• Title/Summary/Keyword: Resistance Method

Search Result 6,883, Processing Time 0.034 seconds

A Research on the Added Resistance Due to Weather at Sea (해상에서의 기상상태에 기인된 부가저항에 관한 고찰)

  • ;Townsin, R. L.
    • Journal of Ocean Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.56-61
    • /
    • 1993
  • Standard values in graphic porms are presented for the ratio of added wave resistance to the sun of added wave and wind resistances in head sea for three ship types, tanker, container ship and passenger ship. The effect of ship length on the ratio defined above is investigated for the three ship types. Obique sea added resistance is determined using wave direction reduction factor. The factor is obtained from model test results and cubic spline interpolation technique.

  • PDF

Fire Performance of 100MPa High Strength Concrete with Fire Protection Cover (100MPa급 내화피복 고강도 콘크리트의 내화성능 인증)

  • Song, Young-Chan;Kim, Yong-Ro;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05b
    • /
    • pp.21-22
    • /
    • 2010
  • In this research, the purpose is to share fire resistance method to secure 3 hours fire resistance performance which is regulation noticed by Ministry of Land, Transport and Maritime Affairs for 100MPa high strength concrete which is predicted to apply to high rise building and to propose the guideline for confirmation of fire resistance performance of high strength concrete member to which fire resistance method is applied and field application in advance.

  • PDF

On-line Identification of Rotor Resistance for Sensorless Induction Motors Using Variable Rotor Flux (가변 회전자 자속 지령에 의한 센서리스 유도전동기의 회전자 저항 실시간 동정)

  • Lee Zhen-Guo;Jeong Seok-Kwon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.101-109
    • /
    • 2005
  • The newly developed speed sensorless control scheme is proposed to estimate both motor speed and rotor resistance simultaneously using variable rotor flux. The rotor flux is given as sinusoidal waveform with an amplitude and a frequency without affecting precise torque control. Especially the proposed method makes the simultaneous estimation of rotor resistance and speed with high precision even though at the low speed area including a few rpm. Moreover, on-line identification of rotor resistance can be performed simply without calculating troublesome trigonometric functions and complicated integral computation. Therefore, the proposed system can be accomplished by using very cheap microprocessors for several applications. The results of the numerical simulations and experiments demonstrate that this method is effective to estimate the speed and on-line identification of rotor resistance for sensorless induction motors.

Simultaneous Estimation of Rotor Speed and Rotor Resistance of an Induction Motor Using Variable Rotor Flux

  • Lee Zhen-Guo;Jeong Seok-Kwon
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.282-288
    • /
    • 2005
  • In this paper, a new speed sensorless induction motor scheme which can estimate rotor speed and rotor resistance simultaneously is presented. The rotor flux with a low frequency sinusoidal waveform is used to conduct on-line simultaneous estimation of the rotor speed and rotor resistance. Hence the proposed sensorless control method is robust to rotor resistance variations. Also, the control scheme has no current minor loop to determine voltage references. It contributes to good control performance at low speeds. Some simulation results supported by experiments are given to show the effectiveness of this method.

Influence of Joint on Retrofitting Effect by Exterior Steel Frames of Existing RC Buildings (외부접합공법의 내진보강효과에 미치는 접합부의 영향)

  • Ahn, Choong Weon;Min, Chan Gi;Noh, Eun Choul;Han, Hong Soo;Kim, Tae Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.183-194
    • /
    • 2015
  • In this paper, Nonlinear Static Pushover analysis method(NSP) is proposed which apply to RC buildings reinforced by external retrofit for seismic performance. Based on previous analysis and research, NSP is more developed by connection nonlinearity according to shear resistance mechanism such as dowel and adhesive resistance as major shear resistance elements. According to the proposed method, structural analysis for example buildings was carried out to evaluate seismic performance of buildings. And, it was confirmed that depending on shear strain and characteristics of joint resistant of external retrofitting are different from internal retrofitting. Furthermore, the strength reduction coefficient of the anchor needs to be considered at the joint design.

Characteristics of Field Uplift Tests of Continuous Greenhouse using the Load Control Method (하중 제어법을 이용한 파이프 줄기초의 현장 인발저항 특성)

  • Lim, Seong-Yoon;Kim, Myeong-Hwan;Kim, Yu-Yong;Yu, Seok-Chul;Kim, Seok-Jin;Lim, Jae-Sam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.4
    • /
    • pp.105-111
    • /
    • 2018
  • Institutional inertia anti-disaster standard was presented mainly on the upper surface, it is necessary to improve to the soil type standard and uplift the resistance standard greenhouse that are vulnerable to strong winds. In this study, we carried out a field test using the load control method in order to evaluate the uplift resistance of continuous foundation of greenhouse with different depths of the rafters. Institutional inertia anti-disaster standard of greenhouse foundation did not protect the greenhouse structure from the damages caused by strong winds and heavy snow. Therefore, field tests for behavior characteristics of continuous greenhouse foundation were carried out to ensure stable facility cultivation. The field test condition was evaluated using different embedded depth as follows: 30cm, 40cm, 50cm and spacing 50cm, 60cm, 70 cm. As a result of the uplift resistance field tests using the load control method, the minimum uplift resistance was found to be over 90kg and uplift resistance displacement was 9.4mm. Uplift resistance of the continuous greenhouse foundation was in the range of 90-180 kg according to embedded depth and spacing. Using the test condition, there was no constant trend in the uplift resistance.

The 4-channel Multiple Contact Resistance Measurement Systems using MQTT Broker Server for AC 22.9 kV COS/Lightning Arrester (MQTT 브로커 서버를 이용한 AC 22.9 kV 차단기/피뢰기의 4-채널 다중 접촉저항 측정 시스템)

  • Ra-Yun Boo;Jung-Hun Choi;Myung-Eui Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.2
    • /
    • pp.203-208
    • /
    • 2023
  • In this study, we propose a method to improve the precision of contact resistance measurement circuits using constant current method and voltage drop method, and implement a dashboard that monitors the measured data of contact resistance measurement systems through MQTT broker server. The contact resistance measurement system measures the resistance value and transmits the measured value to the MQTT broker server using wireless communications. This developed dashboard uses Node-RED and Node-RED-Dashboard to receive the resistance values of up to four contact resistance measurement systems and show them to user's monitor screen. Users can manage multiple measurement data using a single dashboard and easily interface with other devices through the MQTT broker server. Through the experimental results from real data measurements, the relative standard deviation about precision is improved to average 40.37% and maximum 64.73% respectively.

Combustibility of Cellulose Insulation Treated with Boric acid-Borax-Aluminium sulfate Formulation (붕산-붕사-Aluminium sulfate 계 셀룰로오스 단열재의 연소특성 연구)

  • Kim, Hong;In, Se-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.4
    • /
    • pp.7-12
    • /
    • 1992
  • The smouldering combustibility of cellulose insulation treated with boric acid-borax-aluminium sulfate as combustion retardants are examined by cigarette ignition method and electrical cardrige heater method. The effectiveness of Aluminium sulfate as a third combustion are acceptable both smouldering resistance and flame resistance at 18% level of all examined formulation. As the proportion of Aluminium sulfate in the formulation was increased, the flame resistance of cellulose insulation was improved.

  • PDF

Extension of Guilloton's Method for the Calculation of Wave-making Resistance and Velocities at the Vicinity of a Ship Hull(2nd Report)

  • D.K.,Lee
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.24 no.1
    • /
    • pp.17-28
    • /
    • 1987
  • The materials to develop a computer-based method for the wave resistance of a ship within the frame of Guilloton's wedge concept are presented in this paper. A systematic reliable procedure to retrieve the linearized hull corresponding to a given real hull form(the so-called inverse transformation) has been devised. The algorithm based on the present materials produces evidently accurate values of the H-functions, and the wave profiles and the wave resistance coefficients in good agreement with the experimental measurements.

  • PDF

Value Analysis of Floor Covering Methods Considering the Skid Resistance Performance (미끄럼저항성능을 고려한 바닥재 시공법의 성능평가방안)

  • Yoon, Cha-Woong;Seol, Jae-Nam;Seo, Jong-Won
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.2
    • /
    • pp.58-69
    • /
    • 2012
  • In modern society, rooftops and underground spaces are utilized for overcoming a confined space limitation of metropolitan areas. Therefore, floor covering construction is also increasing steadily. From the user's viewpoint, skid resistance performance of floor covering methods is a very important performance criterion for safety and amenity, but an appropriate design and assessment criteria for skid resistance performance are not available. This study presents the skid resistance performance assessment method of floor covering methods considering the sidewalk skid resistance standard of Seoul city and the guideline of the Ministry of Land, Transport and Maritime Affairs(MLTM) of Korea for road safety facilities'installation and maintenance. For this research, three alternatives among urethane floor covering methods are selected and their skid resistance performance is analyzed through an experimental study. The analyzed performance is also evaluated by the skid resistance performance assessment method. Finally, the comprehensive performance assessment including the results of skid resistance performance assessment is conducted by Value Analysis(VA) in order to encourage the construction methods of floor covering which have a high skid resistance performance. As a result of VA, the particle method which the skid resistance performance is improved up to four times more than other alternatives shows the highest performance index of 83.86.