• 제목/요약/키워드: Resistant performance

검색결과 692건 처리시간 0.025초

Seismic performance analysis of steel-brace RC frame using topology optimization

  • Qiao, Shengfang;Liang, Huqing;Tang, Mengxiong;Wang, Wanying;Hu, Hesong
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.417-432
    • /
    • 2019
  • Seismic performance analysis of steel-brace reinforced concrete (RC) frame using topology optimization in highly seismic region was discussed in this research. Topology optimization based on truss-like material model was used, which was to minimum volume in full-stress method. Optimized bracing systems of low-rise, mid-rise and high-rise RC frames were established, and optimized bracing systems of substructure were also gained under different constraint conditions. Thereafter, different structure models based on optimized bracing systems were proposed and applied. Last, structural strength, structural stiffness, structural ductility, collapse resistant capacity, collapse probability and demolition probability were studied. Moreover, the brace buckling was discussed. The results show that bracing system of RC frame could be derived using topology optimization, and bracing system based on truss-like model could help to resolve numerical instabilities. Bracing system of topology optimization was more effective to enhance structural stiffness and strength, especially in mid-rise and high-rise frames. Moreover, bracing system of topology optimization contributes to increase collapse resistant capacity, as well as reduces collapse probability and accumulated demolition probability. However, brace buckling might weaken beneficial effects.

국내 현장방염 시공의 실태분석 연구 (A Study on the On-site Flame Resistant Treatment in Domestic)

  • 김황진;이성은;오규형
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.33-38
    • /
    • 2011
  • 본 연구는 초기 착화지연으로 화재예방에 중요한 역할을 담당하는 방염처리제도에 대한 실태 분석연구로서 현장에서 발생하는 여러 문제점들을 각 시도 소방공무원과 방염업자들과의 회의 및 시공현장 방문을 통해 분석하였다. 분석결과 첫 째, 수요가 작은 시장에서 너무 많은 업체들이 경쟁을 하고 있고 이로 인해 방염에 대한 전문성이 없는 일부 업자들은 원가절감을 위해 부실시공을 하는 등의 문제가 발생하고 있으며 둘 째, 현재 실시되고 있는 현장방염처리 검사제도는 검사자가 현장에서 직접 성능검사를 실시하지 못하고 시공자가 제출한 샘플로 방염성능검사를 실시하기 때문에 시료채취의 문제점과 제출된 시료의 신뢰성 및 현장의 방염성능 확보에 의문을 갖는 등의 문제가 발생하고 있다.

Separation Characteristic of Shatter Resistant Sesame After Threshing

  • Noh, Hyun Kwon
    • Journal of Biosystems Engineering
    • /
    • 제39권4호
    • /
    • pp.299-303
    • /
    • 2014
  • Purpose: This study set out to develop a machine for separating shatter-resistant sesame after threshing. Methods: Three grades of sieve and different blower speeds were tested for a separation system that had been designed specifically for shatter-resistant sesame. Performance tests were run to evaluate the sieve and blower systems in terms of the sesame separation and loss ratios. Results: Tests of the first separation stage using the sieve system revealed the optimum sieve perforation size to be 5 mm. Tests of the second separation stage using the blower system identified the optimum blower speed as being 220 rpm. The optimum separation and loss ratios, of 96.5% and 3.5%, respectively, were obtained at a blower speed of 220 rpm. Conclusions: These results will be useful for the design, construction, and operation of threshing harvesters. For shatter-resistant sesame, an optimum blower speed of 220 rpm was identified.

커튼월 층간 화재확산방지구조 적용을 위한 경량무기발포 세라믹보드의 부착강도 (Bond Strength of Light-weight Inorganic Ceramic Board for Fire Resistant Curtain-wall System)

  • 신현욱;송훈;추용식;이종규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.214-215
    • /
    • 2014
  • Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. This study is explain fire resistance performance of the curtain walls. And focused on bond strength of light-weight inorganic ceramic board in high temperature for fire resistant curtain-wall system. From the result, curtain-wall system high fire resistant using the light-weight inorganic ceramic board.

  • PDF

Performance Improvement of Nonformaldehyde Wrinkle Resistant Finished Cotton Fabrics Treated with Dialdehydes

  • Park, Hyung-Min;Kim, Yong-Min
    • Fibers and Polymers
    • /
    • 제2권4호
    • /
    • pp.190-195
    • /
    • 2001
  • Additives, such as sodium perborate and borax, were examined in dialdehyde wrinkle resistant finishing of cotton. Results indicated that the whiteness index(WI) of cotton treated with dialdehyde and additive showed about 90% of WI of the untreated cotton but with decrease in wrinkle recovery angle (WRA) due to inhibition effect of these additives. Effect of additive on the WRA reduction was more prominent with glutaraldehyde than with glyoxal. Reduction in WRA of cotton treated with both dialdehydes and boron compound was minimized by simultaneous addition of formic acid in the bath. Addition of formic acid was also generally beneficial in maintaining WI retentions after 8 months storage. Furthermore, boron compounds were also effective in improving retentions of mechanical properties. By FTIR analysis the residual aldehyde group was detected on the dialdehyde-finished cotton, whereas no peak was shown by addition of boron compounds. This suggested that the residual aldehyde group was a main cause of fabric yellowing on the dialdehyde-finished cotton. Dialhehyde with boron compound, therefore, can be used to replace a conventional formaldehyde-containing wrinkle resistant finishing of cotton.

  • PDF

내화유리를 적용한 강재 유리벽의 내화성능 평가 (The Evaluation of Fire-Resistant Performance of the Non-bearing Steel Wall Using Fire Resistant Glass)

  • 이재승;임현창;양승조
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.72-81
    • /
    • 2018
  • 방화구획 내 벽체에는 콘크리트, 조립식 패널, 건식벽체 등을 사용한 내화구조가 주로 적용되고 있으나 근래에 들어 시야 확보 및 미적 관점에 대한 관심이 증가하여 유리로 구성된 벽체의 수요가 발생하고 있다. 본 연구에서는 차열 유리를 적용한 스틸 내화벽체에 관한 것으로써 내부 방화구획에 적용 가능한 60분 내화벽체와 외부 벽체 및 커튼월에 적용 가능한 90분 내화벽체에 대하여 내화시험 및 성능분석을 수행하였다. 시험 결과, 각 시험체의 요구 내화성능을 충족하는 것으로 나타났으며, 추가적으로 유한요소해석을 통한 유리벽체의 내화성능을 평가하였으며 그 결과 1차적으로 시험체의 내화성능을 예측하는 것이 가능한 것으로 판단되었다.

뿜칠 피복 원형 철골구조의 비재하 내화성능 평가용 시험체 제안을 위한 연구 (Study of the Standard Testing Specifications for a Non-loading Performance Evaluation of Coating Material-sprayed Circular Steel Structures)

  • 옥치열;김재준
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.7-15
    • /
    • 2016
  • 단면형상계수는 세계적으로 흔하게 활용되는 공학적 내화구조 성능평가 방법이지만 국내의 경우 단면형상계수의 적용을 위한 제도가 아직 마련되어 있지 못하다. 실제 우리나라의 대부분의 철골조 건축물에서 원형 강관의 사용을 흔히 볼 수 있으나, 인정기관으로부터 성능을 인정받은 뿜칠 피복 철골 보 및 기둥은 대부분이 H형강으로 한정되어 있다. 비재하 시험의 특성상 H형강은 관련규정에 따른 시험규격으로 부재에 대한 평가를 수행하여 크기의 제한 없이 인정범위가 부여되나, 이형 강관의 경우는 형상별로 별도의 내화성능에 대한 인정을 받아야 한다. 본 연구에서는 합리적인 내화구조의 인정범위를 설정할 수 있도록 단면형상계수를 활용하여 뿜칠 피복재의 원형 강관의 적용을 위한 표준 시험체 규격을 제시하고자 한다.

방폭설계의 이해 및 일반하중에 대해 설계된 건축물의 방폭성능 평가 (Understanding of Blast Resistant Design and Performance Evaluation of a Building designed for Conventional Loads)

  • 홍종국
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권4호
    • /
    • pp.83-90
    • /
    • 2018
  • 전 세계적으로 테러의 위협이 가중되고 일반 상업건축에 대한 방폭설계의 요구가 증가하고 있는 현실을 직시하여, 본 연구에서는 기본적인 방폭설계의 개념을 정립하고 실제 설계사례를 통하여 방폭성능을 평가하는데 목표를 두고 있다. 비록 지진하중과 폭파하중에는 많은 차이점이 있지만, 그 설계법은 구조물의 소성거동을 허용하고 연성을 갖도록 설계한다는 점에서 유사하다. 본 연구에서 제시된 대상 건물에 대한 방폭성능 평가를 통하여, 일반하중에 대하여 잘 설계된 건물은 어느 정도 수준의 방폭성능을 확보하는 것으로 나타났다. 그러나 구조물에 작용하는 폭파하중은 무기의 종류, 등가의 TNT량, 폭발점에서 목표물까지의 최단거리인 촛점거리 등에 따라 달라지기 때문에 일반화하기에는 무리가 있다. 희생구조물을 배치하거나 예상되는 폭발점에서 주요 구조부재까지의 촛점거리를 일정수준 이상으로 유지하는 건축 계획적인 노력은 건물의 방폭성능을 향상시킬 수 있는 쉽고 효과적인 방법이다.

중소병원 대상 다제내성균 감염관리 시뮬레이션 프로그램 개발 및 적용 (Development and Application a Multidrug Resistant Organisms Infection Control Simulation Program for Small and Medium-sized Hospital)

  • 이미향;김재연
    • 디지털융복합연구
    • /
    • 제19권4호
    • /
    • pp.159-166
    • /
    • 2021
  • 본 연구는 중소병원 간호사를 대상으로 다제내성균 감염관리 시뮬레이션 프로그램을 개발하고 개발된 다제내성균 감염관리 시뮬레이션 교육 프로그램의 효과를 평가하기 위해 시도되었다. 본 연구는 중소병원에 근무하는 간호사 33명을 대상으로 시행한 단일군 전·후 실험설계연구이다. 수집된 자료는 IBM SPSS 21.0 프로그램을 이용하여 분석하였으며 대상자의 일반적 특성, 다제내성균 감염관리 지식과 수행도는 기술통계 분석하였고 프로그램 적용 전후 지식과 수행도의 차이는 paired t-test로 분석하였다. 연구결과 시뮬레이션 프로그램 적용 후 간호사의 다제내성균 감염관리 지식(t=-10.764, p<.001)과 감염관리 수행도(t=-4.215, p<.001)가 통계적으로 유의하게 높아졌다. 의료기관 내 다제내성균 전파 차단 및 유행발생을 예방하기 위해 간호사의 감염관리 지식과 수행도 향상이 중요하므로 향후 다양한 시뮬레이션 프로그램 개발이 필요하다.

복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구 (Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar)

  • 박금성;배규웅;강현식;임서형
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.109-116
    • /
    • 2007
  • 본 논문의 목적은 경량기포모르터를 충전한 스틸스터드와 복합스터드 내력벽체의 내화성능을 KS규준에 따라 평가하는데 있다. 주거용과 상업용 건물의 최소 내화 요구시간은 2시간이다. 시험 결과로부터 스틸 스터드와 복합스터드에 경량기포 모르터를 충전한 두 시험체 모두 2시간 내화 성능을 만족하는 것으로 나타났다. 또한 복합스터드 패널 시험체의 경우 내화 성능면에서 스틸 스터드 패널 시험체 보다 우수하다는 것을 정량적 평가하였다.