• Title/Summary/Keyword: Reproducibility of the results

Search Result 862, Processing Time 0.028 seconds

A Clinical Study on the Repeatability and Reproducibility of Portable Ryodoraku Device (포터블 양도락의 반복성.재현성에 대한 임상 연구)

  • Lee, Ji In;Ko, Seong Cheol;Song, Ho Sueb
    • Journal of Acupuncture Research
    • /
    • v.30 no.3
    • /
    • pp.135-140
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the repeatability and reproducibility of the Ryodoraku acupuncture device. For such device to be accepted as a good apparatus for clinical diagnosis, the score it provides should be stable no matter who measure it or when it is measured, assuming all other conditions equal. Materials and Methods : Three oriental medical doctors who were well trained and fully aware of the usage of the Ryodoraku acupuncture device examined ten randomly selected patients three times. Each doctor measured the Ryodoraku scores three times from each of the 10 selected patients. Three doctors were involved in this experiment to investigate the reproducibility and each of them measured the Ryodoraku scores three times from each patient to investigate the repeatability. Data was analyzed with Friedman test, Spearman correlation test, and intra-class correlation coefficient(ICC) in SPSS ver. 18. Results : 1. The Friedman test showed that there is no statistically significant difference between the 1st, 2nd and 3rd Ryodoraku scores measured by the same examiner. It indicates that the Ryodoraku acupuncture device provides the repeatability. 2. Spearman correlation test confirmed the results obtained by the Fiedman test by showing that there exists a strong positive correlation between the three Ryodoraku scores measured by the same examiner. 3. A very high ICC among the three examiner assured that the Ryodoraku acupuncture device achieves the reproducibility. Conclusions : The Ryodoraku acupuncture device achieves the repeatability and reproducibility. However, we still recommend that a doctor trained to a certain level use the Device to carry out the diagnosis. Also, to improve the device in terms of Reproducibility even more, it should be considered to provide a manual for the exact usage.

Reproducibility of a food frequency questionnaire: Korea Nurses' Health Study

  • Song, Sihan;Kim, Bohye;Pang, Yanghee;Kim, Oksoo;Lee, Jung Eun
    • Nutrition Research and Practice
    • /
    • v.16 no.1
    • /
    • pp.106-119
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: This study aimed to examine the reproducibility of food frequency questionnaires (FFQs) designed for young female nurses in the Korea Nurses' Health Study. SUBJECTS/METHODS: The reproducibility of web-based, self-administered FFQs was evaluated among 243 Korean female nurses. The first FFQ (FFQ1) was administered from March 2014 to February 2019 and the second FFQ (FFQ2) from November 2019, with a mean interval of 2.8 years between the FFQs (range, 9 months-5.6 years). Pearson and Spearman correlation coefficients (r values) and quartile agreements between FFQ1 and FFQ2 were calculated for intakes of energy, nutrients, and foods. RESULTS: Pearson correlation coefficients ranged from 0.41 to 0.55 (median r = 0.51) for energy and raw nutrients and from 0.16 to 0.46 (median r = 0.36) for energy-adjusted nutrients. Spearman correlation coefficients ranged from 0.25 to 0.72 (median r = 0.41) for food items. The percentages of women who were classified into the same or adjacent quartile were 77% to 84% (median = 82%) for raw nutrients and 69% to 86% (median = 78%) for foods. CONCLUSIONS: The results indicated that the web-based FFQ used in the Korea Nurses' Health Study has acceptable reproducibility.

Comparison of the reproducibility of panoramic radiographs between dentulous and edentulous patients

  • Park, Jong-Woong;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.95-102
    • /
    • 2014
  • Purpose: This study was performed to evaluate the reproducibility of panoramic radiographs of dentulous and edentulous patients. Materials and Methods: The reproducibility of panoramic radiographs was evaluated using the panoramic radiographs acquired from 30 anterior dentulous patients by using a common biting positioning device (dentulous group) and 30 anterior edentulous patients by using chin-support devices to take a panoramic radiograph (edentulous group), respectively; these patients had undergone 3 or more panoramic radiographs. The widths and angles between the designated landmarks were measured on the panoramic radiographs, and the reproducibility was evaluated using the intraclass correlation coefficient (ICC) and the coefficient of variation. Results: In the dentulous and edentulous groups, the ICCs of the mandibular ramus and mandibular angle areas were higher than the condylar head and zygomatic areas. The mandibular ramus and angle areas showed statistically lower mean coefficients of variation than the condylar head and zygomatic areas in the dentulous group. The mandibular angle area showed a significantly lower mean coefficient of variation than the zygomatic area in the edentulous group. By comparing the two groups, each ICC of the edentulous group was lower than that of the dentulous group, and the mean coefficients of variation of the mandibular ramus area, zygomatic area, left condylar inclination, and ramus ratio between the right and the left in the edentulous group were significantly higher than those in the dentulous group. Conclusion: Biting positioning for dentulous patients provided better positioning reproducibility than chin-support positioning when performing panoramic radiography for edentulous patients.

Validity and reproducibility of a food frequency questionnaire for breast cancer survivors in Korea

  • Sang-Eun, Moon;Woo-kyoung, Shin;Sihan, Song;Dahye, Koh;Jeong Sun, Ahn;Youngbum, Yoo;Minji, Kang;Jung Eun, Lee
    • Nutrition Research and Practice
    • /
    • v.16 no.6
    • /
    • pp.789-800
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: The aim of this study was to examine the validity and reproducibility of a food frequency questionnaire (FFQ) developed in Korea for breast cancer survivors. SUBJECTS/METHODS: Ninety-nine breast cancer survivors who completed an FFQ twice and three 3-day dietary records (DRs) between 2016-2017 were included. Energy and 14 nutrient intakes were calculated from FFQs and DRs. To determine the validity of the FFQ, energy-adjusted de-attenuated Pearson correlations between two FFQ assessments and the average of the three 3-day DRs were calculated, and to determine reproducibility, energy-adjusted Pearson correlations and degrees of agreement were calculated between the first and second FFQ assessments. RESULTS: Correlation coefficients of validity ranged from 0.29 (protein) to 0.47 (fat) (median value = 0.36) for the FFQ assessment and from 0.20 (riboflavin) to 0.53 (calcium) (median value = 0.37) for the second. Correlation coefficients of reproducibility ranged from 0.22 (sodium) to 0.62 (carbohydrate) (median value = 0.36). Regarding FFQ reproducibilities, percentage classifications of exact agreements for energy-adjusted nutrients ranged from 27.3% (sodium) and 45.5% (fat). A median 76.8% of participants were classified into the same or adjacent quartiles, while a median of 5.6% of participants were classified in extreme quartiles. Bland-Atman plots for the majority of data points of three macronutrients, calcium and vitamins A and C fell within limits of agreement. CONCLUSIONS: These results indicated that the newly developed FFQ for Korean breast cancer survivors has acceptable validity and reproducibility as compared with three 3-day DRs collected over a one-year period.

A Study on Reproducibility of Responses to the Questionnaire for Sasang Constitution Classification II (QSCC II) (사상체질분류검사(QSCC II)의 재현성에 관한 연구)

  • Cho, Jung-Hoon;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Hwang, Deok-Sang
    • The Journal of Korean Medicine
    • /
    • v.27 no.3 s.67
    • /
    • pp.145-150
    • /
    • 2006
  • Purpose: This study was conducted to investigate the reproducibility of responses to the QSCC II. Methods: Subjects have been tested by QSCC II for 2 or 3 successive years in Kangnam Korean Hospital at Kyunghee University from January 2002 to December 2005. We analyzed constitutions of the same subjects of each year tested. Results: In the second year of QSCC II assessment, 333 of the total 584 subjects were classed as the same constitutions as in their first test. The reproducibility was thus 56.88%. After the third year of QSCC II, 45 of a total 81 subjects were in the same constitutions. The reproducibility was thus 55.56%. Conclusions: We have found that the reproducibility of QSCC II is about 56%, so there is a severe limitation to diagnosis of constitution by QSCC II. Therefore, we must analyze constitutions through multiple objective methods.

  • PDF

Evaluation of the effect of abutment preparation angles on the repeatability and reproducibility using a blue light model scanner

  • Kim, Dong-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.210-217
    • /
    • 2020
  • PURPOSE. The purpose of the study is to evaluate the repeatability and reproducibility of the abutment angle using a blue light scanner. MATERIALS AND METHODS. 0°, 6°, and 10° wax cast abutment dies were fabricated. Each of the silicone impression was produced using the replicable silicone. Each study die was constructed from the prepared replicable stone used for scans. 3-dimensional data was obtained after scanning the prepared study dies for the repeatability by using the blue light scanner. The prepared 3-dimensional data could have the best fit alignment using 3-dimensional software. For reproducibility, each abutment was used as the first reference study die, and then it was scanned five times per each. 3-dimensional software was used to perform the best fit alignment. The data obtained were analyzed using a nonparametric Kruskal-Wallis H test (α=.05), post hoc Mann-Whitney U test, and Bonferroni correction (α=.017). RESULTS. The repeatability of 0°, 6°, and 10° abutments was 3.9, 4.4 and 4.7 ㎛, respectively. Among them, the 0° abutment had the best value while the 10° abutment showed the worst value. There was a statistically significant difference (P<.05). The reproducibility of 0°, 6°, and 10° abutments was 6.1, 5.5, and 5.3 ㎛, respectively. While the 10° abutment showed the best value, the 0° abutment showed the worst value. However, there was no statistically significant difference (P>.05). CONCLUSION. In repeatability, the 0° abutment showed a positive result. In reproducibility, the 10° abutment achieved a positive result.

Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colors

  • Tan, Fa-Bing;Wang, Chao;Dai, Hong-Wei;Fan, Yu-Bo;Song, Jin-Lin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2018
  • PURPOSE. The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS. A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (${\alpha}=.05$). RESULTS. In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to $20.88{\mu}m$), of which the marginal and internal variations ranged $51.36-58.26{\mu}m$ and $18.33-20.04{\mu}m$, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than $5{\mu}m$, of which blue color group was the smallest ($3.27{\pm}0.24{\mu}m$) and white color group was the largest ($4.24{\pm}0.36{\mu}m$). These results were consistent with the DS data. CONCLUSION. The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.

A study on the reproducibility of the natural head position according to the skeletal malocclusion types and sex (부정교합의 유형과 성별에 따른 자연두부위치의 재현성에 관한 연구)

  • Kim, Ha-Ran;Lee, Dong-Yul;Kim, Kwang-Won;Yoon, Young-Jooh
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.307-315
    • /
    • 2000
  • This study was performed to evaluate the reproducibility of natural head position according to skeletal malocclusion types and sex using cephalometric radiographs for establishing orthodontic diagnosis and treatment planning. The sample consisted of 90 young adults (male 45, female 45) who had the skeletal malocclusion. Cephalometric radiographs were taken in natural head position, and statistical analysis was performed and method error of 6 postural variables were estimated to evaluate the reproducibility of the natural head position. The following results were obtained : 1. In the reproducibility of the natural head position, postural variables had no statistical significance In male and female (P>0.05). 2. In the reproducibility of the natural head position, postural variables had no statistical significance in Class I, II, III, and total group (P>0.05). 3. The reproducibility of natural head position using method error was excellent in all groups.

  • PDF

Reproducibility of the Isokinetic Joint Torque as a Rotator Cuff Weakness Test Protocol in Patients With Rotator Cuff Tendinitis

  • Kim, Soo-yong;Oh, Jae-seop
    • Physical Therapy Korea
    • /
    • v.24 no.3
    • /
    • pp.21-29
    • /
    • 2017
  • Background: The measurement of the strength of the shoulder muscles is an important element of the overall assessment of patients with various shoulder disorders. However, the clinical utilization of this measurement is dependent on its reproducibility. Objects: To explore the reproducibility of the measurements derived from testing of the isokinetic strength of shoulder muscles in patients with tendinitis of the rotator cuff. Methods: A total of 20 patients with tendinitis of the rotator cuff participated in this study and were assessed twice in 1 week. Isokinetic testing was performed concentrically for shoulder flexors, abductors, and external rotators and eccentrically for the shoulder extensors, adductors, and internal rotators. The relative and absolute reproducibility of the peak torque (PT) and ratios were assessed using intra-class correlation coefficients (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID), respectively. Results: Overall, high to excellent ICC, clinically acceptable SEM and MCID values were obtained for the PT (ICC: .83-.95, SEM: 1.2%-9%, MCID: 3.4%-25%) and ratios (ICC: .85-.93, SEM: 5.1%-10%, MCID: 14.2%-27.6%). Conclusion: These findings suggest that isokinetic tests may be effectively utilized for the determination of shoulder strength profiles and appropriate position are recommended to perform test without pain in patients with tendinitis of the rotator cuff.

A Comparison on the Reproducibility of Parametric Bodies Used in the Virtual Garment System

  • Choi, Hee Eun;Nam, Yun Ja;Kim, Hye Suk
    • Fashion & Textile Research Journal
    • /
    • v.16 no.2
    • /
    • pp.266-274
    • /
    • 2014
  • Parametric bodies reproduce the actual shape of human body parts and should be convenient for general users to change size to judge the visual fit of clothes on-line. In this study, three parametric bodies(i.e. I, C, D ) were compared to verify the accuracy of the provided body dimensions and reproducibility to a target model. To compare reproducibility, the 20s female standard virtual model developed for an apparel industry by Korean agency for technology and standards is used. The investigation of existing parameters showed that the numbers and kinds of parameters provided by each program were different with some errors in notation; in addition, some of virtual body dimensions went beyond the maximum allowable error. The result of changing each parametric body to the 20s female standard body showed that D, C, I in order produced better reproducibility for body dimensions. There were different levels of protrusion and concavity in the virtual cross sections and virtual longitudinal sections despite the small differences in body dimensions and cross sectional areas; in addition, some parametric body was not bilateral symmetry. The results of this study can be used as basic information in the standardization of a virtual model used in a virtual garment program.