• 제목/요약/키워드: Resonance Type

검색결과 1,085건 처리시간 0.033초

포커성 방법을 이용한 이차원 음향 영상에 관한 연구 (A Study of Two-Dimensional Acoustic Image using Focusing Method)

  • 김형균
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1984년도 추계학술발표회 논문집
    • /
    • pp.78-82
    • /
    • 1984
  • The purposed of this paper is to realize two dimensional acoustic image using focusing method. In the experiment, it consists of phase delay part, 14 analog multiplexers, multi-amplifiers, A/D converter, DMA interfacing parts, two linear arrays(resonance frequency 25 KHz, radius 0.75 Cm diac type). Finally in this experimental result, both electrical deflection and dynamic focusing are realized and gets two dimensional acoustic image using focusing method.

  • PDF

3상 VR 형 스텝 모터의 미세스텝 구동 특성에 관한 연구 (Microstepping drive of 3 phase multi-stack VR type step motor)

  • 이성주;원종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.21-23
    • /
    • 1988
  • Microstepping drive of 3 phase VR step motor with 2 phase exciting scheme is proposed. Considering the presence of harmonic components of inductance, the current reference is calculated. The experimental results show high accuracy of divided step position and resonance or instability in operating range.

  • PDF

3.0-Tesla 자기공명 영상장치용 TX/RX C-spine RF Coil의 개발

  • 류연철;류승학;최보영;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.143-143
    • /
    • 2001
  • 목적: 현재 3.0T MRI system은 세계적으로 개발이 진행되고 있는 가운데, 3.0T에서 사용할 수 있는 RF coil의 개발이 시급한 상황이다. 1.0T 및 1.5T MRI 와는 달리 3.0T에서 사용할 수 있는 Body coil 및 그에 따른 High power RF amplifier 제작에 많은 제약이 있다. 작은 용량의 RF amplifier를 이용하여 신체의 부분을 촬영 하고자 한다면, Tx/Rx 가능한 coil을 이용하면 가능할 것이다. 이러한 이유로 본 연구에서는 Tx/Rx 가능한 Quadrature type C-spine RF coil을 설계, 제작하여 3.0T 고자장 자기공명 영상장치에서의 임상진단 활용범위를 확대하였다.

  • PDF

충격식 감쇠기의 감쇠특성에 관한 연구 (Damping Characteristics of Impact Damper)

  • 김원철;전순기;양보석;문덕호
    • 소음진동
    • /
    • 제3권1호
    • /
    • pp.29-37
    • /
    • 1993
  • This study is concerned about the impact type damper for effectively restraining the high vibration amplitude in the resonance regions. The theoretical analysis is based on the assumption that the impacts occur twice per cycle at an equal time interval. Simple but reasonable approximations have been derived for the optimum collision clearance and maximum amplitude ratio. Using the impact dampers which is rigidly attached to the primary vibration system, we have experimented for mass ratios and restitution coefficients. The experimental results are in good agreement with theoretical results.

  • PDF

압전 비틀림 변환기의 진동특성 해석 (Vibration Characteristics of Piezoelectric Torsional Transducers)

  • 권오수;김진오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1280-1285
    • /
    • 2000
  • The paper deals with a theoretical study on the vibrational characteristics of piezoelectric torsional transducers. The differential equations of piezoelectric torsional motion have been derived in terms of the circumferential displacement and the electric potential. Applying mechanical and electrical boundary conditions has yielded the characteristic equations of natural vibration in several transducer types. Numerical results have clarified the effect of the piezoelectric phenomenon on the mechanical resonance and the effect of the elastic block of a Langevin-type transducer on the natural frequency.

  • PDF

압전 비틀림 변환기의 진동특성 해석 (Vibration Characteristics of Piezoelectric Torsional Transducers)

  • 권오수;김진오
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.955-962
    • /
    • 2000
  • The paper deals with a theoretical study on the vibrational characteristics of piezoelectric torsional transducers. The differential equations of piezoelectric torsional motion have been derived in terms of the circumferential displacement and the electric potential. Applying mechanical and electrical boundary conditions has yielded the characteristic equations of natural vibration in several transducer types. Numerical results have clarified the effect of the piezoelectric phenomenon on the mechanical resonance and the effect of the elastic block of a Langevin-type transducer on the natural frequency.

  • PDF

고균등자장 발생용 초전도 마그네트의 설계 (Design of high homogeneity superconducting magnet)

  • 진홍범;나완수;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.192-194
    • /
    • 1994
  • High homogeneity and stability are required in superconducting magnet for Magnetic Resonance Imaging. In this paper, Magnetic Field theories for the design of high homogeneity magnet are introduced and multi-sections solenoid type coils are optimzed to produce highly homogeneous field.

  • PDF

Magnetism in the Layered Structure Compound (C_18H_37NH_3)_2 MNCL_4

  • Lee, K. W.;Lee, C. H.;C. Rhee;Lee, Cheol-Eui;J. K. Kang;Lee, K.-S.
    • Journal of Magnetics
    • /
    • 제2권4호
    • /
    • pp.126-129
    • /
    • 1997
  • We have studied magnetostructural phase transitions in the perovskite-type layered structure compound (C18H37NH3)2 MnCl4 by means of electron paramagnetic resonance (EPR) and superconducting quantum interference device (SQUID) measurements. Distinct slopes were observed in the linear temperature dependences of the Mn++ EPR linewidth in the low and high temperature phases. Besides, linewidth anomalies at the transition temperatures sensitively reflect the magnetic changes arising from the MnCl6 octahedra.

  • PDF

페니토인 사용에 따른 소뇌 위축 사례 (A case of phenytoin-induced cerebellar atrophy)

  • 김재현
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2016년도 춘계 종합학술대회 논문집
    • /
    • pp.433-434
    • /
    • 2016
  • Cerebellar atrophy was found that a patient was taking oral phenytoin for 3 years. 53 years old female patient with General tonic clonic(GTC) type seizure was prescribed phenytoin. In the process, she developed ataxic gate, dysarthria. Brain magnetic resonance imaging(MRI) finding was revealed differential diagnosis cerebellar atrophy. She was prescribed epileptol instead of phenytoin. But leukopenia, thrombocytopenia occurred. As a result, phenytoin restarted. Development of medical state decreased abuse of anticonvulsants. Considering various convulsive disorders, we must give attention to using anticonvulsants.

  • PDF

HDD용 압전형 마이크로 액츄에이터의 비선형 진동특성 (Nonlinear Vibration Characteristics of Piezoelectric Microactuators in Hard Disk Drive Drives)

  • 정덕영;이승엽;김철순
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.225-231
    • /
    • 2000
  • Nonlinear characteristics of piezoelectric-type micro actuator used for hard disk drives are experimentally analyzed using Hutchinson's Magnum acturator. The nonlinear effects include hysteresis, superharmonic resonance, jump phenomenon, and shifting of natural frequencies. The effects of exciting frequency and input voltage on the nonlinear phenomena are investigated. It is shown that the micro actuator has the typical 3 times superhamonic resonances coupled to both 1st torsional and sway modes of the suspension.

  • PDF