• Title/Summary/Keyword: Resonance Coil

검색결과 375건 처리시간 0.022초

스트레인 게이지 변위 추정기를 사용한 유동공진 가진기 개발 (The Development of Vibration Exciter Using Strain Displacement Estimator for Flow Resonance)

  • 최재혁;남윤수
    • 산업기술연구
    • /
    • 제21권B호
    • /
    • pp.125-132
    • /
    • 2001
  • Heat dissipation technology using flow resonant phenomenon is a kind of new concept in heat transfer area. A vibration exciter is needed to generate air turbulence which has the natural shedding frequency of heat system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator. An analytical dynamic model for this mechanical vibration exciter is presented and its' validity is verified by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, the vibration exciter using strain displacement estimator is developed. And in the experiment, the feedback control is used. During the experimental verification phase, it turns out the high modal resonant characteristics of vibrating plate are the major barrier against obtaining a high bandwidth vibration exciter.

  • PDF

고균일 자계발생용 초전도 능동차폐 마그네트의 설계에 관한 연구 (A Design Approach for High Homogeneity Superconducting Magnet with Superconducting Active Shield)

  • 이광호;김성도;조윤현;이재복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.151-153
    • /
    • 1996
  • An optimal design approach is presented for high homogeneity superconducting magnet with superconducting active shield especially for use in magnetic resonance imaging system. This paper is investigated phenomena for the stray magnetic field to get a basic reduction techniques of the unwanted stray magnetic field from the magnet. The present method obtains optimal coil configuration considering constraints for magnetic field homogeneity and leakage field.

  • PDF

휴대폰용 일체형 음향 및 진동 발생장치 개발을 위한 연구 (Study on the Development of Integrated Vibration and Sound Generator)

  • 신태명;안진철
    • 한국소음진동공학회논문집
    • /
    • 제13권11호
    • /
    • pp.875-881
    • /
    • 2003
  • The received signal of a mobile phone is normally sensed through two independent means which are the sound generation of a speaker and vibration generation of a vibration motor. As an improvement scheme to meet the consumer's demand on weight reduction and miniaturization of a mobile phone, the design and development of an integrated vibration and sound generating device are performed in this research. To this purpose, the optimal shapes of the voice coil. the permanent magnet and the vibration plate are designed, and the excitation force applied to the vibration system of the new device is estimated and verified through theoretical analyses, computer simulation, and experiments using an expanded model. In addition, vibration performance comparison of the device with the existing vibration motor is performed, and from the overall process, therefore, the method and procedure for the vibration performance analysis of the integrated vibration and sound generating device are established.

Design and Fabrication of Low Frequency Driven Energy Harvester Using Electromagnetic Conversion

  • Lee, Byung-Chul;Chung, Gwiy-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권3호
    • /
    • pp.143-147
    • /
    • 2013
  • This paper describes a low frequency driven electromagnetic energy harvester (EMEH) which consists of a thin flame resistant (FR-4) planar spring, NdFeB permanent magnets, and a copper coil. The FR-4 spring was fabricated using a desk computer numerical control (CNC) 3D modeling machine. Mathematical modeling and ANSYS finite element analysis (FEA) were used totheoretically investigate the mechanical properties of the spring mass system. The proposed EMEH generates a maximum power of 65.33 ${\mu}W$ at a resonance frequency of 8 Hz with an acceleration of 0.2 g (1 g = 9.8 $m/s^2$) and a superior normalized power density (NPD) of 77 ${\mu}W/cm^3{\cdot}g^2$.

Development of Spectrometer with 1 GFLOPs Digital Signal Processors

  • 김휴정;정민영;김치영;고광혁;이상철;이흥규;안창범
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.178-178
    • /
    • 2001
  • 목적: 본 연구에서는 초당 $10^{9}$ 부동점 연산이 가능한 Texas Instrument사의 TMS320C6701 DSP를 이용하여 연속적으로 변하는 경사자계를 real-time으로 계산하여 후, 4 채널의 phase array 코일을 이용하여 영상을 얻은 후 빠른 재구성을 통하여 영상을 확인할 수 있는 spectrometer를 개발하였다. 대상 및 방법: 실시간 구현을 위하여 DSP 보드에 Texas Instruments(Tl)사의 TMS320C6701을 장착하였다. Transmitter, receiver, 그리고 gradient를 담당하는 DSP 보드들과 이들과 연결되어 rf modulation, gradient waveform을 만드는 analog board와 phased array coil을 위한 4 채널까지 측정이 가능한 receiver board로 구성하였다. Gradient 보드의 경우 각 경사자계의 채널(Gx, Gy, Gz)의 sampling points를 real-time으로 각각 계산함으로써 blipped-EPI 뿐만 아니라, 경사자계 파형이 연속적으로 변화하는 spiral-EPI의 실험도 가능하게 하였다.

  • PDF

Combined BOLD fMRI and Transcranial Magnetic Stimulation Study: Evaluation of Ipsilateral Motor Pathway of Stroke Patients

  • 배성진;장용민;장성호;변우목;강덕식
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.104-104
    • /
    • 2001
  • Purpose: In this study, we investigated the possible motor pathways of hemiplegic stroke patients usin combined TMS and BOLD fMRI approach and evaluated the correlation between TMS a fMRI methods. Method: Four subjects, who demonstrated left hemiplegia after stroke, are included. TMS was performed using a Dantec Mag2 stimulator (Dantec Company, USA) in single puls mode with figure eight-shaped coil. Following TMS localization, The BOLD T2*-weight images were acquired with echo planar imaging sequence (TR = 1.2 sec, TE = 60 msec, and flip angle = 90). Motor activation was studied by means of a repetitive fing flexion-extension task. The stimulation protocol comprised 10 cycles of alternating activati and rest (10 images per cycle). Total 60 cycles were performed and each cycle take abou 1.5 sec. The resulting images were then analyzed with STIMULATE (CMRR, U, o Minnesota) to generate functional maps using a student t-test (p < 0.0005) and cluste analysis.

  • PDF

Development of Surface RF Coil with extremely short RF penetration depth

  • 김대흥;김은주;정은기;이삼현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.147-147
    • /
    • 2001
  • 목적: RF 자기장이 존재하는 공간이 좁을수록 신호 대 잡음비가 증가한다. 이것을 이용하여, 기존의 표면 코일보다 RF 자기장의 공간을 좁혀서 코일 근방에서 신호 대 잡음비를 개선할 수 있는 표면 코일을 개발한다. 대상 및 방법: 기존의 표면 코일의 RF 자기장은 쌍극자(Dipole) 자기장 형태이다. 쌍극자 모드는 자기장의 세기가 1/r$^3$로 감소한다 하지만 자기장을 사중극자(Quadrupole) 형태도 발생시키면, 1/r$^{5}$ 로 감소하게 되어, 극자(pole)로부터 먼 곳에서는 자기장의 감소가 매우 급격히 일어난다. 극자 근방에서는 쌍극자와 사중극자 자기장의 세기 차이가 거의 없다. 이런 원리들을 이용하여 표면코일의 형태를 사중극자 자기장이 발생하도록 제작하여, 코일로부터 먼 곳의 신호는 코일에 검출되지 못하게 하였다. 그러므로 신호 대 잡음비에 큰 이득을 볼 수 있다.

  • PDF

무선 상태감시 시스템용 진동 기반 에너지 획득 장치 (Vibration-based Energy Harvester for Wireless Condition Monitoring System)

  • 조성원;손종덕;양보석;최병근
    • 한국소음진동공학회논문집
    • /
    • 제19권4호
    • /
    • pp.393-399
    • /
    • 2009
  • Historically, industrial condition monitoring has been performed by costly hard-wired sensors or infrequent checks by maintenance personnel equipped with hand held monitoring equipment. Self- powered wireless condition monitoring systems provides on-line monitoring of critical plant and machinery providing major operating cost benefits. A vibration energy harvester(VEH) is a device that converts kinetic energy occurred by machine vibration into useable electrical energy. Using VEHs to power wireless monitoring systems can yield significant benefits: increased reliability, lower life time costs and no battery disposal issues, etc. This paper proposes the novel prototype design and manufacturing of a VEH that can eliminate the effect by failed batteries.

Compact ECR plasma장치의 제작 및 특성 연구 (Study on the Fabrication and Characterization of Compact ECR Plasma System)

  • 윤민기;박원일;남기석;이기방
    • 전자공학회논문지A
    • /
    • 제31A권4호
    • /
    • pp.84-91
    • /
    • 1994
  • A compact electron cyclotron resonance(ECR) plasma system composed of a microwave generator and a magnet coil was fabricated. A Langmuir single probe was used to investigate the plasma characteristics of the system through I-V measurements. The performance of the compact ECR plasma system was tested for the case of silicon etching reaction with $CF_{4}/O_{2}$(30%) mixed gas. Electron density and etch rate increased to maximum values and then decreased with increasing argon gas pressure, but electron temperature changed in the opposite way. The electron density and the electron temperature of argon gas plasma were 0.85${\times}~5.5{\times}10^{10}cm^{-3}$ and 4.5~6.0 eV, respectively, in the pressure range from $3{\times}10^{4}$ to 0.05Torr. The etch rate reached a maximum value at the position of 2.5cm from the bottom of plasma cavity. Etch rate uniformity was $\pm$6% across 6cm wafer. Anisotropic index was 0.75 at 1.5${\times}10^{-4}$Torr.

  • PDF

핵자기공명(NMR) 응용을 위한 고자장 초전도 마그네트의 최적화 설계 (High Field Superconducting Magnet Optimal Design for Nuclear Magnetic Resonance (NMR) Applications)

  • 고락길;조영식;권영길;진홍범;배준한;심기덕;류강식
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.150-153
    • /
    • 2000
  • NMR researches are required high field and high homogeneous super-conducting magnet. Thus superconducting magnets for NMR applications are designed with minimization of coil winding volume satisfied constraints such as field strength, field homogeneity, etc. In this paper, we are discussed optimal design of high field super-conducting magnet for NMR applications. For a design example, we designed unshielded superconducting magnet for 600MHz NMR spectrometer with 100mm room temperature bore size and obtained 14.1011[T] field strength and 1.33 ppm field homogeneity.

  • PDF