• Title/Summary/Keyword: Resistance value

Search Result 2,580, Processing Time 0.029 seconds

Thermal Properties on combination of Velvet and Lining (벨벳과 안감의 소재 조합에 따른 의복의 열저항에 관한 연구)

  • 계명대학교의류학과;이욱자;류덕환
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.1
    • /
    • pp.3-13
    • /
    • 1999
  • This study was performed for purpose of getting fundamental information requisite to wear velvet clothes that is more comfortable for the human body and also the environment. It was carried out in a human wearing test and thermal manikin test at the same time in a controlled-condition chamber. The experimental environment had a ambient temperature of 15$\pm$0.5$^{\circ}C$ with the relative humidity at 5$^{\circ}C$$\pm$5% and with air velocity at less that than 0.2m/sec. Velvet differ from common plain weaves in thermal properties because it's constructed in two parts one is ground part and the other part is pile part. In order to investigate the thermal resistance of velvet eight different combination of 4 velvet kinds and 2 lings kinds as experimental clothes. [(4 velvet kinds : Acetate cuprammoium Rayon Cotton Wool) (2 lining kinds : acetate viscose rayon)longrightarrow8 combination: Aa, Av, Ra, Rv, Ca, Cv, Wa, Wv: the simplified character] The results of this study can be summarized as follows : 1. For the regional thermal resistance the differences in eight clothes as well as differences in each part were significant. As a whole the breast part showed the highest thermal resistance and the leg part was higher than the shank part. The rank of the total thermal resistance was put at Wa>Wv>Ca>Cv>Aa>Av>Ra>Rv in this order. 2. Considered clothing microclimate microclimate temperature has a similar tendency to the total thermal resistance. It showed a significance in the differences of eight clothes and each parts. the belly part was highest in every combination. On the other hand for clothing humidity there was a significance between back and breast part only in the human wearing test. 3. It was indicated that CLO value was highly positively correlated with the clothings' weight and showed a high negative correlation with the air permeability.

  • PDF

Relative Error Analysis for Measuring Value of Ground Resistance according to Position Variation of Potential Probe) (전위보조전극의 위치변화에 따른 접지저항 측정값의 상대오차분석)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.96-102
    • /
    • 2009
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance with the fall-of-potential method are described and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error for measuring value of ground resistance due to the position of the potential probe, ground resistance were measured in case that the distance of current probe was fixed at 50[m] and the distance of potential probe was located from l0[m] to 50[m]. Also, the potential probe was located at 30[$^{\circ}$], 45[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$] and 180[$^{\circ}$]. As a consequence, relative error decreased with increasing the distance of potential probe and decreasing the angle between current probe and potential probe. The results could be help to determine the position of potential probe when the ground resistance was measured at grounding system.

Peptide Nucleic Acid Probe-Based Analysis as a New Detection Method for Clarithromycin Resistance in Helicobacter pylori

  • Jung, Da Hyun;Kim, Jie-Hyun;Jeong, Su Jin;Park, Soon Young;Kang, Il-Mo;Lee, Kyoung Hwa;Song, Young Goo
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.641-647
    • /
    • 2018
  • Background/Aims: Helicobacter pylori eradication rates are decreasing because of increases in clarithromycin resistance. Thus, finding an easy and accurate method of detecting clarithromycin resistance is important. Methods: We evaluated 70 H. pylori isolates from Korean patients. Dual-labeled peptide nucleic acid (PNA) probes were designed to detect resistance associated with point mutations in 23S ribosomal ribonucleic acid gene domain V (A2142G, A2143G, and T2182C). Data were analyzed by probe-based fluorescence melting curve analysis based on probe-target dissociation temperatures and compared with Sanger sequencing. Results: Among 70 H. pylori isolates, 0, 16, and 58 isolates contained A2142G, A2143G, and T2182C mutations, respectively. PNA probe-based analysis exhibited 100.0% positive predictive values for A2142G and A2143G and a 98.3% positive predictive value for T2182C. PNA probe-based analysis results correlated with 98.6% of Sanger sequencing results (${\kappa}$-value=0.990; standard error, 0.010). Conclusions: H. pylori clarithromycin resistance can be easily and accurately assessed by dual-labeled PNA probe-based melting curve analysis if probes are used based on the appropriate resistance-related mutations. This method is fast, simple, accurate, and adaptable for clinical samples. It may help clinicians choose a precise eradication regimen.

Insect Resistance and Horticultural Trait Genetic Values of Potato Families

  • Souza, Velci Queiroz de;Pereira, Arione da Silva;Silva, Giovani Olegario da;Carvalho, Fernando Iraja Felix de;Oliveira, Antonio Costa de
    • Journal of Crop Science and Biotechnology
    • /
    • v.11 no.1
    • /
    • pp.69-74
    • /
    • 2008
  • This work aimed to evaluate 11 potato families for insect resistance horticultural traits. The families were derived from crosses between introduced insect resistant and adapted genotypes. A randomized complete block design, with three replications was used. The plot consisted of 25 genotypes of a family, summing up to 75 genotypes tested per family. Two susceptible cultivars were included in the experiment as checks. The genotypes were evaluated for insect resistance, tuber yield traits, tuber appearance and tuber skin smoothness. The genetic value for the intensity of insect attack in the leaves and in the tubers was lower(higher resistance) in the 11 families than in the checks. For yield traits, there was no predominant effect among the families regarding the origin of the resistant donor species(Solanum berthaultii and/or S. chacoense). However, there was a large contribution of the C-1485-16-87 recurrent parent in crosses with resistant genotypes for tuber yield and tuber number. In relation to tuber appearance, only the family derived form the C-1485-16-87/ ND140(S. berthaultii) cross did not differ from the checks. had genetic value tuber skin smoothness, it was identified that families derived from S. berthaultii resistant parents showed higher genetic values than the check cultivars. For tuber skin smoothness, the genetic values of the families neither differed significantly from each other nor from the checks.

  • PDF

THE ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE OF VARIOUS DENIAL MAGNETIC ATTACHMENTS (수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구)

  • Sohn Byoung-Sup;Chang Ik-Tae;Heo Seong-Joo;Keak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.336-350
    • /
    • 2001
  • The purpose of this study was to investigate corrosion tendency and to compare corrosion resistance of three dental magnetic attachments and its keeper alloy by coercive, electrochemical method. By using petentiodynamic polarization technique, magnetic elements and its keeper alloy of Magfit EX600 system(MF, MFK), Dyna ES regular system(DN, DNK) and Shiner SR magnet system(SR, SRK) were corroded electrochemically in 0.9% NaCl electrolytic solution. Open-circuit potential and anodic polarization curve was measured with Potentiostat(model 273 EG&E) and polarization curve was created by current density per square area following scanning of increased series of voltage in the rate of 1.0mV per second. Before and after electrochemical corrosion, the surface roughness test was done. Thereafter the change of mean surface roughness value(Ra) and mean peak value(Rt) of surface roughness was compared one another. In order to observe the corroded surface of each specimen, metallurgical light microscopic(${\times}37.5$) and scanning electron microscopic view(SEM ${\times}100$) was taken and compared one another. Conclusion is followings. 1. All of six covering metal of dental magnetic attachments and its keeper alloy were corroded in various degree after electrochemical corrosion. 2. The corrosion resistance of which used in this experiment is the following in high order; DNK, MFK, DN, MF, SRK and SR. 3. Especially Shiner magnet system and its keeper alloy were more severely corroded after electrochemical corrosion and the change of Ra Rt value were more increased than others. 4 Metallurgical and scanning electron microscopic view showed the pitting corrosion tendency of all experimental alloy but DNK and SR. 5. Covering metal of magnet was more corroded than its keeper alloy.

  • PDF

Influence of Austenitizing Conditions on the Mechanical Properties in 420J1 Martensitic Stainless Steel (420J1 마르텐사이트계 스테인리스강의 오스테나이트화 조건이 기계적 성질에 미치는 영향)

  • Kim, Y.J.;Joo, D.W.;Park, S.H.;Kim, G.D.;Sung, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.7 no.1
    • /
    • pp.25-34
    • /
    • 1994
  • To investigate the effect of austenitizing tempratures on the mechanical properties and corrosion resistance of 0.19%C-13.6%Cr martensitic stainless steel, the changes in martensitic trasformation temperatures, mechanical properties and anodic polarization curve were examined after changing the austenitizing temperatures and tempering temperatures. On increasing heating rate at the same austenitizing temperatures, $A_s$, $A_r$ and $M_s$ increased. And the $M_s$ temperature showed to be decreased with increasing austenitizing temperature. With increasing tempering temperature up to $500^{\circ}C$, strength, hardness and impact value were not changed remarkably, on the other hand the tensile strength and hardness decreased and impact value increased after tempering above $550^{\circ}C$ owing to the $M_{23}C_6$ carbide precipitation. The abrupt decrease in elongation at the tempering temperture of $500^{\circ}C$ proved to the precipitation of $M_7C_3$ carbide. The effect of austenitizing temperature on the mechanical properties of the tempered specimen showed to be decreased in impact value and elongation at the austenitizing temperature of $1150^{\circ}C$. At low tempering temperatures the corrosion resistance of the tempered specimen was not changed obviously with increasing tempering temperature. On the other hand, the resistance decreased above the tempering temperature of $600^{\circ}C$ due to the precipitation of $M_{23}C_6$ carbides. The corrosion resistance showed to be improved with increasing the austenitizing temperature owing to the dissolution of carbides.

  • PDF

Analytical study of composite steel-concrete beams with external prestressing

  • Turini, Thiago T.;Calenzani, Adenilcia F.G.
    • Structural Engineering and Mechanics
    • /
    • v.82 no.5
    • /
    • pp.595-609
    • /
    • 2022
  • Prestressed composite steel-concrete beams are still a technology restricted to repair sites of large-scale structures and spans. One of the reasons for that is the absence of standard frameworks and publications regarding their design and implementation. In addition, the primary normative codes do not address this subject directly, which might be related to a scarcity of papers indicating methods of design that would align the two technics, composite beams and external prestressing. In this context, this paper proposes methods to analyze the sizing of prestressed composite beams submitted to pre-tension and post-tension with a straight or polynomial layout cable. This inquiry inspected a hundred and twenty models of prestressed composite beams according to its prestressing technology and the eccentricity and value of the prestressing force. The evaluation also included the ratio between span and height of the steel profile, thickness and typology of the concrete slab, and layout of the prestressing cables. As for the results, it was observed that the eccentricity of the prestressing force doesn't significantly influence the bending resistance. In prestressed composite beams subjected to a sagging moment, the ratio L/d can reach 35 and 30 for steel-concrete composite slabs and solid concrete slabs, respectively. Considering the negative bending moment resistance, the value of the L/d ratio must be less than or equal to 25, regardless of the type of slab. When it comes to the value of the prestressing force, a variation greater than 10% causes a 2.6% increase in the positive bending moment resistance and a 4% decrease in the negative bending moment resistance. The pre-tensioned composite beams showed a superior response to flexural-compression and excessive compression limit states than the post-tensioned ones.

Modified p-y curves to characterize the lateral behavior of helical piles

  • Hyeong-Joo, Kim;James Vincent, Reyes;Peter Rey, Dinoy;Tae-Woong, Park;Hyeong-Soo, Kim;Jun-Young, Kim
    • Geomechanics and Engineering
    • /
    • v.31 no.5
    • /
    • pp.505-518
    • /
    • 2022
  • This study introduces soil resistance multipliers at locations encompassed by the zone of influence of the helix plate to consider the added lateral resistance provided to the helical pile. The zone of influence of a helix plate is a function of its diameter and serves as a boundary condition for the modified soil resistance springs. The concept is based on implementing p-multipliers as a reduction factor for piles in group action. The application of modified p-y springs in the analysis of helical piles allows for better characterization and understanding of the lateral behavior of helical piles, which will help further the development of design methods. To execute the proposed method, a finite difference program, HPCap (Helical Pile Capacity), was developed by the authors using Matlab. The program computes the deflection, shear force, bending moment, and soil resistance of the helical pile and allows the user to freely input the value of the zone of influence and Ω (a coefficient that affects the value of the p-multiplier). Results from ten full-scale lateral load tests on helical piles embedded at depths of 3.0 m with varying shaft diameters, shaft thicknesses, and helix configurations were analyzed to determine the zone of influence and the magnitude of the p-multipliers. The analysis determined that the value of the p-multipliers is influenced by the ratio between the pile embedment length and the shaft diameter (Dp), the effective helix diameter (Dh-Dp), and the zone of influence. Furthermore, the zone of influence is recommended to be 1.75 times the helix diameter (Dh). Using the numerical analysis method presented in this study, the predicted deflections of the various helical pile cases showed good agreement with the observed field test results.

Strategy to Overcome Drug Resistance That Develops during Treatment of Chronic Hepatitis B in Children

  • Hong, Suk Jin;Choe, Byung-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.15 no.2
    • /
    • pp.63-73
    • /
    • 2012
  • Development of antiviral resistance to lamivudine is the most important factor for the treatment failure. It is necessary to establish proper guidelines to overcome drug resistance for children with chronic hepatitis B. Primary treatment with lamivudine should be considered if patients are in immune-clearance phase and have persistently elevated ALT levels more than twice the upper limit of normal value. Before initiating the therapy, careful consideration of the patient's status is required to exclude abnormal liver function tests due to other causes. The treatment option should be carefully decided to suppress the viral replication effectively. To obtain good compliance, clinicians should educate patients and their parents. Appropriate monitoring for virologic breakthrough and genotypic resistance is important in deciding to change the treatment plan. Sequential monotherapy should be avoided and a combination of drugs in other categories is recommended. New antiviral agents, such as entecavir and tenofovir, which have high potency and high genetic barrier, are soon expected to be available for use with children.

Multiscale Characteristics of Electrical Contact Resistance (전기접촉저항의 멀티스케일 특징)

  • Lee, Chang-Wook;Jang, Yong-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.404-409
    • /
    • 2004
  • The electrical contact resistance is here estimated using the multiscale microcontact distribution of elastic contact between rough surfaces, simulated from the Archard's model, and the electrical contact conduction theory suggested by Greenwood. These analysis confirms that the electrical contact resistance is converged to a values, larger than would be obtained if the contact spots were widely separated and hence independent. In multiscale process, the base potential is close to the value of the potential difference between the contact surface and the extremity of body, suggesting a possibility to obtain the multiscale electrical contact resistance relations.

  • PDF