• Title/Summary/Keyword: Residual current

Search Result 738, Processing Time 0.029 seconds

Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가)

  • Cho, Han-Goo;Yun, Han-Soo;Kim, Seok-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.

Development of ZnO Varistor for Distribution Surge Arrester (18kV, 5kA) (배전급 피뢰기(18kV, 5kA)용 ZnO 바리스터 소자 개발)

  • 박춘현;윤관준;조이곤;정세영;서형권
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.212-216
    • /
    • 2000
  • ZnO varistors for distribution surge arrester (18kV, 5kA) were developed and tested microstructure and electrical characteristics. Microstructure of ZnO varistor was consisted of ZnO grain, spinel phase and Bi-rich phase. Average grain size of ZnO varistor was $\mu\textrm{m}$ Reference voltage and lightning impulse residual voltage of ZnO varistor exhibited a good haracteristics above 5.5kV and below 11.56kV, respectively. Consequently, discharge capacity which is the most important characteristics of ZnO varistor for surge arrester exhibited excellent properties above 70kA at twice high-current impulse test. Moreover, variation rate of reference voltage and lightning impulse residual voltage showed below 5% and 2% after high-current impulse test, respectively. Leakage current and watt loss of ZnO varistor will not increase during accelerated aging test at stress condition, such as 3.213kV/$115^{\circ}C$/1000h.

  • PDF

Long Duration Current Impulse Withstand Characteristics and Uniformity of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량과 균일성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, You-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.486-487
    • /
    • 2007
  • This paper describes the evaluation of long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and three abroad varistors were also prepared to be compared. All varistors exhibited high density, which was in the range of $5.42{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage of all samples was in the range of 5.11~5.72kV and the residual voltage was in the range of 8.314~9.305kV. In the long duration current impulse withstand test, sample 2 and 3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived were below 1.7%, which were in the acceptance range of 5%.

  • PDF

Effect of the Co$^{60}$ -Rays due to Electric properties of EPR- (EPR의 전기특성에 미치는 방사선의 영향)

  • 이성일
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.11a
    • /
    • pp.253-259
    • /
    • 2002
  • The value of charge currnet, discharge current, ${\varepsilon}r^'$,${\varepsilon}r^{'}$ residual voltage was measured inorder to investigate electric properties in Ethylene Prophylene Rubber for is irradiated C0$^{60}$$\gamma$ ray 0~38.1 Mrad. The value of charge current and the discharging current of the EPR is influenced by C0$^{60}$-$\gamma$- irradiation dose. The charging current and the discharging current of EPR increas, depending on the ratio of degradation. As the irradiatin dose is increased, the peak of residual voltage moves to the slorter time. The properties specific electric constant due to time variation was appeared dispersion by plentiful C0$^{60}$$\gamma$- irradiation dose. The increase of peak in ${\varepsilon}r^{'}$ is attrib uted to the irratiation dose almost proportionally.

  • PDF

A study of sedimentation processes in Seamangeum coastal area (새만금지구의 퇴적과정에 관한 연구)

  • Sin Mun-Seop;Yu Cheol-Ung;Kim Ik-Jung
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.73-76
    • /
    • 1997
  • The purpose of this study is to find sedimentation patterns variation in Saemangeum coastal sea region. Water circulations are calculated diagnostically from the observed water temperature and salinity data and wind data and tidal residual current. Three dimensional movements of injected particles due In currents, turbulence and sinking velocity are tracked by the Euler-lagrange method. Calculated sedimentation patterns of riverine material are highly similar to the observed ones.

  • PDF

Change of Electrical Characteristics of ZnO Arrester Blocks by Lightning Impulse Current (뇌충격전류에 의한 산화아연형 피뢰기 소자의 전기적 특성변화)

  • Gil, Gyeong-Seok;Han, Ju-Seop;Park, Yeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.7
    • /
    • pp.550-555
    • /
    • 1999
  • This paper deals with the effect of lightning impulse current on electrical characteristics of ZnO blocks used in distribution lightning arrester. The electrical characteristics of ZnO blocks are degraded by overtime impulse current, and the degraded ZnO block is brought to a thermal runaway and finally destroyed. It is therefore important to estimate the change of electrical characteristics of ZnO blocks. In this study, an impulse current generator which can produce 8/20$[\mus]$, 3[㎄] and 4/10$[\mus]$, 5[㎄] waveform is designed and fabricated to simulate the lightning impulse current of power systems. Total energy applied to the ZnO blocks at each time is 739[J] in 8/20$[\mus]$, and 523[J] in 4/10$[\mus]$, impulse current, respectively. From the experimental results, the 3rd harmonic of the leakage current increases continuously with the number of applied impulse current, but no significant changes in residual voltage and in reference voltage are observed until the ZnO block is destroyed. Also, it is confirmed that the main factor on degradation of ZnO blocks is rather the total energy applied to ZnO blocks than the peak value of the impulse current.

  • PDF

Effects of Electrodeposition Conditions on Properties of Ni Thin Films Electrodeposited from Baths Fabricated by Dissolving Metal Ni Powders (금속 Ni 분말을 용해한 도금용액으로부터 전기도금 된 Ni 박막 특성에 미치는 도금조건의 영향)

  • Yoon, Pilgeun;Park, Keun-Yong;Uhm, Young Rang;Choi, Sun Ju;Park, Deok-Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.48 no.3
    • /
    • pp.73-81
    • /
    • 2015
  • Chloride plating solution was fabricated by dissolving metal Ni powders in solution with HCl and deionized water. Effects of deposition conditions on the properties of Ni films electrodeposited from chloride baths were studied. Current efficiency of Ni films electrodeposited from the baths containing saccharin was decreased with increasing the current density. Residual stress of Ni thin films ware measured to be about 230 ~ 435 MPa in the range of current density of $10{\sim}25mA/cm^2$. Cathode current efficiency in baths without saccharin was initially increased with increasing pH, while it was decreased with increasing pH further. Cathode current efficiency in baths with saccharin (except at pH 2) exhibited less 10 ~ 20% than that in baths without saccharin. Residual stress of Ni films electrodeposited from baths without saccharin was measured to be 388 ~ 473 MPa in the range of pH 2 ~ pH 5 and then was increased to 551 MPa at pH 6. On the other hand, residual stress of Ni films electrodeposited from baths with saccharin was increased with increasing pH. Surface morphology was strongly affected by the change of current density, but slightly by solution pH and addition of saccharin.

Estimation of Tidal Residual Flow and Its Variability in Kyunggi Bay of Korea (경기만 조석 잔차류 산정 및 변동성)

  • Kim, Chang-S.;Lim, H.S.;Kim, Jin-Ah;Kim, Seon-Jeong;Park, K.S.;Jung, K.T.
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.6
    • /
    • pp.353-360
    • /
    • 2010
  • The Kyunggi Bay in mid-west of Korea is a relatively large estuarine system that connects the Han River system with Yellow Sea. Due to macro-tidal range of more than 8 m, the urban estuary shows deep tidal channels and wide tidal flats. Since last 30 years, the coastal development is undergoing, yielding noticeable change in environment. Particularly the tidal flat dynamics are generally accepted as being related with tidal residual flows in this area (Kim et al., 2009). We have estimated the annual variation and vertical structure of residual currents with one-year long observed flows in two major tidal channels of Kyunggi Bay. The moving average method and tidal current harmonic analysis yield nearly the same results on residual flow. The residual flow in Jangbong channel ranges from 20 cm/s in summer to 30 cm/s in winter. It is noticeable that the residual flow in Jangbong channel is flood dominant throughout the year, while the flow in Seokmo channel is ebb-dominant residual flow with current speed range of 20-40 cm/s. Due to the baroclinic response of relatively shallow estuary, significant reduction of energy in bottom layers have been observed, indicating the importance of residual circulation to the tidal flat behavior.

Heat Source Modeling and Study on the Effect of Thickness on Residual Stress Distribution in Electron Beam Welding

  • Rajabi, Leila;Ghoreishi, Majid
    • Journal of Welding and Joining
    • /
    • v.35 no.1
    • /
    • pp.49-54
    • /
    • 2017
  • In this study, the volumetric heat source in electron beam welding (EBW) is modeled through finite element method taking advantage of ABAQUS software package. Since this welding method is being applied in plates with different thicknesses and also considering that residual stresses reduce the strength of these weldments, the effect of thickness in the distribution and magnitude of residual stresses after welding is studied. Regarding the vast application of Inconel 706 super-alloy in aerospace industries, this material was selected in the current research. In order to validate the finite element model, the obtained results were compared to those of other researchers in this area, and good agreement was observed. The simulation results revealed that increase in the plate thickness leads to increase in the residual stresses. In addition heat treatment in the base metal (before welding) increases the residual stresses significantly.

Predicting Method of Rosidual Stress Using Artificial Neural Network In $CO_2$ Are Weldling (인공신경망을 이용한 탄산가스 아크용접의 잔류응력 예측)

  • 조용준;이세현;엄기원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.482-487
    • /
    • 1993
  • A prediction method for determining the welding residual stress by artificial neural network is proposed. A three-dimensional transient thermomechanical analysis has been performed for the CO $_{2}$ Arc Welding using the finite element method. The validity of the above results is demonstrated by experimental elastic stress relief method which is called Holl Drilling Method. The first part of numarical analysis performs a three-dimensional transient heat transfer anslysis, and the second part then uses results of the first part and performs a three-dimensional transient thermo-clasto-plastic analysis to compute transient and residual stresses in the weld. Data from the finite element method were used to train a backpropagation neural network to predict residual stress. Architecturally, the finite element method were used to train a backpropagation voltage and the current, a hidden layer to accommodate failure mechanism mapping, and an output layer for residual stress. The trained network was then applied to the prediction of residual stress in the four specimens. The results of predicted residual stress have been very encouraging.

  • PDF