• Title/Summary/Keyword: Research Facility

Search Result 4,470, Processing Time 0.041 seconds

A Study on Contribution to Reducing Chemical Accidents of Reporting for Awarding a Contract of Hazardous Chemicals (유해화학물질 도급신고 제도가 화학사고 감소에 미치는 영향 연구)

  • Kim, Sungbum;Kwak, Daehoon;Jeong, Seongkyeong;Kim, Heetae;Mun, Dahui;Oh, Jun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.3
    • /
    • pp.409-417
    • /
    • 2019
  • Purpose: Since the implementation of the Chemical Substance Management Act, data on the number of occurrences by annual chemical accident in Korea and the contractor's contract data received from the competent authority were used. After the implementation of the contract reporting system, the contribution to the reduction of chemical accidents is summarized by statistical data. The characteristics of each region, month, type and those of similar industries and human life were compared and analyzed. Method: 4 years of chemical accident statistics from 2015 to 2018 and since 2003, we have used data from the Chemical Safety Clearing-House (CSC), which provides safety information on cases of chemical accidents. Results and Conclusion: The risk of accidents increases as a number of unskilled workers are put into the workplace during the period when the hazardous chemical handling process is temporarily suspended. Through the reporting for awarding a contract, the operators are strengthening the safety management of chemical accidents by educating unskilled workers and wearing personal protective equipment.

A Study on the Relative Importance of Evaluation Factors for Improvement of Port Security (항만보안 강화를 위한 평가요인과 상대적 중요도 분석)

  • Kang, Min-Gu;Kim, Hwa-Young
    • Journal of Navigation and Port Research
    • /
    • v.43 no.1
    • /
    • pp.49-56
    • /
    • 2019
  • The purpose of this study was to extract the evaluation factors and assess the relative importance between the factors. For this purpose, the evaluation factors were extracted through literature review and the process of brainstorming with experts, who are related to port security. The evaluation factors were then classified into four higher factors and twelve sub- factors through the use of the AHP method. A survey on the classified factors was conducted by experts composed of public officials, port authority employees and education institutions officials. We also carried out statistical tests to determine the perception gap of weights between the groups. As a result of a relative importance analysis of strength, the security operating system factor was highest, followed by improvement of hardware facilities and increase of security personnel. There was a difference in perception among the groups in policy support, facility support and personnel resources budget support. The results of the analysis show that the strength operating system through the establishment of an integrated monitoring system is a priority. It is necessary to understand the difference of perception between groups and build a systematic cooperation system. The evaluation factors extracted from this study can be used for the measurement of port security efficiency in further work.

Experimental study of the air emission effect in the tangential and the multi-stage spiral inlet (접선식 유입구와 다단식 나선 유입구의 공기 배출 효과에 관한 실험적 연구)

  • Seong, Hoje;Rhee, Dong Sop;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.235-243
    • /
    • 2019
  • Recently, urban inundation was frequently occurred due to the intensive rainfall exceeding marginal capacity of the flood control facility. Furthermore, needs for the underground storage facilities to mitigate urban flood are increasing according to rapidly accelerating urbanization. Thus, in this study, drainage efficiency in drain tunnel connecting to underground storage was investigated from the air-core measurements in the drop shaft against two types of inlet structure. In case of the spiral inlet, the multi-stage structure is introduced at the bottom of the inlet to improve the vortex induction effect at low inflow discharge (multi-stage spiral inlet). The average cross-sectional area of the air-core in the multi-stage spiral inlet is 10% larger than the tangential inlet, and show the highly air emission effect and the highly inflow efficiency at the high inflow discharge. In case of the tangential inlets, the air emission effect decreased after exceeding the maximum inflow discharge, which is required to maintain the inherent performance of the tangential inlet. From the measurements, the empirical formula for the cross-sectional area of the air-core according to locations inside the drop shaft was proposed in order to provide the experimental data available for the inlet model used in experiments.

A Study on the Necessity of Vertical Garden in Public Places for Urban Environment Improvement (도시환경 개선을 위한 공공장소의 수직정원 필요성에 관한 연구)

  • Kim, Chul-soo
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.6
    • /
    • pp.75-81
    • /
    • 2021
  • (Research background and purpose) Urban development has also had a significant impact on the eco-friendly industry. In the public environment, citizens are stressed in many areas, which has really made them need a natural ecological environment. Therefore, it is necessary to improve the environment into an eco-friendly urban public facility that breathes the urban environment space inside the building with plants. To this end, we want to show that the urban environment can be improved through vertical gardens. And through this, we want to contribute to the popularization of vertical gardens. (Research Methodology) we will analyze the problems of the current public environment in the city and look at the supplementation around vertical gardens. (Result) A study of the public environment in the city found problems such as gloomy environment, poor use of space, dim color, and poor air quality, and wanted to create a vertical garden to provide a pleasant shelter. These vertical gardens have influenced urban public places with improved aesthetics, increased social value, insulation and soundproofing effects of buildings, reduced urban heat island effects, and increased urban green appearance. (Conclusion)This study uses vertical gardens in public spaces to design public spaces that are more comfortable and share mental and physical health together.

Fabrication of Fabric-based Wearable Devices with High Adhesion Properties using Electroplating Process (전해 도금을 이용한 높은 접착 특성을 갖는 섬유 기반 웨어러블 디바이스 제작)

  • Kim, Hyung Gu;Rho, Ho Kyun;Cha, Anna;Lee, Min Jung;Park, Jun-beom;Jeong, Tak;Ha, Jun-Seok
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.28 no.1
    • /
    • pp.55-60
    • /
    • 2021
  • In order to produce wearable displays with high adhesion while maintaining flexible characteristics, the adhesive method using electro plating method was carried out. Laser lift-off (LLO) transcription was also used to remove sapphire substrates from LEDs bonded to fibers. Afterwards, the SEM and EDS data of the sample, which conducted the adhesion method using electro plating, confirmed that copper actually grows through the lattice of the fiber fabric to secure the light source and fiber. The adhesion characteristics of copper were checked using Universal testing machine (UTM). After plating adhesion, the characteristics of the LLO transcription process completed and the LED without the transcription process were compared using probe station. The electroluminescence (EL) according to the enhanced current was measured to check the characteristics of the light source after the process. As the current increases, the temperature rises and the bandgap decreases, so it was confirmed that the spectrum shifted. In addition, the change in the electrical characteristics of the samples according to the radius change is confirmed using probe station. The radius strain also had mechanical strength that copper could withstand bending stress, so the Vf variation was measured below 6%. Based on these results, it is expected that it will be applied to batteries, catalysts, and solar cells that require flexibility as well as wearable displays, contributing to the development of wearable devices.

Introduction plan of future integrated water circulation management system using LID facility model verification (LID시설 모델검증을 활용한 미래형 통합 물순환관리시스템 도입방안)

  • Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.67-73
    • /
    • 2021
  • As the impermeable area increases due to urbanization and industrialization, the influence of non-point pollutants caused by rainfall runoff on the water system is increasing. In the past, the best management practices(BMP) were used a lot to manage non-point pollutants, but recently, technology that naturally treats them through LID (Low Impact Development) technology is widely used. In this study, various rainfall events were simulated through the SWMM model based on the data of rainfall monitoring in bioretention among natural facilities. The characteristic of LID modeling research is that it is difficult to build accurate modeling data with short-term data because real data is the result obtained through natural facilities, and it is difficult to implement an accurate model. In this study, the data monitored for 3 years It is significant in that it has built a precise model. The actual data monitored a total of 18 times was simulated, and the inflow and outflow and the removal efficiency of five pollutants were simulated. As a result of performing the performance evaluation, most of the 7 items showed excellent indicators, and the TN and TP showed relatively low simulation performance. In the future, it is expected that Korea will introduce an integrated water management system in which the water supply system and the sewage system are substantially integrated and operated. Therefore, the results of this study are considered to play an important role in the initial stage of rainfall management in the future integrated water management system, and the extent of rainfall runoff reduction and pollutant reduction in the expected installation area can be predicted in advance. This is expected to prevent overdesign of bioretention.

Development of IFC Standard for Securing Interoperability of BIM Data for Port Facilities (항만 BIM 데이터의 상호운용성 확보를 위한 IFC 표준 개발)

  • Moon, Hyoun-Seok;Won, Ji-Sun;Shin, Jae-Young
    • Journal of KIBIM
    • /
    • v.10 no.1
    • /
    • pp.9-22
    • /
    • 2020
  • Recently, BIM has been extended to infrastructures such as roads and bridges, and the demand for BIM standard development for ports is increasing internationally. Due to the low level of utilization of classification system and drawing standards compared to other infrastructures, and the closed nature of national security facilities, ports have insufficient level of connection and sharing environment among external systems or users. In addition, since the standardization of data for port facilities is not made, it is still necessary to establish an independent DB for each system and to ensure interoperability of data between these systems since it does not have a shared environment among similar data. Therefore, the purpose of this study is to develop and verify IFC, the international standard for BIM, in order to cope with the BIM environment and to be commonly used in the design, construction, and maintenance of port facilities. To this end, we build a standard schema with port-specific Express Notation according to buildingSMART International's standard development methodology. First, domestic and international reference model standards were analyzed to derive components such as space and facilities of port facilities. Based on this, the components of the port facility were derived through the codification, categorization, and normalization process developed by the research team. This was extended based on the port BIM object classification system developed by the research team. Normalization results were verified by designers and associations. Then, IFC schema construction was based on Express-G data modeling based on IFC 4 * 2 Candidate, which is a bridge candidate standard based on IFC4 (ISO16739), and IFC 4 * 3 Draft, which is developed by buildingSMART International. The final schema was validated using the commercialized validation tool. In addition, in order to verify the structural verification of the port IFC schema, the transformation process was verified by converting the caisson model into a Part21 file. In the future, this result will not only be used as a delivery standard for port BIM products, but will also be applied as a linkage standard between systems and a common data format for port BIM platforms when BIM is used in the maintenance phase. In particular, it is expected to be used as a core standard for data exchange in the port maintenance stage.

A Study on Residence Experiences of Elderly Living in Long-Term Care Facilities (노인요양시설 노인의 시설 거주경험에 관한 연구)

  • Cha, Sooyoun;Hur, Junsoo
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.5
    • /
    • pp.808-823
    • /
    • 2021
  • This study was conducted to explore the experience and its meaning of the elderly residents in long-term care facilities(LTCFs). It is aimed to find the role of family and society for the qualitative care of elderly living in LTCF and to seek social welfare measures. For this purpose, qualitative research data was collected by conducting in-depth interviews and participation observations on 8 elderly residents at 4 LTCFs in Seoul, Incheon, and Gyeonggi Province. The collected data were analyzed using Giorgi's phenomenological research method. The analysis results show that 33 semantic units, 14 subcomponents, and 4 upper components. The 4 upper components showed up as 「Crumbling my existence」, 「The life thrown into an unfamiliar environment」, 「New relationship where discomfort and gratitude coexist」 and 「My life I want to find」. Among them, 「My life I want to find」 was the essence of the living experiences of elderly residents in LTCF. Through this study, it was suggested creating an environment to provide facilities access preparation program for the elderly, developing and activating various family participation programs, providing conditions of Aging in place for the elderly, and developing and activating community resource linkage programs.

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

Practical Numerical Model for Wave Propagation and Fluid-Structure Interaction in Infinite Fluid (무한 유체 영역에서의 파전파 해석 및 유체-구조물 상호작용 해석을 위한 실용적 수치 모형)

  • Cho, Jeong-Rae;Han, Seong-Wook;Lee, Jin Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.6
    • /
    • pp.427-435
    • /
    • 2021
  • An analysis considering the fluid-structure interaction is required to strictly evaluate the seismic behavior of facilities such as, environmental facilities and dams, that store fluids. Specifically, in the case of an infinite domain in the upstream direction, such as a dam-reservoir system, this should be carefully considered. In this study, we proposed a practical numerical model for both wave propagation and fluid-structure interaction analyses of an infinite domain, for a system with a semi-infinite domain such as a dam-reservoir system. This method was applicable to the time domain, and enabled accurate boundary analysis. For an infinite fluid domain, a small number of mid-point integrated acoustic finite elements were applied instead of a general acoustic finite element, and a viscous boundary was imposed on the outermost boundary. The validity and accuracy of the proposed method were secured by comparing analytic solutions of a reservoir having infinite domain, with the parametric analysis results, for the number of elements and the size of the modeling region. Furthermore, the proposed method was compared with other fluid-structure interaction methods using additional mass.