• Title/Summary/Keyword: Residuals treatment

Search Result 38, Processing Time 0.02 seconds

A study on the treatment of water discharge from the water treatment plant using end-free submerged membrane - Causes and solution of membrane fouling - (자유 말단형 침지식 분리막을 이용한 정수장 배출수 처리 연구 - 막오염 발생 원인과 해결 방안 -)

  • Kim, Jun-Hyun;Jang, Jung-Woo;Kim, Jin-Ho;Park, Kwang-Duck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.2
    • /
    • pp.93-104
    • /
    • 2020
  • As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling. were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.

Piggery Waste Treatment using Improved MLE Process in Full-Scale (수정된 MLE 공정을 이용한 Full-Scale에서의 돈사분뇨처리)

  • Hwang, In-Su;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.895-904
    • /
    • 2006
  • The improved MLE (modified Ludzack-Ettinger) process was operated for piggery waste treatment in full-scale public livestock waste treatment plant. The treated waste from bioreactor was suitable for the strict effluent standard of 200 mgCOD/L and 60 mgTN/L as it was dewatered chemically without settling tank and passed through filtration process. Though this treatment method produced a great deal of sludge ($6.4m^3\;per\;m^3$ dewatered piggery waste) it was able to accomplish predominant effluent quality by removing non-biodegradable COD and color without advanced oxidation process as ozone, fenton and etc.. The nitrogen removal efficiency of bioreactor was rapidly declined from March to May (from 0.016 to 0.005 kgN/kgVSS-day) when disinfection is in earnest as well as from warm season when reactor temperature rises higher than $35^{\circ}C$(from 0.016 to 0.008 kgN/kgVSS-day). This study proves that counterplanes for infection residuals, bioreactor temperature and dewatering sludge reduction are necessary for piggery waste treatment.

Design of Residual Treatment Process with Filter Backwash Recycle System (역세척수 회수시스템이 포함된 배출수처리공정의 설계)

  • Bae, Byung-Uk;Choi, Kyung-Hwan
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.1
    • /
    • pp.109-114
    • /
    • 2012
  • In this study, both sedimentation and thickening experiments were conducted for residuals produced from an advanced water treatment plant for more accurate and practical design of residual treatment train. In order to design a backwashed residual sedimentation basin (SRSB) in the filter backwash water recycle system, two kinds of backwash waters, one from sand filter (SFBW) and the other from GAC adsorption bed (GACBW), were separately collected and their surface loading rate measured. In addition, in order to design a gravity thickener, batch thickening tests were conducted for concentrated residuals taken from sedimentation basin and their limiting solid flux ($SF_{L}$) measured. From the experimental results and consideration of the seasonal characteristics of the residual, surface loading rate of $70m^{3}/m^{2}{\cdot}d$ was proposed as a design parameter for SRSB and solid loading rate of 20 kg $TS/m^{2}{\cdot}d$ was proposed as a design parameter for gravity thickeners. Finally, the material mass-balance was made for the design of each unit process in the residual treatment train.

Heterotrophic Bacteria in Terms of Free Chlorine Residuals in water Distribution Systems (수돗물 배급수 계통의 유리잔류염소농도에 따른 종속영양세균의 거동에 관한 연구)

  • Yoon, Tae-Ho;Lee, Yoon-Jin;Rhee, Ok-Jae;Lee, Euk-Wang;Kim, Hyun;Lee, Dong-Chan;Nam, Sang-Ho
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.3
    • /
    • pp.9-18
    • /
    • 2002
  • This study was to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution systems belong to both K and Y water treatment plant. The data analyzed in this study showed that in distribution systems(DS), the free chlorine residuals were decreased from 0.10 to 0.56 ㎎/1 for K, and 0.51 and 0.78 ㎎/l for Y The decay of free chlorine were clearly higher in both March and August than those in January. The HPC in DS were ranged from 0 to 40 CFU/ml for K,0 to 270 CFU/ml for Y, on R2A medium. In particular, Its level was relatively high at consumers' ground storage tanks, taps and point-of-end area of Y, The predominant genera found in the distribution systems were Acinetobacter, Sphingomonas (branch of Pseudomonas), Microroccus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria was increased in the end-point area. Most of them were either encapsulated cells or cocci of gram-positve. In conclusion, the point-of-end area in distribution systems showed that the longer flow distance from WTP the greater diversity and higher level of heterotrophic bacteria due to the significant decay of free chlorine residuals.

Thickening Characteristics of Residual from a Ceramic Membrane Water Treatment Plant (세라믹 막 정수공정에서 발생하는 배출수의 농축특성)

  • Bae, Byung-Uk;Shen, Xing-Hai
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.764-767
    • /
    • 2009
  • For a more effectively designed gravity thickener, thickening experiments were conducted for residuals produced by a ceramic membrane water treatment plant (WTP). Two kinds of residuals, one from backwashing (BW) and the other from chemically enhanced backwashing (CEB) procedure, were separately collected during a pilot plant experiment and their limiting solid flux ($SF_L$) measured. Batch thickening experiments showed that the BW and CEB residual had $SF_L$ of 10 and $25kg/m^2{\cdot}d$, respectively. Continuous operation of a pilot-scale gravity thickener proved that a mixed BW and CEB residual could be successfully thickened at the solid loading rate (SLR) of $12kg/m^2{\cdot}d$, allowing the concentration of the thickened residual to be about $15kg/m^2{\cdot}d$. From the experimental results and consideration of the seasonal thickening characteristics of the residual, SLR of $15kg/m^2{\cdot}d$ was proposed as a design parameter for full-scale gravity thickeners.

Effects of Massage Therapy on Feeding Intolerance and Physical Growth in Premature Infants (마사지요법이 미숙아의 수유불내성과 신체성장에 미치는 효과)

  • Seo, Hyun Young;Kim, Young Hae;Kim, Sung-Ju
    • Child Health Nursing Research
    • /
    • v.22 no.4
    • /
    • pp.355-362
    • /
    • 2016
  • Purpose: The purpose of this study was to identify effects of Massage therapy on feeding intolerance and physical growth in premature infants. Methods: This study was conducted in the NICU of U university hospital, from June to December 2014. A quasi experimental design was used. A total of 60 premature infants were randomly assigned into two groups of 30 infants each. Infants of control group were given conventional treatment, while infants of experimental group given conventional treatment plus massage therapy. Massage therapy was performed for 15 minutes, 60 min before feeding, 3 times per day for 21 times over 7 days. The number of feedings withheld for feeding intolerance, number of gastric residuals, number of fecal excretions and physical growth variables (weight, height) were measured. Results: After the intervention, number of fecal excretions and weight gain in the experimental group were significantly higher than that of the control group. Also, number of gastric residuals in the experimental group was lower than that of the control group. Conclusion: Massage therapy laid the basis for nursing intervention to promote feeding tolerance and physical growth in premature infants.

Effects of High Pressure Treatment on Cured Colour Development and Residual Nitrite Level in Model System

  • Hong, Geun-Pyo;Park, Sung-Hee;Kim, Jee-Yeon;Ko, Se-Hee;Lee, Sung;Min, Sang-Gi
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2006.05a
    • /
    • pp.325-328
    • /
    • 2006
  • In low nitrite level, treatment of combined with pressure and thermal processing improved cured meat colour comparing with that of only thermal processing. However, visual colour of only pressurised treatment could not be improved at low nitrite level. Pressure treatment could develop cured meat colour when high nitrite level was added. Moreover, pressurisation combined with thermal processing decreased nitrite residuals compared to thermal processing. Therefore the results indicated that pressurisation combined with thermal processing had potential benefits in appearance of cured meat products, promising improved food safety.

  • PDF

Influence of mixed liquor suspended solids on the removal efficiency of a hybrid membrane bioreactor

  • Palmarin, Matthew J.;Young, Stephanie
    • Membrane and Water Treatment
    • /
    • v.7 no.1
    • /
    • pp.11-22
    • /
    • 2016
  • The characterization of treatment performance with respect to mixed liquor suspended solids (MLSS) concentration enables greater control over system performance and contaminant removal efficiency. Hybrid membrane bioreactors (HMBRs) have yet to be well characterized in this regard, particularly in the context of greywater treatment. The aim of this study, therefore, was to determine the optimal MLSS concentration for a decentralized HMBR greywater reclamation system under typical loading conditions. Treatment performance was measured at MLSS concentrations ranging from 1000 to 4000 mg/L. The treated effluent was characterized in terms of biochemical oxygen demand ($BOD_5$), chemical oxygen demand (COD), turbidity, ammonia ($NH_3$), total phosphorus (TP), total kjeldahl nitrogen (TKN), and total nitrogen (TN). An MLSS concentration ranging from 3000 to 4000 mg/L yielded optimal results, with $BOD_5$, COD, turbidity, $NH_3$, TP, TKN, and TN removals reaching 99.2%, 97.8%, 99.8%, 99.9%, 97.9%, 95.1%, and 44.8%, respectively. The corresponding food-to-microorganism ratio during these trials was approximately 0.23 to 0.28. Operation at an MLSS concentration of 1000 mg/L resulted in an irrecoverable loss of floc, and contaminant residuals exceeded typical guideline values for reuse in non-potable water applications. Therefore, it is suggested that operation at or below this threshold be avoided.