. The resonance frequency was calculated as 500 Hz, and the stability was confirmed by being in the range of 200 Hz or more, which is the processing condition.

Response of estuary flow and sediment transport according to different estuarine dam locations and freshwater discharge intervals

  • Steven Figueroa;Minwoo Son
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.519-519
    • /
    • 2023
  • Estuarine dams are a recent and global phenomenon. While estuarine dams can provide the benefit of improved freshwater resources, they can also alter estuarine processes. Due to the wide range of estuarine types and estuarine dam configurations, the effect of estuarine dams on estuaries is not well understood in general. To develop a systematic understanding of the effect of estuarine dam location and freshwater discharge interval on a range of estuarine types (strongly stratified, partially mixed, periodically stratified, and well-mixed), this study used a coupled hydrodynamic-sediment dynamic numerical model (COAWST) and compared flow, sediment transport, and morphological conditions in the pre- and post-dam estuaries. For each estuarine type, scenarios with dam locations at 20, 55 and 90 km from the mouth and discharge intervals of a discharge every 0.5, 3, and 7 days were investigated. The results were analyzed in terms of change in tide, river discharge, estuarine classification, and sediment flux mechanism. The estuarine dam location primarily affected the tide-dominated estuaries, and the resonance length was an important length scale affecting the tidal currents and Stokes return flow. When the location was less than the resonance length, the tidal currents and Stokes return flow were most reduced due to the loss of tidal prism, the dead-end channel, and the shift from mixed to standing tides. The discharge interval primarily affected the river-dominated estuaries, and the tidal cycle period was an important time scale. When the interval was greater than the tidal cycle period, notable seaward discharge pulses and freshwater fronts occurred. Dams located near the mouth with large discharge interval differed the most from their pre-dam condition based on the estuarine classification. Greater discharge intervals, associated with large discharge magnitudes, resulted in scour and seaward sediment flux in the river-dominated estuaries, and the dam located near the resonance length resulted in the greatest landward tidal pumping sediment flux and deposition in the tide-dominated estuaries.

  • PDF

척추 경막외 지방종증 -증례보고- (Spinal Epidural Lipomatosis -A case report-)

  • 김세영
    • The Korean Journal of Pain
    • /
    • 제22권3호
    • /
    • pp.249-252
    • /
    • 2009
  • Spinal epidural lipomatosis (SEL) is a rare condition of pathological overgrowth of fat tissue in the vertebral canal. SEL leads to back pain, radiculopathy or paraparesis. Glucocorticoids seem to play a major role in the development of SEL. SEL is best diagnosed by magnetic resonance imaging. The treatment of SEL is directed at reducing the body weight and decreasing the excess glucocorticoid. In severe cases, decompressive laminectomy with removal of the excess epidural fat might become necessary to alleviate the neurological symptoms caused by spinal cord compression.

Thoracic Actinomycosis Causing Spinal Cord Compression

  • Kim, In-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권4호
    • /
    • pp.289-292
    • /
    • 2006
  • Thoracic spinal actinomycosis causing epidural abscess and significant spinal cord compression is very rare. A case is presented of a 56-year-old woman with rapid progressive upper back pain and weakness in both legs without evidence of systemic infection. Magnetic resonance imaging revealed a thoracic epidural enhancing lesion at the T1-T5 level. After decompression by laminectomy, precise diagnosis was accomplished using specific histopathological studies of the surgical specimens. A histopathologic findings showing typical Actinomyces sulfur granules surrounded by acute inflammatory cells. The clinical radiological findings of spinal actinomycosis closely resemble metastatic tumors and other infectious processes. Delay in diagnosis and treatment can significantly worsen the condition of patient.

전력계통에 있어서 FC - TCR 장치의 고조파 제어에 관한 연구 (A Study on Harmonic Elimination of FC-TCR in Power System)

  • 김준현;김영만;이승주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.127-130
    • /
    • 1988
  • This paper describes digital simulation of harmonic elimination in the FC-TCR. (Fixed Capacitor and Thyristor Controlled Reactor) A model at harmonic frequency is developed for a STATIC VAR compansator. The model is shown to be useful in predicting resonance condition. A new variable filter is used for synthesized harmonic elimination.

  • PDF