• 제목/요약/키워드: Resistance to root penetration

검색결과 31건 처리시간 0.02초

생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구 (A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge)

  • 선윤숙;최수영;김명지;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구 (A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System)

  • 이정훈;선윤숙;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구 (A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs)

  • 오상근;곽규성;선윤숙;권시원
    • 한국건축시공학회지
    • /
    • 제7권1호
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구 (A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System)

  • 조일규;권시원;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

옥상녹화 방수 및 방근 기술로서 동판재의 적합성 및 시공성에 관한 연구 (A Study on the Workability and Application of Cooper Plate based on the Waterproofing and Root Penetration Resistance)

  • 박창화;조일규;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.151-154
    • /
    • 2007
  • To build up the green roofs, it must not adverse effect to durability and structural safety. That is conducted by safety system which consist of waterproofing to form basically, root barrier to protect the waterproofing. The reason why root barrier form is to protect the penetration force of root growth and the root could penetrate concrete surface, move inward so far. It may cause shorten the life span on concrete structure. For this problem, government constantly demand the solution to form the root barrier for waterproofing and concrete structure before the building is service. However, the technical action is not fully prepared. Therefore, in this study, we would like to suggest the workability and suitability of the copper plate to solve not only the side of waterproofing but also root barrier for green roof system and exhibit the mechanism for root penetration resistance and corrosion resistance.

  • PDF

인공녹화 기반 콘크리트 구조체의 안전성 확보를 위한 옥상녹화 방수층의 내근성 평가 (Test for Root Penetration Resistance for Waterproofing Layer proper to assure Structural Safety on the Concrete)

  • 권시원;선윤숙;곽규성;오상근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.873-876
    • /
    • 2006
  • At the green roof on the concrete structure, root penetration can be the most problem to water leakage. Root occur cracks due to penetrate to concrete which have porous organization by itself. Crack on the concrete structure would be constantly shrinks and expands, it occur to water leakage and decrease durability of concrete structure. Therefore, in this paper, the result of the root penetration test for waterproofing which protect concrete structure from the water leakage or other environment conditions would be apply to understand the reason of root penetration.

  • PDF

국내외 옥상녹화 기술현황분석을 통한 국내 방수.방근기술의 개선방향연구 (Direction to Develop Domestic Technology for Waterproofing and Root Penetration Resistance in Comparative Study of Overseas Technology on Green Roof System)

  • 권시원;배기선;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.13-17
    • /
    • 2007
  • The green roof industry have been developed with Europe, North America, Japan. At the same time, being recognized the important of green roofs in domestic industry and we just start to develop the relative technology as analyzing the future direction of advanced technology. Recently, local self-government including Seoul support the system for green roof which provide 50% of working expenses form of Matching Fund by Seed Money. As years go by, the number of build up the green roof has gradually increased to be proved. At this result caused by management of system in government, unstructured construction system, low development of support technology. In this study as analyzing the present of technical development, supporting by law and system for the advanced waterproofing and root penetration resistance technology, we suggest the development direction of it to be compared with application advanced technology and we could strengthen the international competitiveness to be industrialized the green roof considering system, technology, human infrastructure.

  • PDF

자주식 심토환경 개선기 개발(1) - 과수원의 토양 다짐 특성 및 심토 관리 실태 - (Development of Self-propelled Explosive Subsoiler (1) - Present Status of Soil Compaction and Subsoil Management in Orchard -)

  • 이동훈;박우풍;이규승
    • Journal of Biosystems Engineering
    • /
    • 제34권6호
    • /
    • pp.397-403
    • /
    • 2009
  • This study was carried out to investigate the present status of subsoil compaction, and subsoil compaction management in orchard as a basic study for developing a self-propelled explosive subsoiler. Subsoil compaction was evaluated using the soil penetration resistance. Soil cone index was measured using the DIK 5520 type cone penetrometer in several fruit farms such as apple, pear, peach and grapes during growing seasons of these fruit in Jecheon, Gamgok, Choongju, Cheonan and Hwasung areas. Most of the subsoil managing machinery were either explosive type or digging type attached to the tractor or power tiller and turning radius of this machine was more than 3-5 m. Many of the farmers wanted to use the subsoiler which can put lime into soil and rupture soil at the same time. For most of the orchard fields, soil penetration resistance in vehicle traffic area was increased quickly and reached about 1.0 MPa in 5 cm soil depth. As the soil depth increased to 15-20 cm, cone penetration resistance reached about 2.0-2.5 MPa which restricted root growth seriously. Thus it was concluded that one of the main reason for increasing the soil compaction in orchard fields is agricultural vehicle traffic. In the vicinity of fruit trees, compaction is not so serious compared to that of the vehicle traffic area, but as the soil depth increased to 20-25 cm, in most of the orchard fields soil penetration resistance reached about 2.0-2.5 MPa which is the root growth-limiting value. Considering the rooting depth of fruit trees which ranged 30-60 cm for apple, pear and peach, and 20-30 cm for grape, it is necessary to loosen the subosoil and improve the subsoil conditions using subsoiler.

Biological and Structural Mechanisms of Disease Development and Resistance in Chili Pepper Infected with the Root-knot Nematode

  • Moon, Hyo-Sun;Khan, Zakaullah;Kim, Sang-Gyu;Son, Seon-Hye;Kim, Young-Ho
    • The Plant Pathology Journal
    • /
    • 제26권2호
    • /
    • pp.149-153
    • /
    • 2010
  • Biological and structural mechanisms of the nematode disease development in chili pepper caused by the root-knot nematode, Meloidogyne incognita, were investigated. Out of 39 chili pepper cultivars/lines tested, six were found resistant, while 33 were susceptible to M. incognita, of which a susceptible cultivar Chilseongcho and three resistant cultivar/lines CM334, 02G132 and 03G53 with different resistance degrees were selected for microscopic studies on the disease development. Gall formation was greatly reduced in the resistant cultivars/lines. Nematode penetration occurred both in the susceptible and resistant chili pepper roots; however, the penetration rates were significantly lowered in the three resistant peppers compared to the susceptible pepper cv. Chilseongcho. In the susceptible pepper, giant cells were extensively formed with no discernible necrosis around the nematode feeding sites. In the highly resistant pepper cultivar CM334, no giant cell was formed, but extensive necrosis formation was observed around the penetrating nematodes. In the other two resistant pepper lines (02G132 and 03G53), both giant cells and prominent necroses were formed, and the necrotic responses appeared to inhibit the further development of giant cells or accelerate their early degeneration. Although the nematode penetration was retarded significantly in the resistant cultivar/lines, all of the above results suggest that the disease resistance of pepper may be related to post-infectional defense mechanisms (nematode growth and development) more than pre-infectional ones (penetration and establishment). Variations in structural modifications in the resistant cultivar/lines may reflect their genetic differences related to the nematode resistance.

인공지반 녹화용 방수방근 복합공법의 시공환경을 고려한 성능평가 시스템 연구 (Performance Evaluation System for Construction Environment of the Unified Waterproofing-Root Resistance Membrane layer of the Green Roof System)

  • 박창화;오상근;임남기
    • 한국건축시공학회지
    • /
    • 제11권2호
    • /
    • pp.189-199
    • /
    • 2011
  • 도심지 환경 개선을 위한 인공지반녹화(옥상녹화 등)사업의 확대 보급을 위해서는 옥상부 구조체의 장기적 안정성을 보증할 수 있는 안전한 방수방근층을 구성하여야한다. 따라서 인공지반 녹화용 방수방근층은 식물 뿌리의 침입으로부터 안전해야 하며, 녹화부의 잔류수 및 침체수 등에 대해 장기적으로 수밀해야 하며, 식물 성장에 필요한 비료 등의 화학물질 및 기타의 화학성분에 장기적으로 안전해야 하며, 시공 시에 발생하는 각종 공구류, 설비류, 가설물에 의해 손상되지 않아야 하고, 식재 및 토심의 하중, 설비류의 하중에 의해 손상되지 않는 종합적 성능이 요구된다. 이에 본 연구에서는 옥상녹화 현장의 환경 조건을 대상으로 방수방근층의 환경 성능 지표를 설정하였고, 이와 관련한 방근성능, 수밀성능, 내움패임 저항성능, 충격저항성능, 내화학성능을 방수방근층의 요구 성능으로 정하였으며, 그와 관련한 평가 방법을 제시하고, 실무적인 검증 시험을 통하여 복합 방수방근층의 성능 평가 시스템을 제안하였다.