• Title/Summary/Keyword: Residential Environments

Search Result 294, Processing Time 0.02 seconds

The Occupant Perception and Investigation of Indoor Air Quality at Home in Seoul

  • Sohn, Jong-Ryeul;Kim, Young-Whan;Byeon, Sang-Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.51-57
    • /
    • 2003
  • Indoor air quality(IAQ) in workplace and residential environments has been concern of people. Recently, Ministry of Environment in Korea has recognized the potential risk on the healthy effect related to indoor air pollution at home. Therefore, the purpose of this study was performed to measure the indoor air pollutants of IAQ at different homes and investigate to compare the perception of IAQ recognition at home from questionnaire survey in Seoul. We estimated the IAQ of selected 6 homes based on site region and housing type. The indoor air pollutants and parameters such as temperature, relative humidity, respirable suspended particulate matter($PM_{10}$), formaldehyde(HCHO), total bacteria counts, carbon monooxide(CO) and carbon dioxide($CO_2$) were monitored for summer and winter. In monitoring results, the respirable suspended particulate matter(($PM_{10}$) and indoor airborne bacteria level of home 5 and 6 were higher than the standard of the public $150{\;}{\mu}g/m^3$ and $500{\;}{\mu}g/m^3$, the level formaldehyde(HCHO) was exceed 0.1 ppm of the standard of Korea at all monitored homes. In statistics analysis, we could find a correlation between the building age and the concentration of CO, TBC were significant at 0.01 level and Relative Humidity was significant at 0.05 level for summer. Finally, the important air pollutants of IAQ in home were HCHO and total bacteria counts(TBC). And we performed a questionnaire survey of 500 people about their awareness for the importance of IAQ in our home during same period. In results, all most response of occupant has recognized the importance of IAQ at home. Therefore, it can be concluded that the IAQ of selected 6 home studied was perceived as acceptable, it is recommended that the government related IAQ was suggested the guideline and control of IAQ problems, and the occupants need to be effort to reduce the exposure of sources to undesirable pollutants.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

The Needs of Housing Contents in Highschool Home Economics among Students (고등학생의 '가정과학' 주생활 단원 내용 요구도)

  • Kim, Lan;Cho, Jea-Soon
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.3
    • /
    • pp.145-161
    • /
    • 2008
  • The purpose of this paper is to find out the needs of housing contents in highschool Home Economics among students. The 105 housing contents and topics were chosen from the 3 textbooks and related references. The number of 516 questionnaire from 8 areas were used to analyze. Analyses indicated that respondents were more likely to favor Home Economics subject and one out of five wanted to select it. Average needs of the housing contents was above middle(3.4) and these was a little difference among 3 middle units in housing. The most needed unit was housing design. There was a more wide difference in 19 small units than in middle ones, ranged $3.00\sim3.91$. Individual contents showed the most variousness in needs from 2.89 to 4.30 in the middle unit of housing and environments, 3.00 to 4.01 in housing design, and 2.68 to 3.91 in housing management. The needs of additional contents were about the same as those textbook contents and it indicated that new textbook needs to adopt the newly demanded housing contents. Some of individual, family, and environmental characteristics were significantly related to the students needs. The higher positive attitude such as favor, interest, and selecting of the subject was related to the higher needs of housing contents. Residential areas and neighboring were also related to most of the needs of individual housing contents.

  • PDF

Evaluation of Space-based Wetland InSAR Observations with ALOS-2 ScanSAR Mode (습지대 변화 관측을 위한 ALOS-2 광대역 모드 적용 연구)

  • Hong, Sang-Hoon;Wdowinski, Shimon
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.447-460
    • /
    • 2022
  • It is well known that satellite synthetic aperture radar interferometry (InSAR) has been widely used for the observation of surface displacement owing to earthquakes, volcanoes, and subsidence very precisely. In wetlands where vegetation exists on the surface of the water, it is possible to create a water level change map with high spatial resolution over a wide area using the InSAR technique. Currently, a number of imaging radar satellites are in operation, and most of them support a ScanSAR mode observation to gather information over a large area at once. The Cienaga Grande de Santa Marta (CGSM) wetland, located in northern Colombia, is a vast wetland developed along the Caribbean coast. The CGSM wetlands face serious environmental threats from human activities such as reclamation for agricultural uses and residential purposes as well as natural causes such as sea level rise owing to climate change. Various restoration and protection plans have been conducted to conserve these invaluable environments in recognition of the ecological importance of the CGSM wetlands. Monitoring of water level changes in wetland is very important resources to understand the hydrologic characteristics and the in-situ water level gauge stations are usually utilized to measure the water level. Although it can provide very good temporal resolution of water level information, it is limited to fully understand flow pattern owing to its very coarse spatial resolution. In this study, we evaluate the L-band ALOS-2 PALSAR-2 ScanSAR mode to observe the water level change over the wide wetland area using the radar interferometric technique. In order to assess the quality of the interferometric product in the aspect of spatial resolution and coherence, we also utilized ALOS-2 PALSAR-2 stripmap high-resolution mode observations.