• Title/Summary/Keyword: Resonance Suppression

Search Result 135, Processing Time 0.035 seconds

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging III (정형 보철용 금속이 자기공명영상에 미치는 영향 III)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.42-47
    • /
    • 2012
  • Followed by a paper on the Pig and Bone orthopedic prosthetic, this experiment using Phantom and Bone MRI imaging I, II of orthopedic prosthetic metal effect combines magnetic resonance imaging on metal signal-to-noise ratio(Signal to noise : SNR) and CNR(Contrast to noise: CNR), fat signal suppression(Fat-suppression) images was compared. Specimen trees to measure the reliability of the experimental reproducibility tests and statistical analysis using the SPSS statistical package was applied program SPSS(IBM SPSS Statistice 19) by * P = 0.000 < significance level $({\alpha})$ = 0.01 as a significant there was a correlation(** P < 0.01). SNR and CNR results did not directly proportional to the Titanium, Stainless, Clip CNR and fat signal suppression of the order of images of blood specimens was found to be close to the image. The impact of orthopedic prosthetic metals on magnetic resonance imaging in the diagnostic value of Titanium is relatively high and are meant more.

A Double Bi-Quad Filter with Wide-Band Resonance Suppression for Servo Systems

  • Luo, Xin;Shen, Anwen;Mao, Renchao
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1409-1420
    • /
    • 2015
  • In this paper, an algorithm using two bi-quad filters to suppress the wide-band resonance for PMSM servo systems is proposed. This algorithm is based on the double bi-quad filters structure, so it is named, "double bi-quad filter." The conventional single bi-quad filter method cannot suppress unexpected mechanical terms, which may lead to oscillations on the load side. A double bi-quad filter structure, which can cancel the effects of compliant coupling and suppress wide-band resonance, is realized by inserting a virtual filter after the motor speed output. In practical implementation, the proposed control structure is composed of two bi-quad filters on both the forward and feedback paths of the speed control loop. Both of them collectively complete the wide-band resonance suppression, and the filter on the feedback path can solve the oscillation on the load side. Meanwhile, with this approach, in certain cases, the servo system can be more robust than with the single bi-quad filter method. A step by step design procedure is provided for the proposed algorithm. Finally, its advantages are verified by theoretical analysis and experimental results.

Fuzzy Controller of Three-Inertia Resonance System designed by Differential Evolution

  • Ikeda, Hidehiro;Hanamoto, Tsuyoshi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.184-189
    • /
    • 2014
  • In this paper, a new design method of vibration suppression controller for multi-inertia (especially, 3-ineritia) resonance systems is proposed. The controller consists of a digital fuzzy controller for speed loop and a digital PI controller for current minor loop. The three scaling factor of the fuzzy controller and two PI controller gains are determined by Differential Evolution (DE). The DE is one of optimization techniques and a kind of evolutionary computation technique. In this paper, we have applied the DE/rand/1/bin strategy to design the optimal controller parameters. Comparing with the conventional design algorithm, the proposed method is able to shorten the time of the controller design to a large extent and to obtain accurate results. Finally, we confirmed the effectiveness of the proposal method by the computer simulations.

The clinical usefulness of fat suppression by chemical shift selective(CHESS) pulse in MRI (MRI에서 화학적 이동 선택(CHESS) pulse에 의한 지방소거의 임상적 유용성)

  • Han, Man-Seok;Yang, Hae-Sool;Jin, Kyung-Soo;Eo, Ik-Soo;Cho, Dong-Heon
    • The KIPS Transactions:PartB
    • /
    • v.14B no.6
    • /
    • pp.431-436
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has chemical shift phenomenon between fat and water, and the phenomenon has influence on structure enclosed by fat. Strong signals emitted from fat often generate false artefact, which reflects the importance of fat suppression techniques. There have been a number of researches on fat suppression techniques, but using fat suppression method alone in MRI can cause difficultproblems in diagnosis. This paper aims to study a fat suppression method by Chemical Shift Selective saturation(CHESS). This research describes the theoretical background and the experiment on water and fat phantom with MR instruments. In the experiment, CHESS pulse was designed by utilising Matlap program, and the pulse diagram was generated for the Pre-saturation process. The experiment using water and fat phantom was applied to C-spine, L-spine and Breast, and produced successful fat suppression results. This experiment has proved that the CHESSpulse fat suppression is a very helpful technique in diagnosing medical imaging. This method is a robust and useful technique for both clinical and basic investigators..(Experiment with Chungnam national university hospital G.E 1.5T MR)

A Debate on the Use of Presaturation Method in NMR for Structure Determination of Polypeptides in $H_2O$

  • Lee, Chulhyun;Yi, Gwan-Su;Kim, Eun-Hee;Lee, Jo-Woong;Chagjoon Cheong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.1
    • /
    • pp.21-29
    • /
    • 1997
  • Three typical solvent suppression methods employed for measuring the NOE data that are used for structure determination of polypeptides by modeling were discussed and compared with one another. In the experiments with several peptides composed of 10 to 65 amino acids the presaturation method was found to give severely distorted signal intensities of exchangeable protons, thus making the results based on this method much less reliable.

  • PDF

An application of wavelet transform toward noisy NMR peak suppression

  • Kim, Daesung;Kim, Dai-Gyoung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.6 no.1
    • /
    • pp.12-19
    • /
    • 2002
  • A shift-averaged Haar wavelet transform was introduced as a new and excellent tool to distinguish real peaks from the noise contaminated NMR signals. It is based on Haar wavelet transform and translation-invariant denoising process. Donoho's universal threshold was newly introduced to the shift-averaged Haar wavelet transform for the purpose of automated noise suppression, and was quantitatively compared with the conventional uniform threshold method in terms or threshold and signal to noise ratio (SNR). New algorithm was combined with a routine to suppress a large solvent peak by singular value decomposition (SVD). Combined algorithm was applied to the real spectrum that containing large solvent peak.

  • PDF

Noise Suppression of NMR Signal by Piecewise Polynomial Truncated Singular Value Decomposition

  • Kim, Daesung;Youngdo Won;Hoshik Won
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.4 no.2
    • /
    • pp.116-124
    • /
    • 2000
  • Singular value decomposition (SVD) has been used during past few decades in the advanced NMR data processing and in many applicable areas. A new modified SVD, piecewise polynomial truncated SVD (PPTSVD) was developed far the large solvent peak suppression and noise elimination in U signal processing. PPTSVD consists of two algorithms of truncated SVD (TSVD) and L$_1$ problems. In TSVD, some unwanted large solvent peaks and noises are suppressed with a certain son threshold value while signal and noise in raw data are resolved and eliminated out in L$_1$ problem routine. The advantage of the current PPTSVD method compared to many SVD methods is to give the better S/N ratio in spectrum, and less time consuming job that can be applicable to multidimensional NMR data processing.

  • PDF

Chest Wall Lipogranuloma after Hydrogel Implant Rupture: Case Report

  • Park, So Yoon;Han, Boo-Kyung;Cho, Eun Yoon;Bang, Sa-Ik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.191-195
    • /
    • 2015
  • We present a 53-year-old woman with a large chest wall mass in the interpectoral space, which was eventually confirmed as a lipogranuloma resulting from hydrogel implant rupture. Ultrasonography (US) showed reduced implant volume with surrounding peri-implant fluid collection, suggesting the possibility of implant rupture. A heterogeneously hypoechoic mass was found between the pectoralis major and minor muscles adjacent to the ruptured implant. On magnetic resonance imaging (MRI), there was a large mass in the left interpectoral space of the upper inner chest wall. The mass showed slightly high signal intensity (SI) on pre-contrast T1-weighted image (WI) with mixed iso and high SI on T2-WI. The signal of the mass was suppressed using the water suppression technique but not with the fat suppression technique on T2-WI. The mass showed diffuse enhancement upon contrast enhancement. The enhancing kinetics showed persistent enhancement pattern. US-guided core needle biopsy revealed a lipogranuloma and removal confirmed a ruptured PIP hydrogel implant.

Efficient baseline suppression via TIP and modified DEPTH

  • Hyun, Namgoong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.26 no.4
    • /
    • pp.51-58
    • /
    • 2022
  • The baseline flattened NMR spectrum has been achieved by several methodologies including pulse manipulation with a series of phase cycling. The background signal inherent in the probe is also main source of baseline distortion both in solution and solid NMR. The simple direct polarization with 90° pulse flipping the magnetization from the z-axis onto the receiver coil requires the strong rf pulse enough to encompass the wide frequency range to excite the resonance of interest nuclei. Albeit the perfect polarization 90° pulse, the signal from the unwanted magnetic fields such as background signal can not be completely suppressed by suitable phase cycling. Moreover, slowly baseline wiggling signal from the low 𝛾 nuclei is not easy to eliminate with multiple pulse manipulation. So there is still need to contrive the new scheme for that purpose in an adroit manner. In this article new triple pulse excitation schemes for TIP and modified DEPTH pulse sequence are analytically examined in terms of arbitrary phase and flip angle of pulse. The suitable phase cycling for these pulse trains is necessary for the good sensitivity and resolution of the spectrum. It is observed that the 13C sensitivity TIP experiment is almost equal to the CP/MAS with modified DEPTH sequence, both of which are applicable to both solid and solution state NMR.

Novel Oscillator Incorporating a Compact Microstrip Ring Type Resonant Cell with High Efficiency and Superior Harmonic Characteristics

  • Hwang Cheol-Gyu;Myung Noh-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.2
    • /
    • pp.92-96
    • /
    • 2005
  • This paper presents a novel microwave oscillator incorporating a simple microstrip ring type resonant cell as its terminating resonance component. Reduced chip size, higher dc-ac power efficiency, superior harmonic characteristics can be achieved from the introduction of a compact microstrip ring resonator cell. The oscillator provides a second harmonic suppression of 26.51 dB and the output power of 2.046 dBm at 2.11 GHz.