• Title/Summary/Keyword: Resonance Type

Search Result 1,085, Processing Time 0.034 seconds

Analytical Study on Stall Stagnation Boundaries in Axial-Flow Compressor and Duct Systems

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.2
    • /
    • pp.56-74
    • /
    • 2013
  • Stall stagnations in the system of axial-flow compressors and ducts occur in transition from deep surge conditions to decayed or converged stall conditions. The present study is concerned with the boundaries between the deep surges and the stagnation stalls on the basis of analytical results by a code on surge transients analysis and simulation. The fundamental acoustical-geometrical stagnation boundaries were made clear from examinations of the results on a variety of duct configurations coupled with a nine-stage compressor and a single stage fan. The boundary was found to be formed by three parts, i.e., B- and A-boundaries, and an intermediate zone. The B-boundary occurs for the suction-duct having a length of about a quarter of the wave-length of the first resonance in the case of very short and fat plenum-type delivery duct. On the other hand, the A-boundary occurs for the long and narrow duct-type delivery flow-path having a length about a fifth of the wavelength and relatively small sectional area in the case of short and narrow suction ducts. In addition to this, the reduced surge-cycle frequencies with respect to the duct lengths are observed to have respective limiting values at the stagnation boundaries. The reduced frequency for the B-boundary is related with a limiting value of the Greitzer's B parameter. The tendency and the characteristic features of the related flow behaviors in the neighborhood of the boundaries were also made clearer.

A High Voltage Power Supply for X-Ray Tube Using High Frequency (고주파 인버터식 X-선관용 고전압 전원장치)

  • Kim, H.S.;Yoo, D.W.;Cho, J.G.;Back, J.W.;Rim, G.H.;Won, C.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2246-2248
    • /
    • 1997
  • This paper presents a high-frequency inverter type high-voltage power supply for X-ray equipments. The high-voltage generator consist of an inverter unit including the SR(Series Resonance) type PSC(Phase-Shifted Control) PWM circuit adopting IGBT as the switching power device and high-voltage unit including the CW(Cockcroft Walton) circuit. When the X-ray equipment is radiographing at large power for a short time, this generator operates through feedback voltage mode control to obtain a high speed leading edge and low ripple. The operating modes and design consideration of the proposed power supply are given. Issues in the design of high-voltage divider for high voltage measuring. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advantages, e.g., the fast rising time of tube voltage, accuracy and reduced component size etc.

  • PDF

Effect of Surface Flaw Type on Ultrasonic Backscattering Profile (표면결함유형이 초음파 후방산란 프로파일에 미치는 영향)

  • Kwon, Sung-D.;Yoon, Seok-S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.6
    • /
    • pp.658-662
    • /
    • 2001
  • The classification of surface flaw types was performed on the basis of angular dependence of backscattered ultrasound. The copper line adhered on the surface, cower line filled in groove, pure groove and the normal edge were adopted as various surface flaw patterns of glass specimen. A backward longitudinal profile was formed probably by the longitudinal wane scattering at and near 1st critical angle. The wave trains at the peak angles of the backward radiation profiles showed different shapes according to the superposition ratio of scattered and leaky waves. The asymmetry of the backward radiation profile arose due to the scattering effect of flaw. The additive resonance effect of copper line appeared in the left side of the profile. The peak angles of both the longitudinal and radiation profiles were shifted toward small angle by the scattering effect.

  • PDF

Theoretical Curve of Classical Site Attenuation for Forced Resonant Type EMI Dipole Antennas (강제 공진형 EMI 다이폴 안테나에 대한 시험장 감쇠량 이론 곡선)

  • Ju Chang-Hyun;Park Eun-Jung;Kim Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.571-579
    • /
    • 2005
  • This paper presents the classical site attenuation characteristics of a forced resonant electromagnetic interference (EMI) dipole antenna for frequencies below 80 MHz. The coupled integral equations for unknown current distribution are solved by the Galerkin's method of moments with piecewise sinusoidal functions. The results show that the forced resonant type EMI dipole antenna for frequencies below 80 MHz can be used effectively for measuring the classical site attenuation of horizontal polarization. The theoretical site attenuation curves presented can be used as reference curves for evaluating the performance of an open area test site.

Study on Characteristics of Various RF Transmission Line Structures on PES Substrate for Application to Flexible MMIC

  • Yun, Young;Kim, Hong Seung;Jang, Nakwon
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.106-115
    • /
    • 2014
  • In this work, the coplanar waveguide is fabricated on a PES (poly[ether sulfone]) substrate for application to a flexible monolithic microwave integrated circuit, and its RF characteristics were thoroughly investigated. The quality factor of the coplanar waveguide on PES is 40.3 at a resonance frequency of 46.7 GHz. A fishbone-type transmission line (FTTL) structure is also fabricated on the PES substrate, and its RF characteristics are investigated. The wavelength of the FTTL on PES is 5.11 mm at 20 GHz, which is 55% of the conventional coplanar waveguide on PES. Using the FTTL, an impedance transformer is fabricated on PES. The size of the impedance transformer is $0.318mm{\times}0.318mm$, which is 69.2% of the size of the transformer fabricated by the conventional coplanar waveguide on PES. The impedance transformer showed return loss values better than -12.9 dB from 5 GHz to 50 GHz and an insertion loss better than -1.13 dB in the same frequency range.

An Experimental Study on the Sound Absorption Property of a Sintered Clay Material (점토 소결재의 흡음특성에 관한 실험적 연구)

  • Yang, Yoon-Sang;Lee, Dong-Hoon;Seo, Eun-Sung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.365-371
    • /
    • 2013
  • The purpose of this study is to develop a sound absorbing material for indoor which manufactured by a clay and binding material. The seven kind of sound absorbing specimens which sintered through a mold process at high temperature were manufactured for the purpose of testing sound absorption performance. The random and normal sound absorption coefficients were measured for the sintered clay sound absorbing specimens with different particle size, density and mixture ratio. From the experimental results, it was found that its particle size was closely related to the sound absorption performance. It was shown that the sintered clay sound absorbing specimen had the sound absorption properties of a fiber-type or a resonance-type sound absorbing material depending on the particle size.

Optimal Design and Performance Evaluation of PZT-driven Stage Using Min-Max Algorithm (Min-Max 알고리즘을 이용한 피에조 구동형 스테이지의 최적설계 및 성능평가)

  • Choi Kee-Bong;Han Chang Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.9 s.174
    • /
    • pp.130-136
    • /
    • 2005
  • This paper presents an optimal design and the performance evaluation of two-axis nano positioning stage with round notched flexure hinges. A flexure hinge mechanism with round notched flexure hinges is to guide the linear motions of a moving plate in the nano positioning stage. A Min-Max algorithm is applied to the design of the flexure hinge mechanism for nano positioning stage. In the design process, the structure of the flexure hinge mechanism is fixed, then the radius of a round hole and the width of two round holes are chosen as design variables, and finally the do sign variables are calculated by the Min-Max algorithm. The machined flexure hinge mechanism, stack type PZTs for actuation and capacitance type displacement sensors for position measurement are assembled into the nano positioning stage. The experimental results of the manufactured nano positioning stage show the first modal resonance frequency of 197 Hz, the operating range of 40 um, and the resolution of 3 nm.

Possible Development of Modified SLAP Ⅱ and Bankart Lesion After Shoulder Avulsion injury -A Case Report- (전방 급성 견열손상 후 발생한 변형된 SLAP Ⅱ손상과 전방 관절순 파열 -증례 보고 1 례-)

  • Yoo Jae Chul;Kwak Ho-Yoon;Hwang Seung-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.7 no.1
    • /
    • pp.10-13
    • /
    • 2004
  • Superior labrum anterior to posterior (SLAP) lesions of the shoulder has recently been a popular issue to shoulder surgeons. Now we are correlating many shoulder symptoms to this SLAP lesion. A 45 year-old female patient injured her shoulder when her arm sleeve was entrapped in moving automobile door. A forceful pull of the arm in external and abduction position was suspected. She complained continuous shoulder pain with limited range of motion for 2 months. Magnetic resonance image showed possible SLAP lesion but no definite diagnosis were made prior to the operation. Arthroscopic evaluation revealed SLAP type Ⅱ lesion with concomitant avulsion of the superior glenoid cartilage. In addition anterior labrocapsular tear was seen from 7 to 9 o'clock of anterior glenoid. The SLAP lesion and the anterior capsulolabral lesion were repaired properly to the glenoid. We report a case of glenoid-cartilage avulsion type of SLAP Ⅱwith anterior labrocapsular lesion.

Malignant Peripheral Nerve Sheath Tumor of Non-Neurofibromatosis Type I Metastasized to the Cerebrospinal Axis

  • Park, Man-Kyu;Sung, Joo-Kyung;Nam, Kyung-Hun;Kim, Kyoung-Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.190-193
    • /
    • 2013
  • A malignant peripheral nerve sheath tumor (MPNST) is a type of sarcoma that arises from peripheral nerves or cells of the associated nerve sheath. This tumor most commonly metastasizes to the lung and metastases to the spinal cord and brain are very rare. We describe a case of young patient with spinal cord and brain metastases resulting from MPNST. An 18-year-old man presented with a 6-month history of low back pain and radiating pain to his anterior thigh. Magnetic resonance imaging showed a paraspinal mass that extended from the central space of L2 to right psoas muscle through the right L2-3 foraminal space. The patient underwent surgery and the result of the histopathologic study was diagnostic for MPNST. Six months after surgery, follow-up images revealed multiple spinal cord and brain metastases. The patient was managed with chemotherapy, but died several months later. Despite complete surgical excision, the MPNST progressed rapidly and aggressively. Thus, patients with MPNST should be followed carefully to identify local recurrence or metastasis as early as possible.

Development of Boost Type Bidirectional ZCS DC/DC Converter For EV of Transformer Series Construction (변압기 직렬구조의 EV용 승압형 양방향 ZCS DC/DC 컨버터 개발)

  • Choi, Jung-Sik;Park, Byung-Chul;Chung, Dong-Hwa;Song, Sung-Gun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.37-46
    • /
    • 2013
  • This paper proposes the boost type bidirectional zero current switching(ZCS) DC/DC converter of transformer series construction for electric vehicle operation using low voltage battery. This converter can high boost through the double voltage circuit and series construction of output part using two converters. This converter system has the advantages that bidirectional power transfer is excellent, size and making of transformer because of this converter keeps the transformation ratio to 1:1. Proposed DC/DC converter uses the ZCS method to decrease the switching loss. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer and half-bridge capacitor it reduces system size and expense because of not add special reactor. It can confirm to output of high voltage to operate the electric vehicle with low voltage of input and operation of ZCS in all load region through the result of PSIM simulation and experiment.