• Title/Summary/Keyword: Residual change

Search Result 753, Processing Time 0.023 seconds

The Effects of Multiple Recycling on Deinkability and Properties of Recycled Paper

  • Shin, Jun-Seop;Cho, Hern-Joung
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04b
    • /
    • pp.361-365
    • /
    • 1999
  • This study examined the effects of multiple recycling on deinkability and properties of recycled paper from laser computer printout (LCPO). First, alkaline paper with a 20% printed area was disintegrated by TAPPI standard disintegrator at room temperature. After dewatering, the pulp was flotated and dried in oven at80$^{\circ}C$ for 24 hrs. A sequence of wetting, disintegrating, flotating and drying was one recycling cycle and this cyclic treatment was repeated from zero to five times. The recycled handsheet dropped to 90% of the original brightness after five cycles, and lost the most brightness after five cycles, and lost the most brightness in the first two cycles. However, it had a gain of 10% in opacity after five cycles as the same as the case of nonprinting. And, in this study, the method for determining residual ink(toner) content in recycled handsheets ere established by means of SEM-EDX and Py-GC. The change of residual ink percentage on recycled paper showed the effect of recycling numbers on deinkability of waste paper. A slight decrease in deinkability was noted for the recycled handsheets, which may be due to the change of fiber surface free energy connected with fiber swelling.

짝비교 기법을 활용한 보조지하수관측망 위치선정 기준 수립에 관한 연구

  • 김정우;김규법;원종호;이진용;이명재;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.259-262
    • /
    • 2003
  • In the Republic of Korea, Ministry of Construction & Transportation and Korea Water Resources Corporation manage the national groundwater monitoring network at the 169 stations and will organize the supplementary groundwater monitoring network at the 10,000 stations by 2011 year. The method that organizes the monitoring network was developed using the Analytic Hierarchy Process with pairwise comparison. Several estimation factors for the estimating every district were selected to reflect each district conditions. Their weighting value was decided by pairwise comparison and questions to the experts about groundwater The optimal number of groundwater monitoring well was calculated through the developed method. To verify this method, groundwater was monitored in Jeonju city by way showing the example. The study area In Jeonju city needs 7 stations for the supplementary groundwater monitoring network. The results monitored in 7 stations inferred the groundwater level around the study area by Kriging. The mean of residual between inferred groundwater level value from Kriging and actual groundwater level is rather low. Furthermore, the mean and standard deviation of residual between inferred groundwater level change and actual groundwater change is much lower. The Fact that 7 monitoring stations are sufficient for observing the groundwater condition in the study area makes it possible for suggested monitoring number to be proper.

  • PDF

Numerical Assessment for Coastal Water Purification Utilizing a Tidal Jet System (조석분류를 이용한 연안해역의 수질정화에 관한 수치적 평가)

  • Park, Jong-Chun
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.4 s.71
    • /
    • pp.58-63
    • /
    • 2006
  • When the costal zone surrounded by a breakwater has a narrow vertical opening, currents in the vicinity of a narrow entrance can result in a jet flow, coinciding with the tide. Such a Tidal-Jet Generator(TJG) can change the water mass distribution and transport processes in the domain of influence of the jet. Also, it can decrease the residual time of them. In the present study, the water purification utilizing tidal jets in the coastal zone over constant bathymetry are estimated numerically, using a finite-difference numerical scheme, named the NS-MAC-TIDE method, which isbased on the fully 3D Navier-stokes(NS) equations. The shear velocity near the inlet of the TJG are predicted from the flow field simulation, and are assessed qualitatively with the development of scouring or sediment that is caused by the change of diffusion or sweeping flowup from the seabed of sediment particles. Finally, through solving a transport equation of concentration, the residual time related on mass transport processes and the flushing mechanism for water purification are investigated.

A Study of Transient Estuarine Circulation in the Chunsu Bay, Yellow Sea: Impact of Freshwater Discharge by Artificial Dikes

  • Jeong, Kwang-Young;Ro, Young Jae;Kang, Tae Soon;Choi, Yang Ho;Kim, Changsin;Kim, Baek Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.3
    • /
    • pp.242-253
    • /
    • 2020
  • This study examined the ef ects of freshwater discharge by artificial dikes from the Kanwol and Bunam lakes on the dynamics in the Chunsu Bay, Yellow Sea, Korea, during the summer season based on three-dimensional numerical modeling experiments. Model performances were evaluated in terms of skill scores for tidal elevation, velocity, temperature, and salinity and these scores mostly exceeded 90 %. The variability in residual currents before and after the freshwater discharge was examined. The large amount of lake water discharge through artificial dikes may result in a dramatically changed density field in the Chunsu Bay, leading to an estuarine circulation system. The density-driven current formed as a result of the freshwater inflow through the artificial dikes (Kanwol/Bunam) caused a partial change in the tidal circulation and a change in the scale and location of paired residual eddies. The stratification formed by strengthened static stability following the freshwater discharge led to a dramatic increase in the Richardson number and lasted for a few weeks. The strong stratification suppressed the vertical flux and inhibited surface aerated water mixing with bottom water. This phenomenon would have direct and indirect impacts on the marine environment such as hypoxia/anoxia formation at the bottom.

A radiographic evaluation of graft height changes after maxillary sinus augmentation

  • Kim, Do-Hyung;Ko, Min-Jeong;Lee, Jae-Hong;Jeong, Seoung-Nyum
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.3
    • /
    • pp.174-181
    • /
    • 2018
  • Purpose: The aims of the present study were to quantitatively assess graft height changes after sinus lift procedures and to analyze the factors that influenced graft height changes, including the residual bone height before surgery, surgical approach, and tooth type. Methods: A total of 39 maxillary posterior implants placed during a simultaneous sinus lift procedure were evaluated. Panoramic radiographs of all patients were taken immediately after implant installation and at 3 months, 6 months, 1 year, 2 years, and 3 years. To analyze graft height changes over time, we measured the distance between the implant platform and the base of the grafted sinus floor at 3 locations. The radiographs were analyzed by a single examiner. Results: Graft height tended to decrease over time, and a statistically significant difference was observed at 2 years compared to baseline (P<0.05). There was no statistically significant difference in graft height change according to the surgical approach or tooth type. For residual bone height, a statistically significant difference in graft height change was found between those with 4-7 mm of residual bone height and those with ${\geq}7mm$ (P<0.05). Conclusions: Graft height after sinus lift procedures significantly decreased at 2 years compared to baseline after sinus augmentation. Further studies should be done with controlled variables, and prospective studies with 3-dimensional images are needed to clarify the factors that influence graft height changes.

Changes of Recycled Paper Properties and Waste Paper Deinkability by the Repeated Recycling of Photocopy Paper (복사용지의 리사이클링 반복처리에 따른 재생지의 특성 및 고지의 탈묵성 변화)

  • Shin, Jun-Seop
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.4 no.2
    • /
    • pp.24-32
    • /
    • 1998
  • This study examined the effects of recycling on chemical pulp fibers from multiple recycles. Firstly, water-pretreated alkaline photocopy paper was disintegrated by TAPPI standard disintegrator at room temperature. After dewatering, this pulp was dried in oven at $80^{\circ}C$ for 24hrs. A sequence of wetting, disintegrating and drying was one recycling cycle and this cyclic treatment was repeated from zero to five times. The recycled handsheet dropped to 90% of the original brightness after five cycles, and lost the most brightness in the first two cycles. However, it had a gain of 10% in opacity after five cycles. And, in this study, the method for determining residual ink(toner) content in recycled handsheets were estabilished by means of SEM-EDX and atomic absorptive photometer. The change of residual ink percentage on recycled paper showed the effect of recycling numbers on deinkability of waste paper. A slight decrease in deinkability was noted for the recycled handsheets, which may be due to the change of fiber surface free energy connected with fiber swelling.

  • PDF

Oxolinic acid Residue in the cultured Eel Tissues and its Change to Heating Process (시판중인 뱀장어중의 Oxolinic acid 잔류량과 가열에 의한 변화)

  • 김경호;송미란;최선남;최민순;박관하
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.1
    • /
    • pp.14-19
    • /
    • 1998
  • The residual tissue concentraion of the widely used aquatic antibacterial agent, oxolinic acid, was surveyed in eels collected from fish markets of Chonbuk Province, Korea. Their concentrations in the dorsolateral muscle were widely varying. In about 32% of samples examined, oxolinic acid was not detected. In about 16% of those samples in which oxolinic acid was detected, the concentration was above 0.1 ppm. The tissue distrubution of the agent in major organs was in the rank order of kidney>liver>plasma>muscle. When the muscle samples which contained residual oxolinic acid were baked for up to 10 min, there was no change in the drug concentration. Their concentration declined to about 50% by baking for 30 min at which time the tissue turned to the texture of charcoal. The extreme stability of oxolinic acid to heating process was confirmed with muscle samples from eels to which a high dose of oxolinic acid was administered, and also with an aqueous oxolinic acid solution of known concentration. It is suggested that an effective regulatory measure should be initiated to keep eel consumers from residual oxolinic acid impact.

  • PDF

Estimation of the Change Point in Monitoring the Mean of Autocorrelated Processes

  • Lee, Jae-Heon;Han, Jung-Hee;Jung, Sang-Hyun
    • Communications for Statistical Applications and Methods
    • /
    • v.14 no.1
    • /
    • pp.155-167
    • /
    • 2007
  • Knowing the time of the process change could lead to quicker identification of the responsible special cause and less process down time, and it could help to reduce the probability of incorrectly identifying the special cause. In this paper, we propose the maximum likelihood estimator (MLE) for the process change point when a control chart is used in monitoring the mean of a process in which the observations can be modeled as an AR(1) process plus an additional random error. The performance of the proposed MLE is compared to the performance of the built-in estimator when they are used in EWMA charts based on the residuals. The results show that the proposed MLE provides good performance in terms of both accuracy and precision of the estimator.

Influence of Organic Acids Residual Concentration by the Change of F/M Ratio on Sludge Settleability in Advanced Sewage Treatment Processes (하.폐수 고도처리시 F/M비 변화에 따른 유기산 잔류 농도가 슬러지 침강성에 미치는 영향)

  • Park, Young-Ki;Kim, Young-Il;Kim, Sl-Ki
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.42-47
    • /
    • 2006
  • The biological nutrient treatment is formed with repetition and rearrangement of anaerobic, anoxic and oxic tank. In this case, VFAs is generated in the anaerobic tank and the anoxic tank. The VFAs is an important factor for removal of nitrogen and phosphate and SVI. So, in this study I investigated to find a relationship among the generation rate of the VFAs according to the change of F/M ratio and the characteristic which can eliminate organic matter and nitrogen according to the change of residual concentration of the VFAs and the efficiency of the process and also SVI in wastewater treatment. $A^2/O$ process was used for wastewater treatment. F/M ratio was under the control of the change of MLSS concentration. When the F/M ratio was changed from 0.16 to 0.08 kg-BOD/kg-MLSS/day, the VFAs's production volume increased based on the reduction of F/M ratio in batch reaction. And the residual concentration of the VFAs decreased at first and then increased later. SVI and SS were high when F/M ratio was $0.16kg/kg{\cdot}d$ and showed stable status when F/M ratio decreased $0.11{\sim}0.13kg/kg{\cdot}d$. However, SVI and SS continuously increased with decrease of F/M ratio and were high at $0.08kg/kg{\cdot}d$. In the result of comparison between residual concentration of the VFAs and denitrification rate in anoxic tank, the less residual volume of the VFAs was in anoxic tank, the higher denitrification ratio became. The optimal residual-concentration of the VFAs considering SVI and removal efficiency of nitrogenwas $1.4{\sim}2.2mg/L$. At that time F/M ratio was $0.11{\sim}0.13$ kg-BOD/kg-MLSS/day.

The Influences of Residual Stress on the Frequency of Ultrasonic Transducers with Composite Membrane Structure

  • Lee Seungmock;Kim Jong-Min;Shin Young-Eui
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.76-84
    • /
    • 2006
  • Arrayed ultrasonic sensors based on the piezoelectric thin film (lead-zirconate-titanate: Pb($Zr_{0.52}Ti_{0.48})O_{3}$) having composite membrane structure are fabricated. Different thermal and elastic characteristics of each layer generate the residual stress during the high temperature deposition processes, accomplished diaphragm is consequently bowing. We present the membrane deflection effects originated from the residual stress on the resonant frequencies of the sensor chips. The resonant frequencies ($f_r$) measured of each sensor structures are located in the range of $87.6{\sim}111\;kHz$, these are larger $30{\sim}40\;kHz$ than the resultant frequencies of FEM. The primary factors of $f_r$ deviations from the ideal FEM results are the membrane deflections, and the influence of stiffness variations are not so large on that. Membrane deflections have the effect of total thickness increase which sensitively change the $f_r$ to the positive direction. Stress generations of the membrane are also numerically predicted for considering the effect of stiffness variations on the $f_r$.