• 제목/요약/키워드: Resistive Force

검색결과 46건 처리시간 0.033초

Nanoscale Probing of Switching Behaviors of Pt Nanodisk on STO Substrates with Conductive Atomic Force Microscopy

  • Lee, Hyunsoo;Kim, Haeri;Van, Trong Nghia;Kim, Dong Wook;Park, Jeong Young
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.597-597
    • /
    • 2013
  • The resistive switching behaviors of Pt nanodisk on Nb-doped SrTiO3 single-crystal have been studied with conductive atomic force microscopy in ultra-high vacuum. The nanometer sizes of Pt disks were formed by using self-assembled patterns of silica nanospheres on Nb-doped SrTiO3 single-crystal semiconductor film using the Langmuir-Blodgett, followed by the metal deposition with e-beam evaporation. The conductance images shows the spatial mapping of the current flowing from the TiN coated AFM probe to Pt nanodisk surface on Nb:STO single-crystal substrate, that was simultaneously obtained with topography. The bipolar resistive switching behaviors of Pt nanodisk on Nb:STO single-crystal junctions was observed. By measuring the current-voltage spectroscopy after the forming process, we found that switching behavior depends on the charging and discharging of interface trap state that exhibit the high resistive state (HRS) and low resistive state (LRS), respectively. The results suggest that the bipolar resistive switching of Pt/Nb:STO single-crystal junctions can be performed without the electrochemical redox reaction between tip and sample with the potential application of nanometer scale resistive switching devices.

  • PDF

저항운동치료 처방에 관한 연구 (A Study of Resistive Therapeutic Exercise Prescription)

  • 배성수;김태숙;김은주
    • The Journal of Korean Physical Therapy
    • /
    • 제11권1호
    • /
    • pp.149-156
    • /
    • 1999
  • Resistive therapeutic exercise prescription goal is to improve functional performance and capabilities through the development of increased muscular strengh endurance or power. Resistance can be applied to either dynamic or static muscle contractions. Resistive therapeutic exorcise can be carried nut concentrically, eccentrically, isometrically, isokinetically. Neurodevelopmental treatment has not resistive therapeutic exercise concept. But proprioceptive neuromuscular facilitate techniques have resistive therapeutic exercise concept with pattens and techniques. It is aid muscle contraction, motor control and increase strength. Manual muscle testing will help the therapist establish a qualitative and quantitative baseline level of strength. Manual resistance maybe applied a against controlled lengthening contraction re static contraction of a muscle. A repetition maximum is not easy to calculate and is not the most accurate method available today to measure strength before of after a resistive therapeutic exercise program. Oddvar Holten Diagram is essy to calculate and is the most accurate method available today to measure strength before of after a resistive therapeutic exercise program. Plyometric training emphasize the development of muscular power and coordination. Quick bursts of force in functional movement patterns are often necessary of a patient is to return to high-demand occupational, recreational or sports related activities.

  • PDF

Slender piezoelectric beams with resistive-inductive electrodes - modeling and axial wave propagation

  • Schoeftner, Juergen;Buchberger, Gerda;Benjeddou, Ayech
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.335-354
    • /
    • 2016
  • This contribution presents an extended one-dimensional theory for piezoelectric beam-type structures with non-ideal electrodes. For these types of electrodes the equipotential area condition is not satisfied. The main motivation of our research is originated from passive vibration control: when an elastic structure is covered by several piezoelectric patches that are linked via resistances and inductances, vibrational energy is efficiently dissipated if the electric network is properly designed. Assuming infinitely small piezoelectric patches that are connected by an infinite number of electrical, in particular resistive and inductive elements, one obtains the Telegrapher's equation for the voltage across the piezoelectric transducer. Embedding this outcome into the framework of Bernoulli-Euler, the final equations are coupled to the wave equations for the longitudinal motion of a bar and to the partial differential equations for the lateral motion of the beam. We present results for the wave propagation of a longitudinal bar for several types of electrode properties. The frequency spectra are computed (phase angle, wave number, wave speed), which point out the effect of resistive and inductive electrodes on wave characteristics. Our results show that electrical damping due to the resistivity of the electrodes is different from internal (=strain velocity dependent) or external (=velocity dependent) mechanical damping. Finally, results are presented, when the structure is excited by a harmonic single force, yielding that resistive-inductive electrodes are suitable candidates for passive vibration control that might be of great interest for practical applications in the future.

Resistive Switching Effects of Zinc Silicate for Nonvolatile Memory Applications

  • Im, Minho;Kim, Jisoo;Park, Kyoungwan;Sok, Junghyun
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.348-352
    • /
    • 2022
  • Resistive switching behaviors of a co-sputtered zinc silicate thin film (ZnO and SiO2 targets) have been investigated. We fabricated an Ag/ZnSiOx/highly doped n-type Si substrate device by using an RF magnetron sputter system. X-ray diffraction pattern (XRD) indicated that the Zn2SiO4 was formed by a post annealing process. A unique morphology was observed by scanning electron microscope (SEM) and atomic force microscope (AFM). As a result of annealing process, 50 nm sized nano clusters were formed spontaneously in 200~300 nm sized grains. The device showed a unipolar resistive switching process. The average value of the ratio of the resistance change between the high resistance state (HRS) and the low resistance state (LRS) was about 106 when the readout voltage (0.5 V) was achieved. Resistance ratio is not degraded during 50 switching cycles. The conduction mechanisms were explained by using Ohmic conduction for the LRS and Schottky emission for the HRS.

다양한 선재 조합에 따른 이종 초전도 스위치의 특성 실험 및 분석 (Experimental and Analytical Studies on the Characteristics of Fast Switch in Combinations of Various Superconducting Tapes)

  • 이지호;김영재;나진배;최석진;장재영;황영진;김진섭;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.31-35
    • /
    • 2011
  • A Hybrid Fault Current Limiter(FCL) which has more advantages in fast response and thermal characteristics than a simple resistive FCL had been proposed by our group. The Hybrid FCL consists of a resistive FCL for the magnitude of the first peak of fault current, and a fast switch for detecting fault current and generating the repulsive force within a cycle in fault situation. In ideal case, the impedance of the fast switch wound with two other kinds of HTS tape is negligibly zero in normal operation. But, during the fault situation, each HTS tape has different quench characteristics because of asymmetric current distribution. And this phenomenon causes effective flux and this flux opens the switch through the repulsive force applied to a metal plate of the fast switch. The magnitude of the repulsive force affects the switching characteristics of the fast switch. It should be large enough to raise the metal plate up. Otherwise the arc re-out break which are caused by not enough repulsive force to raise the metal plate up can cause unintended operation of the fast switch. In this paper, the numerical calculation of the repulsive force applied to the metal plate of the fast switch in various combinations of HTS tapes was performed by using the short-circuit test and finite element method.

다기능 재활운동을 위한 힘 센서가 없는 상지 재활 로봇의 힘 제어 (Sensorless Force Control with Observer for Multi-functional Upper Limb Rehabilitation Robot)

  • 최정현;오세훈;안진웅
    • 로봇학회논문지
    • /
    • 제12권3호
    • /
    • pp.356-364
    • /
    • 2017
  • This paper presents a force control based on the observer without taking any force or torque measurement from the robot which allows realizing more stable and robust human robot interaction for the developed multi-functional upper limb rehabilitation robot. The robot has four functional training modes which can be classified by the human robot interaction types: passive, active, assistive, and resistive mode. The proposed observer consists of internal disturbance observer and external force observer for distinctive performance evaluation. Since four training modes can be quantitatively identified as impedance variation, position-based impedance control with feedback and feedforward controller was applied to the assistive training mode. The results showed that the proposed sensorless observer estimated cleaner and more accurate force compared to the force sensor and the impedance controller embedded with the proposed observer completed the assistive training mode safely and properly.

Contractile Force Measurements of Cardiac Myocytes Using a Micro-manipulation System

  • Park Suk-Ho;Ryu Seok-Kyu;Ryu Seok-Chang;Kim Deok-Ho;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.668-674
    • /
    • 2006
  • In order to develop a cell based robot, we present a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source. The proposed measurement system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recording system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitudes of the contractile force of each cardiac myocyte under different conditions were compared. From the quantitative experimental results, we could estimate that the force of cardiac myocytes is about $20\sim40{\mu}N$, and show that there are differences between the control cells and the micro-patterned cells.

광화학증착법에 의한 직접패턴 비정질 TiOx 박막의 제조 및 저항변화 특성 (Resistive Switching Characteristic of Direct-patternable Amorphous TiOx Film by Photochemical Metal-organic Deposition)

  • 황윤경;이우영;이세진;이홍섭
    • 마이크로전자및패키징학회지
    • /
    • 제27권1호
    • /
    • pp.25-29
    • /
    • 2020
  • 광화학증착법 (PMOD; photochemical metal-organic deposition)을 이용하여 photoresist 및 etching 공정없이 pattern 된 TiOx resistive switching (RS) 소자를 제작 및 그 특성을 평가하였다. Ti(IV) 2-ethylhexanoate를 출발물질로 사용하였으며 UV 노출시간 10 min에 광화학반응이 완료됨을 FTIR 분석을 통하여 확인하였다. 200 ℃ 이하 저온공정에서 직접패턴 된 20 nm 두께의 비정질 TiOx 박막의 균일한 두께의 패턴형성을 Atomic Force Microscopy를 통하여 확인하였다. 별도의 상형성을 위한 후 열처리 공정 없이 4 ㎛ 선폭의 전극위에 형성된 20 nm 두께의 비정질 TiOx RS 소자는 4V 동작전압에서 on/off ratio 20의 forming-less RS 특성을 나타내었다. Electrochemical migration에 영향을 미치는 grain boundary가 없어 소자간 신뢰성 향상이 기대되며, flexible 기판 또는 저온공정이 요구되는 메모리 소자 공정에서 PMOD 공정이 응용될 수 있음을 보여준다. Selector를 이용하여 crossbar array 구조를 도입할 경우 매우 간단한 구조의 저비용 메모리 소자를 구현할 수 있을 것으로 기대 된다.

점성유체 중에 회전하는 스프링의 추진적 거동에 관한 수치해석 모델 (Numerical Model of Propulsive Behavior of a Rotating Spring in Viscous Fluid)

  • 최원열;서용권;강상모
    • 대한기계학회논문집B
    • /
    • 제39권6호
    • /
    • pp.497-504
    • /
    • 2015
  • 본 논문에서는 박테리아 편모를 모사한 스프링 모델을 이용하여 박테리아의 편모의 추진적 거동에 관한 연구를 수행하였다. 본 해석에서는 상용프로그램을 사용하였으며, 별도의 회전영역 설정에 따른 수치기법의 타당성 확인과 더불어 파라미터 연구를 수행하였다. 수치해석 결과는 전반적으로 Resistive force theory와는 잘 일치하지 않았지만, Slender body theory와는 잘 일치하였다. 그리고 스프링의 회전속도, 피치, 나선반경 및 유체의 점성의 영향을 확인하였다. 또한 벽과의 거리에 따른 효과도 분석하였다.