• 제목/요약/키워드: Residual tensile strength

검색결과 266건 처리시간 0.026초

침탄질화 처리된 크롬-몰리브덴(SCM415)강의 피로거동 및 응력해석 -피로강도에 영향을 주는 제 인자를 중심으로 - (A Study on Stress Analysis and Fatigue Behaviors of Carbonitried Cr-Mo(SCM415) Steel -About Various Factors Having an Effect on Fatigue Strength-)

  • 송삼홍;이상훈
    • 한국정밀공학회지
    • /
    • 제15권8호
    • /
    • pp.135-144
    • /
    • 1998
  • In this research, the fatigue behaviors of Cr-Mo(SCM415) steel and carbonitrided CrMo(SCM415) steel are examined. The description of experiments in detail as follows. For SCM415 and carbonitried Cr-Mo(SCM415) steel, smooth specimens and hole defected specimens are fabricated and tested under a rotary bending tester, respectively. By performing the rotary bending fatigue test for smooth and hole defected specimens, the characteristics of the fatigue strength are examined for parameters such as tensile strength, hardness at surface, and residual stresses.

  • PDF

COLD CRACK SUSCEPTIBILITY OF HIGH STRENGTH WELD METAL

  • Kim, H. J.;B. Y. Kang
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.266-272
    • /
    • 2002
  • This study reviews the factors controlling the weld metal cracking and shows the difference from those of HAZ cracking. It further reviews the recent progresses made in consumable design for improving the crack resistance in the high strength weld metal. Previously the controlling factors for weld metal cracking were regarded as weld metal strength, diffusible hydrogen and weld metal height. However an overall review presented in this article shows that the cold crack resistance can be improve significantly through the microstructural control and that an increase in tensile strength is not necessarily related to a decrease in the resistance to cold cracking.

  • PDF

건축구조용 냉간성형 강관의 가공성능 평가 (Evaluation of Forming Performance of Cold Rolled Steel Pipes & Tubes for Building Structure)

  • 임성우;최광;장인화
    • 한국강구조학회 논문집
    • /
    • 제16권1호통권68호
    • /
    • pp.33-42
    • /
    • 2004
  • SN 강재를 건축구조용으로 사용하기 위해서는 설계기준강도가 제정되어야 한다. 선행 연구로써, SN400B/490B 후판재로 재판한 SN400B/490B 원형강관과 SPAP235/325 및 SPAR295 각형강관의 물성을 평가하였다. SN400B/490B 후판재와 비교했을 때 STKN400B/490B 원형강관의 항복인장 및 인장강도는 상승하였지만, 제조 프로세스에 무관하게 STKN400B/490B 원형강관의 규격을 만족 하였다. 그러나 SPAP235/325 각형강관 모서리부에서의 항복인장 및 인장강도는 규격을 벗어났다. 이것은 SPAP235/325 각형강관 규격에서 정하고 있는 값이 모서리부에서의 값이 아니라 변에서의 값이기 때문이다. STKN490B 원형강관에 발생한 최대 인장잔류응력은 모재 항복강도 수준이며, 최대 압축잔류응력은 모재 항복강도의 40% 수준이었다. 또한 SPAP325 각형강관에 발생한 최대 인장잔류응력과 최대 압축잔류응력은 모두 모재 항복강도의 80% 수준이었다. 중심압축실험을 한 결과 STKN490B 원형강관의 좌굴강도는 제조 프로세스에 관계없이 별 차이를 보이지 않았다. 그러나 각형강관의 경우는 SPAP325 각형강관이 SN490B로 built-up한 각형강관보다 좌굴강도가 높게 나타났다.

집성재 라미나용 낙엽송 재내 잔류 건조응력 변화 분석 (Analysis of residual drying stress in Larix Kaempferi wood used as glulam laminar)

  • 한연중;장윤성;박용건;정기영;홍정표;이전제;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권6호
    • /
    • pp.535-543
    • /
    • 2013
  • 본 연구에서 국산 낙엽송재의 공학목재로의 이용가능성, 특히 교호집성재 라미나로서의 이용가능성을 확인하기 위하여 열기건조 중과 건조 후 판재 내 잔류응력을 분석하였다. 연구결과를 통해 이쿼라이징 처리에 의한 함수율 동일화 효과가 증명되었고, 컨디셔닝 처리에 의한 잔류응력의 감소효과가 정량화되었다. 건조 중 목재 내 잔류응력 분석을 위하여 프롱법과 슬라이스법을 실시하였다. 프롱 제작 후 표면경화율을 측정하였고, 슬라이스의 절단 후 탄성변형량을 기준으로 표면으로부터 약 10 mm 깊이까지의 건조응력을 정량적으로 분석하였다. T10-C4와 T12-D5 열기건조 스케줄 적용 시 열기건조 중 판재 표면의 인장응력과 압축응력은 모두 2.2 MPa을 넘지 않음을 확인하였다. 낙엽송의 횡단방향 인장강도와 압축강도가 평균 2.65 MPa, 4.60 MPa인 점을 고려하면, 더욱 강한 건조스케줄 적용이 추천된다. 건조 후처리에 의해 폭굽음과 비틀림을 약 40% 줄일 수 있었다.

Effect of steel fiber volume fraction and aspect ratio type on the mechanical properties of SIFCON-based HPFRCC

  • Kim, Seugnwon;Jung, Haekook;Kim, Yongjae;Park, Cheolwoo
    • Structural Engineering and Mechanics
    • /
    • 제65권2호
    • /
    • pp.163-171
    • /
    • 2018
  • Plain concrete is a brittle material with a very low tensile strength compared to compressive strength and critical tensile strain. This study analyzed the dynamic characteristics of high-performance fiber-reinforced cementitious composites based on slurry-infiltrated fiber concrete (SIFCON-based HPFRCC), which maximizes the steel-fiber volume fraction and uses high-strength mortar to increase resistance to loads, such as explosion and impact, with a very short acting time. For major experimental variables, three levels of fiber aspect ratio and five levels of fiber volume fraction between 6.0% and 8.0% were considered, and the flexural strength and toughness characteristics were analyzed according to these variables. Furthermore, three levels of the aspect ratio of used steel fibers were considered. The highest flexural strength of 65.0 MPa was shown at the fiber aspect ratio of 80 and the fiber volume fraction of 7.0%, and the flexural strength and toughness increased proportionally to the fiber volume fraction. The test results according to fiber aspect ratio and fiber volume fraction revealed that after the initial crack, the load of the SIFCON-based HPFRCC continuously increased because of the high fiber volume fraction. In addition, sufficient residual strength was achieved after the maximum strength; this achievement will bring about positive effects on the brittle fracture of structures when an unexpected load, such as explosion or impact, is applied.

Evaluating the Protective Effectiveness of Rubber Glove Materials Against Organic Solvents Upon Repeated Exposure and Decontamination

  • Li-Wen Liu;Cheng-Ping Chang;Yu-Wen Lin;Wei-Ming Chu
    • Safety and Health at Work
    • /
    • 제15권2호
    • /
    • pp.228-235
    • /
    • 2024
  • Background: Glove reuse poses risks, as chemicals can persist even after cleaning. Decontamination methods like thermal aeration, recommended by US OSHA, vary in effectiveness. Some studies show promising results, while others emphasize the importance of considering both permeation and tensile strength changes. This research advocates for informed glove reuse, emphasizing optimal thermal aeration temperatures and providing evidence to guide users in maintaining protection efficiency. Methods: The investigation evaluated Neoprene and Nitrile gloves (22 mils). Permeation tests with toluene and acetone adhered to American Society for Testing Materials (ASTM) F739 standards. Decontamination optimization involved aeration at various temperatures. The experiment proceeded with a maximum of 22 re-exposure cycles. Tensile strength and elongation were assessed following ASTM D 412 protocols. Breakthrough time differences were statistically analyzed using t-test and ANOVA. Results: At room temperature, glove residuals decreased, and standardized breakthrough time (SBT)2 was significantly lower than SBT1, indicating reduced protection. Higher temperature decontamination accelerated residual removal, with ∆SBT (SBT2/SBT1) exceeding 100%, signifying restored protection. Tensile tests showed stable neoprene properties postdecontamination. Results underscore thermal aeration's efficacy for gloves reuse, emphasizing temperature's pivotal role. Findings recommend meticulous management strategies, especially post-breakthrough, to uphold glove-protective performance. Conclusions: Thermal aeration at 100℃ for 1 hour proves effective, restoring protection without compromising glove strength. The study, covering twenty cycles, suggests safe glove reuse with proper decontamination, reducing costs significantly. However, limitations in chemical-glove combinations and exclusive focus on specific gloves caution against broad generalization. The absence of regulatory directives on glove reuse highlight the importance of informed selection and rigorous decontamination validation for workplace safety practices.

Comparison of macrosynthetic and steel FRC shear-critical beams with similar residual flexure tensile strengths

  • Ortiz-Navas, Francisco;Navarro-Gregori, Juan;Leiva, Gabriel;Serna, Pedro
    • Structural Engineering and Mechanics
    • /
    • 제76권4호
    • /
    • pp.491-503
    • /
    • 2020
  • This study extends previous experimental research on the shear behaviour of macrosynthetic fibre-reinforced concrete beams and compares them to steel fibre-reinforced concrete beams with similar mechanical and geometrical properties. This work employed two fibre types: 60/0.9 (long/diameter) double hooked-end steel fibre and 60/85 monofilament polypropylene fibre. Beams were tested by shear loading covering parameters, such as two different cross-section widths, two shear-span-to-effective-depth ratios, two fibre types and using repetitions with and without transverse reinforcement. For quantitative comparison purposes, crack pattern evolution was studied along increasing loads levels. Effects were studied by photogrammetry, including influence of fibres on crack propagation in uncracked and dowel zones, influence of fibres on stirrup behaviour, and shear deformation or kinematics of critical shear cracks. The results evidenced similar effectiveness for both fibre types in controlling shear crack propagation and horizontal dowel cracking. Both fibres provided similar shear ductility and shear deflections. Consequently, the authors confirm that residual flexural tensile strengths are a convenient parameter for characterising the shear behaviour of fibre-reinforced concrete beams.

ETFE 막재에 대한 인장실험과 크리프 실험 (Tensile Test and Creep Tests of ETFE Membrane)

  • 김재열;강주원
    • 한국공간구조학회논문집
    • /
    • 제10권3호
    • /
    • pp.57-64
    • /
    • 2010
  • 본 논문에서는 세 종류의 ETFE 막재에 대한 단축인장실험을 수행하였다. 이 실험에서 얻은 변형도-변위 곡선을 분석함으로써 항복응력, 두 번째 항복응력, 탄성계수, 두 번째 탄성계수, 그리고 세 번째 탄성계수를 얻게 되었다. 아울러, 탄성 단계와 항복 단계, 소성유동 단계에서 각각 ETFE 막재의 사이클 하중시험을 진행하여, 잔여변형률, 응력 이완, 하중 변화(재하/제하) 중 ETFE 막재의 탄성 변화 등을 알아본다. 재료의 크리프시험에서는 25, 40, 60$^{\circ}C$의 시험온도와 3, 6, 9MPa의 인장 응력 하에서 크리프시험의 시간은 24시간으로 설정하였다.

  • PDF

Generalization of shear truss model to the case of SFRC beams with stirrups

  • Colajanni, Piero;Recupero, Antonino;Spinella, Nino
    • Computers and Concrete
    • /
    • 제9권3호
    • /
    • pp.227-244
    • /
    • 2012
  • A theoretical model for shear strength evaluation of fibrous concrete beams reinforced with stirrups is proposed. The formulation is founded on the theory of plasticity and the stress field concepts, generalizing a known plastic model for calculating the bearing capacity of reinforced concrete beams, to the case of fibrous concrete. The beneficial effect of steel fibres is estimated taking into account the residual tensile strength of fibrous concrete, by modifying an analytical constitutive law which presents a plastic plateau as a post-peak branch. Around fifty results of experimental tests carried out on steel fibrous concrete beams available in the literature were collected, and a comparison of shear strength estimation provided by other semi-empirical models is performed, proving that the numerical values obtained with the proposed model are in very good agreement with the experimental results.

화재피해 콘크리트의 수열온도에 따른 강도 및 색상 변화 연구 (A Study on the Variation of Strength and Color According to Heated Temperatures of Fire­Damaged Concrete)

  • 최광호
    • 한국건설순환자원학회논문집
    • /
    • 제8권3호
    • /
    • pp.325-332
    • /
    • 2020
  • 화재피해 콘크리트 구조물의 안전진단 시, 기존 내구성 평가 방법으로는 고온으로 인한 강도감소 및 재료의 변화 등을 정량화하기가 어렵다. 특히, 두께별 손상도가 다른 공시체의 압축강도를 부재의 압축강도 저하의 대표 값으로 사용하고 있어 콘크리트의 깊이에 따른 손상도 변화를 반영하지 못하고 있다. 이 연구에서는 고온에 노출된 콘크리트의 손상깊이를 정량적으로 평가하기 위하여 400℃-800℃ 온도로 콘크리트 공시체를 전면 가열과 일면 가열 조건으로 가열실험을 수행하였다. 가열 후 전면 가열 공시체의 압축실험과, 일면 가열 공시체를 고온 노출면부터 20mm두께의 절편을 만든 후 각각에 대해 쪼갬 인장실험과 색조분석을 실시하였다. 실험결과, 공시체 절편의 쪼갬 인장강도로부터 산정된 압축강도 감소율이 전면 가열공시체의 압축강도 값과 평균 10% 이내로 나타났고, 색조분석 결과 400℃-600℃에서 빨강 색상, 700℃이상에서는 회색계열로 변색되는 일관적인 색상 값이 관찰된 바, 이 연구에서 제안한 기법은 수열온도의 추정과 콘크리트 잔존 압축강도와 손상깊이를 합리적으로 평가할 수 있는 것으로 나타났다.