• Title/Summary/Keyword: Residual DC

Search Result 134, Processing Time 0.038 seconds

Improvement of Photo-Alignment Characteristics for Device Applications

  • Hwang, Yong-Jae;Choi, Kil-Yeong;Yi, Mi-Hie;Hong, Sung-Hwan;Shin, Dong-Myung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.867-870
    • /
    • 2007
  • In order to solve image sticking phenomena, the gas-phase and liquid-phase interfacial reactions of photosensitive polyimide can annihilate photoreactive carbon-carbon double bonds, which remain after photo-alignment process. The annihilation processes dramatically affect residual DC and photochemical reorientation of photoactive functional groups.

  • PDF

DC Offset Adjusted Inter Prediction Algorithm for Improving H.264/AVC Video Coding Efficiency (H.264/AVC 동영상 압축율 향상을 위한 DC 오프셋 보정에 기반한 인터 예측 알고리즘)

  • Yoon, Dae-Il;Kim, Hae-Kwang
    • Journal of Broadcast Engineering
    • /
    • v.16 no.5
    • /
    • pp.793-796
    • /
    • 2011
  • H.264/AVC compresses video data by applying DCT transform, quantization and entropy coding processes to the residual signal obtained by inter/intra prediction. This paper proposes a method enhancing an existing DC offset adjustment technology which uses information of neighboring blocks to reduce residual information for improving coding efficiency. DC offset information is not sent over bitstreams, but calculated in the same way both in the decoder and in the encoder. Experimental results show that the proposed method enhances coding efficiency by 0.25% in average BD-Rate compared to H.264/AVC and gives better or worse coding efficiency compared to the existing DC offset method depending on video sequences with coding efficiency degradation by 0.09% in average BD-Rate. This experimental results also show that further coding efficiency improvement is possible by applying the proposed method adaptively to slice or macroblock coding units.

Effect of Carbon Nanotube Concentrations on Residual DC of a Twisted Nematic Liquid Crystal Cell (탄소 나노 튜브 함량에 따른 TN 액정 셀의 잔류 DC 연구)

  • Baik, In-Su;Park, Kyung-Ah;Jeon, Sang-Youn;An, Kay-Hyeok;Lee, Seung-Hee;Lee, Young-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.297-298
    • /
    • 2005
  • We have fabricated twisted nematic (TN) liquid crystal cells doped by carbon nanotubes (CNTs) with different CNT wt. %. With a minute amount doping, multi-walled CNTs did not perturb the liquid crystal orientations at the off- and on-state. The hysteresis studies of voltage-dependent capacitance (V-C) under the influence of electric field generated by ac and dc voltage show that the residual do, which is tightly related to image sticking problem in liquid crystal displays, is greatly reduced due to ion trapping by CNTs. Also, the V-C hysteresis shows dependency of capacitance on concentration of multi-walled CNTs.

  • PDF

Effects of Duty Cycle and Pulse Frequency on the Microstructure and Mechanical Properties of TiAlN Coatings (듀티 싸이클 및 펄스 주파수가 TiAlN 코팅막의 미세구조와 기계적 특성에 미치는 영향에 관한 연구)

  • Chun, Sung-Yong;Hwang, Ju Yeon
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.5
    • /
    • pp.447-452
    • /
    • 2014
  • This paper presents the effects of pulse plasma parameters such as duty cycle and pulse frequency on the properties of TiAlN coatings deposited by asymmetric bipolar pulsed DC magnetron sputtering systems. The results show that, with decreasing duty cycle and increasing pulse frequency, the coating morphology changes from a columnar structure to a dense structure with finer grains. Pulsed sputtered TiAlN coatings showed higher hardness, higher residual stress, and smaller grain sizes than did DC prepared TiAlN coatings. Moreover, residual stress and nanoindentation hardness of pulsed sputtered TiAlN coatings increased with increasing pulse frequency. Meanwhile, the surface roughness decreased continuously with increasing pulsed DC frequency up to 50 kHz.

Study on the residual DC characteristic of Twisted Nematic liquid Crystal Display on the Polyimide Surface by the Thermal Stress (폴리이미드 표면에서의 열적 스트레스에 의한 TN셀의 잔류 DC 특성 연구)

  • Bae, Yu-Han;Kim, Sang-Hoon;Hwang, Jeoung-Yeon;Kang, Hyung-Ku;Lee, Whee-Won;Kim, Jong-Hwan;Kim, Young-Hwan;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.451-452
    • /
    • 2005
  • In this study, the threshold voltage and the response time of thermal stressed TN-LCDs showed the same performances on none thermal stressed TN-LCDs. There was little change in TN cells. Also, while increasing thermal stress time, the transmittances of TN-LCDs on the rubbed PI surface were almost the same, But the thermal stability of TN cell was deteriorated.

  • PDF

Electro-optic Characteristic of Twisted Nematic Mode using a Liquid Crystal Dispersed Carbon Nanotubes (탄소 나노 튜브가 분산된 액정을 이용한 TN 모드의 전기 광학 특성 연구)

  • Baik, In-Su;Jeon, Sang-Youn;Lee, Seung-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.114-117
    • /
    • 2005
  • We have fabricated twisted nematic (TN) cell doped by carbon nanotubes (CNTs). The CNTs with a minute amount of doping do not perturb the liquid crystal orientation in the off- and on-state. The hysteresis studies of voltage-dependent transmittance and capacitance under ac and dc electric field show that the amount of residual dc, which is related to image sticking problem in liquid crystal displays, is greatly reduced due to ion trapping by CNTs.

  • PDF

Residual Insulation characteristics of long-term serviced 6.6 kV CV Cable (6.6kV 철거 CV 케이블의 잔존 절연 특성)

  • 백주흠;김동욱;한기만
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.46-49
    • /
    • 1994
  • In order to investigate possibility of CV cable diagnosis technique, residual insulation characteristics of .long - term serviced 0.6 kV CV Cable are examined by DC leakage current residual voltage tensile strength, cross1inking density and AC & impulse breakdown. Also effect of cable structure and water tree are reported

  • PDF

DC Influence Between Pixel Electrode and Alignment Layer in In-plane Switching Mode LCD

  • Lim, Young-Nam;Lee, Tae-Rim;Park, Byoung-Gyu;Roh, Seung-Kwang;Kim, Hyun-Chul;Kim, Hyun-Seung;Kim, Kyeong-Jin;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.677-680
    • /
    • 2009
  • DC influence between pixel electrode and alignment layer (AL) in in-plane switching mode LCD was analyzed through DC equivalence-circuit equation induction, DC charge-discharge simulation, luminance and residual-DC measurement systems using test patterned (TP) cell. DC discharging rate (DDR) of single layer electrode was faster than that of double layer electrode and DDR of low resistance AL was faster than that of high resistance AL. DC discharging characteristics had a close relation to layer number and resistance between two electrodes.

  • PDF

A Study on Analysis of Residual Antibiotics and Prop Acid in Honey (벌꿀중의 잔유항생물질 및 Propionic Acid 분석011 관한 조사연구)

  • 전상수
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.2
    • /
    • pp.63-80
    • /
    • 1990
  • A sensitive and simple analytical system for the simultaneous determination of residual oxytetracycline, tetracycline, and doxycycline in honey was described, and that the analytical method for determination of residual propionic acid in honey was established. Experimental subjects were purchased four kinds of honey, native kind honey, acaccia honey, mixed floral honey, chestnut honey in Kyung Sang Nam Do. Several microbiological methods are available to determine tetracycline antibiotecs(TCs) in foods but their precision apears to be variable and the specificity is questionable. These methods are considered to be not suitable for analysis of tetracycline antibiotics in honey because honey itself has bacteriostatic action. For determination of tetracycline antibiotics in honey, therefore the High Performance Liquid Chromatography(HPLC) method was applied, and the propionic acid were determined by Gas Chromatography(5.C). Ethylacetate, as an extract solvent, was found to be suitable for seperation of TCs in honey, but methanol and acetone were not. The recoverly rate of Oxytetracycline(OTC), Tetracycline(TC), Doxycycline(DC) from honey spiked at a level of 10 $\mu $g/g were 97%, 89%, and 91%, respectively. The cailbration curve in TCs was linear expression from 2$\mu $g/ml to 10$\mu $g/ml. As the results of analysis, the residual tetracycline antibiotics were not detected in the 100 samples of honey. The recovery rate of propionic acid from honey spiked at level of 10$\mu $g/g was 98.3% , and the calibra lion curves were linear expression from 21$\mu $g/ml to 101$\mu $g/ml. As the results of analysis, the residual propionic acid was not detected in the 100 samples of honey. Retention time(min) of OTC, DC, and TC were 3.35, 4.61, and 5.30 minutes at the conditions of table 2, respectively, and retention time(min) of propionic acid was 3.50 minutes at the conditions of table 3. The residual TCs and propionic acid were not detected in the 100 samples of honey, but there is a possibility that antibiotics or propionic acid will be to remain in honey if they are used during product period in order to prevent putrefaction of honey-bee.

  • PDF

A residual generator for fault detection/isolation of a class of nonlinear systems (비선형 공정의 고장검출을 위한 잔차발생알고리즘)

  • Ryu, Ji-Su;Lee, Sang-Moon;Lee, Kee-Sang;Park, Tae-Geon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2230-2232
    • /
    • 2004
  • A residual generation scheme that can be employed in the process fault detection and isolation systems for a class of nonlinear (control) systems is suggested. Although the scheme is a kind of observer scheme, the design of the observers employed for residual generation is very simple and the order of the observer is very low. In spite of the simplicity, the residual generation scheme provides the same information for the detection and isolation of the anticipated faults as the conventional multiple observer based schemes. The residuals may be structured so that fault isolation can be performed by pre-selected logic. An FDIS using the residual generation scheme is constructed and evaluated for a nonlinear DC motor system.

  • PDF