• 제목/요약/키워드: Resonance characteristics

검색결과 1,863건 처리시간 0.028초

공진을 고려한 발전소 여자기 지지부의 동특성 개선 (Dynamic Characteristic Improvement for Journal Bearing Support of Power Plant Exciter considering Resonance)

  • 양경현;조철환;배춘희;원종범;김성휘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.156-160
    • /
    • 2000
  • When the structure supporting the rotor as well as the rotor itself is in the resonant range, it cause the vibration problem. Although the static characteristics of structures was considered during the design process, we must consider the resonance problem between the excitation(the main revolution frequency of the rotor) between the dynamic characteristics of its structures. This paper presents we improved the dynamic characteristic of a bearing support system to remove a resonance problem so that stabilized the turbine-generator system.

  • PDF

Characteristics of MnxSi1-xTe Compound Studied by Electron Magnetic Resonance and Other Experiments

  • Na, Sung-Ho;Kim, Heung-Chul;Park, Jung-Woo;Kim, Jang-Whan
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.23-29
    • /
    • 2008
  • The magnetic and other physical characteristics of $Mn_xSi_{1-x}Te$ have been investigated by electron magnetic resonance (EMR), X-ray diffraction (XRD) and other experiments. $Mn_xSi_{1-x}Te$ is found to have corundum structure for manganese contents up to 10% and also to be ferromagnetic for temperatures below 80 K. While ferromagnetic resonance signal coexists with the usual paramagnetic resonance signal, invariance of the g-factor inferred from the electron paramagnetic resonance signals throughout all temperature ranges clearly confirms that the manganese ions are in the electronic 3d5 state. The temperature dependence of EMR line-width is the same as other diluted magnetic semiconductors. From the EMR signals relaxation times $T_2$ and $T_1$ of $Mn_xSi_{1-x}Te$ compounds are estimated to be about $4.4{\times}10^{-10}s$ and $9.3{\times}10^{-8}s$ respectively and are found to vary slightly with temperature or composition change. Exchange narrowing of the EMR line-width becomes dominant for the sample in which the substitution ratio, x = 30%. For one sample, in which x = 0.5%, spin glass-like behavior is indicated by EMR signals for temperatures lower than 60 K. This behavior may authentic for samples within a certain range of x.

지그재그 다이폴 안테나의 집적화와 공진 특성 개선에 관한 연구 (A Study on the Integration of Zigzag Dipole Antennas and Improvement of Its Resonance Characteristics)

  • 전후동;이영순;박의준
    • 대한전자공학회논문지TC
    • /
    • 제43권4호
    • /
    • pp.44-51
    • /
    • 2006
  • 본 논문에서는 우선 지그재그 와이어 다이폴 안테나 공진 특성을 모멘트법을 사용하여 분석함으로써, 직선형 와이어 안테나의 공간 점유 길이를 단축시킬 수 있음을 보였다. 이 단축 효과를 고려하여, 간소화된 마이크로스트립 급전부를 갖는 집적화된 지그재그 다이폴 안테나를 설계하였다. 집적화시 안테나 라인 폭의 급격한 구부림 각도에 의해 불연속이 존재하므로 chamfer를 적용함으로써 보상시키고, 유전체 기판의 영향을 고려하여 기판 양면에 기생소자 역할을 하는 지그재그 라인을 부가함으로써 공진특성을 개선시켰다. UHF와 ISM 대역에서 설계된 결과들의 타당성을 실험을 통해 입증하였다.

KTX 운행에 따른 가선설비 유리애자의 진동특성과 파손 가능성 검증 (The Verification of Breakage Possibility and Vibration Properties of Glass Insulators by the High-speed Railway Service)

  • 김영석;송길목;정진수;전용주
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.566-572
    • /
    • 2009
  • This paper has studied breakage possibility of glass insulators by resonance and accelerated deterioration through the comparison of the natural vibration and on site vibration. The natural frequencies of the strut tube glass insulator was measured within a range of less than 1kHz. In the on site vibration, the largest frequency that was imposed on strut tube glass insulators was 80Hz with 1.13g of vertical vibration in the viaduct section, the largest vertical vibration (0.38g) was detected at 103Hz in the open route section. When site vibration and natural vibration of strut tube glass insulators were compared in terms of characteristics, the resonance frequency was not the same. In both the viaduct and open route sections, it seems that the impact by vertical vibration in strut tube glass insulators is large. It's very unlikely that glass insulators were damaged by fatigue accumulation of vibration since the possibility of damage by resonance was very low in consideration of the characteristics of natural vibration and site vibration of glass insulators. In addition, no damage was detected in the accelerated deterioration test.

복합재 쿼드콥터의 진동 특성 분석과 공진 회피에 대한 연구 (Research of Vibration Analysis and Resonance Avoidance Design of Composite Quadcopter)

  • 김상률;김위대
    • Composites Research
    • /
    • 제33권3호
    • /
    • pp.133-139
    • /
    • 2020
  • 본 연구에서는 복합재료가 적용된 쿼드콥터의 진동 특성을 분석하고, 공진에 대해 회피 설계 및 해석을 수행하였다. 로터-암의 파이프가 복합재료로 구성된 상용 쿼드콥터의 플랫폼을 모사하고 상용 해석 프로그램을 이용하여 진동 특성 분석을 하였다. 실제 적층 배열을 해석에 적용하고, 참고 문헌과의 비교를 통해 신뢰성을 판단하였다. 그리고 모터의 가동범위 내에 특정 모드의 고유 진동수가 포함되는 것을 확인하였다. 기존 모델에서 적층 배열, 로터-암의 길이, 두께의 총 3가지의 변수를 선정해 공진 회피 설계를 수행하였다. 공진 회피 설계의 3가지 변수에서 각 해석의 결과를 비교한 후, 공진 회피 설계의 효율성 측면에서 방향을 제시하였다.

음향 공명 현상을 고려한 세라믹 메탈핼라이드의 특성 분석과 PSpice 시뮬레이션을 통한 인버터 설계 (The Property Analysis of Ceramic Metal-Halide Lamp Considering Acoustic Resonance Phenomenon and Design of Inverter by the PSpice Simulation)

  • 장혁진;김남군;양종경;이종찬;박대희
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1989-1994
    • /
    • 2009
  • This study purposes are improvement of system (lamp & ballast) efficacy with and optical characteristics through the developed ceramic arc tube. The designed electronic ballast is substituted for conventional magnetic ballast. These electric signal and optical, thermal characteristics through the improving efficacy of lighting system compared with conventional magnetic ballast. properties of lamp by driving method is researching in ballast. Particularly, electronic ballasts, which improved against weakness of Magnetic Ballast, are researching and applying to control of ceramic metal-halide lamp. but One major limitation is the acoustic resonance problem in CMH lamps at high-frequency operation. In order to avoid acoustic resonance, driving frequency decided 21[kHz]. Before discharge in this paper. The PSpice simulation result obtained sufficient voltage gain and the ignition voltage obtained over 3[kV] at 75[kHz]. After discharge, driving voltage obtained approximately 90[Vrms] at 21[kHz].

TO-can 패키지 레이저 다이오드 모듈의 주파수 특성 개선 (RF Characteristics of TO-can Packaged FP-LD Optical Transceiver Module)

  • 이동수
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.8-12
    • /
    • 2003
  • TO-can 레이저 다이오드를 사용한 광송수신기 모듈의 주파수 대역의 특성을 관찰하였다. 레이저 다이오드의 등가회로를 추출하기 위한 R-L-C변수는 임피던스 분석기를 이용하였다. 칩콘덴서를 사용하여 패키지내의 도선에 의한 인덕턴스 성분과의 임피던스 정합을 시도하였으나 저주파수 대역에서 공진으로 인한 경사가 발견되었다. 표면실장 형으로 소자를 구성하여 사용함으로써 공진주파수를 이동시켜 원하는 주파수 대역에서 공진 경사를 제거할 수 있었다.

플라즈모닉스 현상을 이용한 전반사 기반 다층 유전체 박막 센서의 특성 분석 (Characteristics Analysis of Total Internal Reflection-based Dielectric Multi-layer Sensor Using Plasmonics Phenomena)

  • 김홍승;이태경;김두근;정유라;오금윤;이병현;기현철;최영완
    • 한국전기전자재료학회논문지
    • /
    • 제25권7호
    • /
    • pp.516-520
    • /
    • 2012
  • In this paper, we have theoretically analyzed and designed a dielectric multi-layer sensor with a SPR (surface plasmon resonance) using analytical calculation and FDTD (finite difference time-domain) methods. The proposed structure is composed of periodic layer and thin metal film. It has many advantages. One of that is a high sensitivity of the SPR. Another is a high Q-factor of the characteristics in the PhC (photonic crystals) micro-cavity structure. The incident light has double resonance characteristics, because the filtered light by PhC structure, dielectric multi-layer, is met the thin metal film for SPR effect. We have also observed the change of resonance characteristics according to the variation of effective index on the metal film.

자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가 (Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원;한지현;이시내;김민지;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권1호
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

Natural Frequency Analysis of Spring-Manipulator System for Force Generation Utilizing Mechanical Resonance

  • Kobayashi, Jun;Ohkawa, Fujio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1651-1656
    • /
    • 2005
  • This paper describes a natural frequency analysis conducted to find out a suitable working area for a spring-manipulator system generating a large vibrating force with mechanical resonance. Large force generation is one of the functions that we hope for a robot. For example, a weeding robot is required to generate a large force, because some weeds have roots spreading deeply and tightly. The spring-manipulator system has a spring element as an end-effector, so it can be in a state of resonance with the elasticity of the spring element and the inertial characteristics of the manipulator. A force generation method utilizing the mechanical resonance has potential to produce a large force that cannot be realized by a static method. A method for calculating a natural frequency of a spring-manipulator system with the generalized inertia tensor is proposed. Then the suitable working area for the spring-manipulator system is identified based on a natural frequency analysis. If a spring-manipulator system operates in the suitable working area, it can sustain mechanical resonance and generate a large vibrating force. Moreover, it is shown that adding a mass at the tip of the manipulator expands the suitable working area.

  • PDF