Background: The motor unit number index (MUNIX) and motor unit size index (MUSIX) refer to the electrophysiological measurement of the motor units using the surface electromyographic interference pattern (SIP) recorded during graded muscle contraction. In order to improve the reliability and reproducibility of MUNIX by the systematization of the graded muscle contractions, we applied a digital hand instrument to the procedure of recording SIP signals. Methods: We tested the applicability of the digital instrument in the MUNIX technique by assessing the mean values and the reproducibility of the MUNIX involving the abductor pollicis brevis (APB) and the abductor digiti minimi (ADM) muscles in 30 healthy adults. Results: The digital dynamometer was successfully applied to the MUNIX measurements of the APB and ADM muscles, and showed high reproducibility across trials. Conclusions: Application of the digital instrument would be useful in improving the reliability and reproducibility of MUNIX.
The Transactions of The Korean Institute of Electrical Engineers
/
v.58
no.6
/
pp.1246-1254
/
2009
The reproducibility of initial value and change over time of surface EMG spike variables(MSA, MSF, MSS, MSD) was investigated in the biceps brachii muscle of 11 healthy subjects. Surface EMG signals were recorded during sustained isometric voluntary contractions for 30 seconds at three contraction levels, 20%, 50%, and 80%MVC, respectively. Each contraction was repeated three times in each of three different days for a total of nine contractions and 99 contractions per %MVC level across the eleven subjects. A total of 297 EMG signals across the different trials, days, subjects, and %MVC levels was saved for the subsequent analysis. The degree of reproducibility was investigated using the intraclass correlation coefficient(ICC) and the standard error of the mean(SEM) based upon the analysis of variance(ANOVA), Results for intercept showed higher reproducibility of the spike variables with about 60%-98% ICC than the variable(ARV, MNF) which had been analyzed before in other researches. And results for slope showed poor reproducibility of the spike variables with about 30%-70% ICC and they were comparable with the variables of other researches.
Purpose: This study was conducted to investigate the reproducibility of responses to the QSCC II. Methods: Subjects have been tested by QSCC II for 2 or 3 successive years in Kangnam Korean Hospital at Kyunghee University from January 2002 to December 2005. We analyzed constitutions of the same subjects of each year tested. Results: In the second year of QSCC II assessment, 333 of the total 584 subjects were classed as the same constitutions as in their first test. The reproducibility was thus 56.88%. After the third year of QSCC II, 45 of a total 81 subjects were in the same constitutions. The reproducibility was thus 55.56%. Conclusions: We have found that the reproducibility of QSCC II is about 56%, so there is a severe limitation to diagnosis of constitution by QSCC II. Therefore, we must analyze constitutions through multiple objective methods.
PURPOSE. The purpose of the study is to evaluate the repeatability and reproducibility of the abutment angle using a blue light scanner. MATERIALS AND METHODS. 0°, 6°, and 10° wax cast abutment dies were fabricated. Each of the silicone impression was produced using the replicable silicone. Each study die was constructed from the prepared replicable stone used for scans. 3-dimensional data was obtained after scanning the prepared study dies for the repeatability by using the blue light scanner. The prepared 3-dimensional data could have the best fit alignment using 3-dimensional software. For reproducibility, each abutment was used as the first reference study die, and then it was scanned five times per each. 3-dimensional software was used to perform the best fit alignment. The data obtained were analyzed using a nonparametric Kruskal-Wallis H test (α=.05), post hoc Mann-Whitney U test, and Bonferroni correction (α=.017). RESULTS. The repeatability of 0°, 6°, and 10° abutments was 3.9, 4.4 and 4.7 ㎛, respectively. Among them, the 0° abutment had the best value while the 10° abutment showed the worst value. There was a statistically significant difference (P<.05). The reproducibility of 0°, 6°, and 10° abutments was 6.1, 5.5, and 5.3 ㎛, respectively. While the 10° abutment showed the best value, the 0° abutment showed the worst value. However, there was no statistically significant difference (P>.05). CONCLUSION. In repeatability, the 0° abutment showed a positive result. In reproducibility, the 10° abutment achieved a positive result.
Journal of the Korea Institute of Building Construction
/
v.16
no.1
/
pp.25-34
/
2016
From 1990's, a study on the development of exothermic concrete, a concrete which electro-conductive material is mixed, has been proceeded. However, due to the difficulty of exothermic reproducibility of concrete specimen, the study has been unable to continuously carried out. Accordingly, this study was focused on developing an exothermic concrete for the purpose of snow-melting material. Cement paste and mortar specimens mixed with graphite, conductive metal powder and chemical admixture were made. The evaluation of exothermic performance and reproducibility was conducted under $-2^{\circ}C$ of low temperature. In addition, micro-chemical analysis was carried out to investigate a cause of exothermic reproducibility. As a test result, the specimen mixed with graphite and superplasticizer with air entrained showed the best exothermic performance and reproducibility. Through micro-chemical analysis, it is judged that polymer or methacrylic acid (MAA), the contents inside the superplasticizer with air entrained, gave exothermic reproducibility by generating the electrochemical reaction with graphite.
Kim, Ha-Ran;Lee, Dong-Yul;Kim, Kwang-Won;Yoon, Young-Jooh
The korean journal of orthodontics
/
v.30
no.3
s.80
/
pp.307-315
/
2000
This study was performed to evaluate the reproducibility of natural head position according to skeletal malocclusion types and sex using cephalometric radiographs for establishing orthodontic diagnosis and treatment planning. The sample consisted of 90 young adults (male 45, female 45) who had the skeletal malocclusion. Cephalometric radiographs were taken in natural head position, and statistical analysis was performed and method error of 6 postural variables were estimated to evaluate the reproducibility of the natural head position. The following results were obtained : 1. In the reproducibility of the natural head position, postural variables had no statistical significance In male and female (P>0.05). 2. In the reproducibility of the natural head position, postural variables had no statistical significance in Class I, II, III, and total group (P>0.05). 3. The reproducibility of natural head position using method error was excellent in all groups.
An observation and evaluation of the reproducibility of the mandibular movements has been a integral part of a test for mandibular function and dysfunction. After Pantographic Reproducibility Index(PRI) was introduced in dentistry, many authors have used the index for investigation of mandibular movement function, especially in condylar compartment. Howerer, the difficult and time-consuming work of instrumentation for getting the PRI has been a major obstacle in using pantograph. This study was performed to try a new mandibular reproducibility index, so-called BioEGN reproducibility index(BERI), calculated from mandibular trajectory recorded with BioEGN. 26 dental students without any signs and symptoms of temporomandibular disorders and 22 patients with temporomandibular disorders took part in this study and classed to control group and patients group, respectively. Pantronic and BioEGN were used to record and calculate the indices, PRI and BERI. PRI had only one value, but BERI had two values of outgoing and incoming movement in each scale. With two scales of small and large, as a result, BERI had four values in this study. PRI corresponded to BERI in small scale on outgoing total movements. The data were calculated and analyzed with SAS/stat program and the conclusion of this study were as follows : 1. In every scales, in each movement, BERI on outgoing movement in control group was lower than that in patients group, respectively, but BERI on incoming movement was only different in one side movement, that was, left excursion. 2. The difference between BERI on outgoing movement and BERI on incoming movement was only shown in small scale on total movements, not in each movement, in control group. However, there was generally a positive correlationship between BERI on outgoing movement and BERI on incoming movement in each movement in both groups. 3. Simple statistics of PRI was similar to that of BERI on total movements in small scale, but there was a negative correlation between PRI and BERI on total movements in large sclae only in patients group.
Kim, Soo-Kyung;Choi, Eun-Hee;Lee, Jung-Seok;Kim, Tae-Gyun;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
Journal of Periodontal and Implant Science
/
v.40
no.4
/
pp.172-179
/
2010
Purpose: Accurate and exact measurement is an important factor for generating meaningful results in any properly designed study. If all the participating examiners are able to yield similar results, it will be possible to evaluate the objective results of the study more easily and quickly. The purpose of this study was to evaluate the intra- and inter-examiner reproducibility of histometric measurements in the intrabony periodontal defect model. Methods: One wall intrabony defects were surgically created at the distal aspect of the second and the medial aspect of the fourth mandibular premolars in the right and left jaw quadrants in twenty beagle dogs and the defect sites received the following ${\beta}$-tri calcium phosphate, growth differentiation factor-0, growth differentiation factor-100 and sham surgery. Histometric analysis was performed after 8 weeks. Histometric parameters were recorded and repeated at three months interval by three examiners. Intra- and inter-examiner reproducibility was assessed. Results: Most parameters of all the groups showed high intra- and inter-examiner reproducibility. Parameters including defect height, bone regeneration height, cementum regeneration height, and formation of junctional epithelium yielded interexaminer correlation ${\geq}0.9$. The intra-examiner reproducibility showed a high result, over 0.9. Conclusions: Histometric evaluation of the one-wall intra-alveolar periodontal defect model showed high reproducibility not only for a single given examiner but also among the three examiners.
Objectives : The purpose of this study is to investigate the repeatability and reproducibility of the Ryodoraku acupuncture device. For such device to be accepted as a good apparatus for clinical diagnosis, the score it provides should be stable no matter who measure it or when it is measured, assuming all other conditions equal. Materials and Methods : Three oriental medical doctors who were well trained and fully aware of the usage of the Ryodoraku acupuncture device examined ten randomly selected patients three times. Each doctor measured the Ryodoraku scores three times from each of the 10 selected patients. Three doctors were involved in this experiment to investigate the reproducibility and each of them measured the Ryodoraku scores three times from each patient to investigate the repeatability. Data was analyzed with Friedman test, Spearman correlation test, and intra-class correlation coefficient(ICC) in SPSS ver. 18. Results : 1. The Friedman test showed that there is no statistically significant difference between the 1st, 2nd and 3rd Ryodoraku scores measured by the same examiner. It indicates that the Ryodoraku acupuncture device provides the repeatability. 2. Spearman correlation test confirmed the results obtained by the Fiedman test by showing that there exists a strong positive correlation between the three Ryodoraku scores measured by the same examiner. 3. A very high ICC among the three examiner assured that the Ryodoraku acupuncture device achieves the reproducibility. Conclusions : The Ryodoraku acupuncture device achieves the repeatability and reproducibility. However, we still recommend that a doctor trained to a certain level use the Device to carry out the diagnosis. Also, to improve the device in terms of Reproducibility even more, it should be considered to provide a manual for the exact usage.
Background: The measurement of the strength of the shoulder muscles is an important element of the overall assessment of patients with various shoulder disorders. However, the clinical utilization of this measurement is dependent on its reproducibility. Objects: To explore the reproducibility of the measurements derived from testing of the isokinetic strength of shoulder muscles in patients with tendinitis of the rotator cuff. Methods: A total of 20 patients with tendinitis of the rotator cuff participated in this study and were assessed twice in 1 week. Isokinetic testing was performed concentrically for shoulder flexors, abductors, and external rotators and eccentrically for the shoulder extensors, adductors, and internal rotators. The relative and absolute reproducibility of the peak torque (PT) and ratios were assessed using intra-class correlation coefficients (ICC), standard error of measurement (SEM), and minimal clinically important difference (MCID), respectively. Results: Overall, high to excellent ICC, clinically acceptable SEM and MCID values were obtained for the PT (ICC: .83-.95, SEM: 1.2%-9%, MCID: 3.4%-25%) and ratios (ICC: .85-.93, SEM: 5.1%-10%, MCID: 14.2%-27.6%). Conclusion: These findings suggest that isokinetic tests may be effectively utilized for the determination of shoulder strength profiles and appropriate position are recommended to perform test without pain in patients with tendinitis of the rotator cuff.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.