• 제목/요약/키워드: Repulsive Force

검색결과 135건 처리시간 0.026초

Bi계 초전도체의 Magnetic Suspension (Magnetic Suspension Effect of BiPbSrCaCuO Superconductor)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.101-103
    • /
    • 2001
  • Suspension effect has been studied by using superconductor of BiPbSrCaCuO ceramics containing $Ag_{2}O$ It has been cleared that $Ag_{2}O$ acts as pinning center which plays an important role to the suspension effect. Magnetic repulsive force which affects a superconductor located in magnetic flux from toroidal magnet has been investigated. It has been concluded that the suspension effect arises from the interaction between the pinning effect and the diamagnetic effect.

  • PDF

자석 척력의 자전거 쿠션장치 적용 및 비선형성 고찰 (An Observation of the Application of a Magnetic Force to the Bicycle Cushion System and its Nonlinearity)

  • 윤성호
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.42-47
    • /
    • 2018
  • This paper describes the dynamical behavior of the bicycle and its nonlinear effect when magnetic repulsive forces are applied to the bicycle cushion system. A finite-element method was used to obtain its reliabilities by comparing the experimental and numerical values and select the proper magnet sizes. The Equivalent spring stiffness values were evaluated in terms of both linear and nonlinear approximations, where the nonlinear effect was specifically investigated for the ride comfort. The corresponding equations of linear and nonlinear motion were derived for the numerical model with three degrees of freedom. Dynamic behaviors were observed when the bicycle ran over a curvilinear road in the form of a sinusoidal curve. The analysis in this paper for the observed nonlinearity of magnetic repulsive forces will be a useful guide to more accurately predict the cushion design for any vehicle system.

공압식 조작기의 동작특성에 관한 해석 (Analysis on Dynamic Characteristics of Air-Pressure Type Chamber in Puffer Circuit Breaker)

  • 박상훈;배채윤;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.18-20
    • /
    • 2002
  • In this paper, various forces generated in the Gas Circuit Breaker(GCB) such as operating force, repulsive force, spring force, and dashpot force are analyzed with the fluid properties and the mechanical structure. The operation of GCB can be understood. A stroke curve from the result of simulation is compared with experimental one.

  • PDF

파우더, 첨가제의 종류와 함량에 따른 수상 내에서의 파우더 분산에 관한 연구 (A Research on Powder Dispersion Ability Using Several Content, Variety of Powder and Additive in Aqueous System)

  • 김선영;김일구;최승만;이상민
    • 대한화장품학회지
    • /
    • 제38권4호
    • /
    • pp.271-276
    • /
    • 2012
  • 본 연구에서는 파우더와 첨가제의 종류, 함량에 따른 저점도 가용화 제형에서의 파우더 분산성을 연구하였다. 파우더는 화학 구조상 부분적 극성이 존재하여 반발력이 존재하고, 물리적인 구조상 다공성 물질로 접촉 면적이 넓고 밀도가 낮은 PMMA 파우더가 뛰어난 분산성을 보였다. 파우더가 분산되어 있는 견본에 염을 첨가한 견본의 경우 염이 첨가되지 않은 견본에 비해 우수한 분산성을 보여주었다. 이때의 분산성은 염의 농도에 의존적인 성향을 보이며, 같은 농도에서 1가 이온으로 이루어진 NaCl, KCl에 비해 2가 이온으로 이루어진 $MgSO_4$에서 더 높은 분산능을 보였다. 이는 염이 이온화되어 파우더의 주변에 존재하여 파우더간의 반발력을 높여주기 때문에 응집 현상이 줄어들고 분산능을 증가시키는 것으로 해석할 수 있다. 마지막으로 MgSO4 염이 첨가되어 있는 견본에 EDTA를 첨가제로 첨가하면 그렇지 않은 견본에 비해 더욱 뛰어난 분산능을 보여 주었다. EDTA는 금속 양이온과 결합하여 그 작용을 막으므로, EDTA가 포함된 견본은 음이온에 의한 작용이 극대화되어 파우더간의 반발력이 더욱 커지게 된다. 이는 결국 파우더의 수분산성을 향상시키고 제형의 안정화에 도움을 줄 수 있다.

의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가 (A Haptic Master-slave Robot System : Experimental Performance Evaluation for Medical Application)

  • 오종석;신원기;프엉박;엄창호;최승복
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.41-48
    • /
    • 2013
  • In this work, 4-DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery(MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4-DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가 (A Haptic Master-Slave Robot System : Experimental Performance Evaluation for Medical Application)

  • 오종석;신원기;프엉박;엄창호;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.421-427
    • /
    • 2012
  • In this work, 4 DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery (MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4 DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

  • PDF

(알니코, 사마리움-코발트) 본드자석의 제조 및 자기적 특성연구 (Fabrication of the (Alnico, Sm-Co) Bonded Magnet and its Magnetic Properties)

  • 김정식
    • 한국전기전자재료학회논문지
    • /
    • 제23권12호
    • /
    • pp.988-995
    • /
    • 2010
  • In this study the (Alnico, Sm-Co) bonded magnets were fabricated by mixing the Sm-Co added alnico alloy powders with epoxy resin and binder, appropriately. Also, the hybrid ring magnets of (Alnico, Sm-Co)/Sr-ferrite were fabricated by coupling the Sr-ferrite composite layer with an (Alnico, Sm-Co) magnet. The magnetic properties of (Alnico, Sm-Co) ring magnets were varied with the amount of Sm-Co powders. The addition of Sm-Co powders increased a remanent induction($B_r$) and coercive force($_BH_C$), while decreasing a surface flux density and repulsive distance. The surface flux density and repulsive distance for the (Alnico, Sm-Co) ring magnet increased with a magnetizing voltage up to about 160 V and reached an apparent saturation point. Also, the measurements of temperature and moisture characteristics showed that the surface flux densities of N-S poles and repulsive distance decreased a little within 4% after 10 days passed.

스트레인게이지가 부착된 충격력 측정 장비 개발 (Development of an Impact Force Measurement Device with an Attached Strain Gauge)

  • 정익수
    • 한국운동역학회지
    • /
    • 제22권2호
    • /
    • pp.243-251
    • /
    • 2012
  • The purpose of this study was to develop an impact force measurement device in order to facilitate the acquisition of quantitative data for the analysis of various sporting events. The device was designed to include cylindrical aluminum supports of 220 mm diameter, which allows mounting and dismounting of the device on walls and frames. In addition, a hard sponge for impact absorption, as well as 4 springs, were attached to the plate. Both were attached to prevent psychological variables and injuries. When a subject applies force on the device, accurate data about the maximum repulsive force is acquired in real time, with a lag of only 0.001 s. The device was calibrated in four steps: (1) increase, (2) increase, (3) increase-decrease, and (4) increase-decrease. The maximum relative expanded uncertainty was 0.166%, indicating that the impact force measurement was sufficiently reliable. The proposed device can be applied to various sporting situations and is expected to be useful for studying kinetics.

대장내시경을 위한 자기 충격 액츄에이터 (Magnetic Impact Actuator for Robotic Endoscope)

  • 민현진;임형준;김병규;김수현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.839-843
    • /
    • 2001
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes are not seemed to be replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope able to maneuver safely in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfer momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjusting impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulation experiments show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

  • PDF

Large deflection behavior of a flexible circular cantilever arc device subjected to inward or outward polar force

  • Al-Sadder, Samir Z.
    • Structural Engineering and Mechanics
    • /
    • 제22권4호
    • /
    • pp.433-447
    • /
    • 2006
  • The problem of very large deflection of a circular cantilever arc device subjected to inward or outward polar force is studied. An exact elliptic integral solution is derived for the two cases and the results are checked using large displacement finite element analysis via the ANSYS package by performing a new novel modeling simulation technique for this problem. Excellent agreements have been obtained between the exact analytical solution and the numerical approach. From this study, a design chart for engineers is developed to predict the required value for the inward polar force for the device to switch on for a given angle forming the circular arc (${\theta}_o$). This study has several interesting applications in mechanical engineering, integrated circuit technology, nanotechnology and especially in microelectromechanical systems (MEMs) such as a MEM circular device switch subjected to attractive or repulsive magnetic forces due to the attachments of two magnetic poles at the fixed and at the free end of the circular cantilever arc switch device.