• Title/Summary/Keyword: Report Generator

Search Result 90, Processing Time 0.028 seconds

Numerical Analysis for Reduction of Fuel Consumption by Improvement of Combustion Condition in a Common Rail Diesel Engine Generator (커먼레일 디젤엔진 발전기의 연소상태 개선에 따른 연비절감을 위한 수치해석)

  • Kim, Seung Chul;Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.4
    • /
    • pp.58-64
    • /
    • 2016
  • The main engine of a vehicle is used an common rail diesel engine for improving the efficiency of the whole load area. However, the generator engines is still used mechanical fuel injection valve drive cams. In addition, most of generator engines is applied a part-load operation of less than 50%. Therefore, diesel engine of vehicle set at 100% load is necessary to readjust in order to perform efficient operation because of part-load operation. In this study, the objective is to report the results of the part-load fuel consumption improvement by injection timing readjust to identify the operational characteristics of a generator engine currently operated in the facilities.

Wound Infection of Spinal Cord Stimulator: A Case Report (척수 신경 자극기 삽입부 감염의 치험례)

  • Kim, Jong-Sok;Oh, Deuk-Young;Seo, Je-Won;Lee, Jung-Ho;Rhie, Jong-Won;Ahn, Sang-Tae
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.71-74
    • /
    • 2010
  • Purpose: Nowadays spinal cord stimulator is frequently used for the patients diagnosed as complex regional pain syndrome. The lead is placed above the spinal cord and connected to the stimulation generator, which is mostly placed in the subcutaneous layer of the abdomen. When the complication occurs in the generator inserted site, such as infection or generator exposure, replacement of the new generator to another site or pocket of the abdomen would be the classical choice. The objective of our study is to present our experience of the effective replacement of the existing stimulation generator from subcutaneous layer to another layer in same site after the wound infection at inexpensive cost and avoidance of new scar formation. Methods: A 50-year-old man who was diagnosed as complex regional pain syndrome after traffic accident received spinal cord stimulator, Synergy$^{(R)}$ (Medtronic, Minneapolis, USA) insertion 1 month ago by anesthetist. The patient was referred to our department for wound infection management. The patient was presented with erythema, swelling, thick discharge and wound disruption in the left upper quadrant of the abdomen. After surgical debridement of the capsule, the existing generator replacement beneath the anterior layer of rectus sheath was performed after sterilization by alcohol. Results: Patient's postoperative course was uneventful without any complication and had no evidence of infection for 3 months follow-up period. Conclusion: Replacement of existing spinal cord stimulation generator after sterilization between the anterior layer of rectus sheath and rectus abdominis muscle in the abdomen will be an alternative treatment in wound infection of stimulator generator.

Wolsong Unit 1 Steam Generator Aging Management for Continued Operation (월성 1호기 계속운전을 위한 증기발생기 열화관리)

  • Song, Myung Ho;Kim, Hong Key;Lee, Jung Min
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.28-33
    • /
    • 2010
  • As a part of license renewal for the continued operation of Wolsong unit 1, the periodic safety review report was submitted near the end of design lifetime, 2012, and now is under reviewing. Major components of primary system such as pressure tubes, feeder pipes and so on are being replaced and many components of secondary system are also being repaired. So the license renewal of Wolsong unit 1 is expected to be acquired without significant issues. But on the other hand, steam generators of Wolsong unit 1 had the good performance and therefore the replacement and repair for the steam generator are not needed. Recently it is reported that some cracks were detected in a few of european steam generator with Alloy 800 tubes and the cause of cracks was the outer diameter stress corrosion cracking(ODSCC) due to the concentration of chemical impurities on the outer surface of tube. Accordingly the overall review on this issue was performed. The long-term operation is likely to results to form the concentration mechanism for the tube corrosion as the sludge build-up in the secondary side of steam generator and the crack in the crevice between tube and tube-sheet and expansion transitions is apt to be occurred. In this paper, the history of steam generator inspection and operation of Wolsong unit 1 are reviewed and the reliability of steam generator tube is evaluated and the steam generator aging management program for Wolsong unit 1 is introduced.

  • PDF

An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters

  • Kim, Young-gon;Kwon, Jung Ah;Moon, Yeonsook;Park, Seong Jun;Kim, Sangwook;Lee, Hyun-A;Ko, Sun-Young;Chang, Eun-Ah;Nam, Myung-Hyun;Lim, Chae Seung;Yoon, Soo-Young
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.512-517
    • /
    • 2018
  • Background: Complete blood count (CBC) results play an important role in peripheral blood smear (PBS) examinations. Many descriptions in PBS reports may simply be translated from CBC parameters. We developed a computer program that automatically generates a PBS draft report based on CBC parameters and age- and sex-matched reference ranges. Methods: The Java programming language was used to develop a computer program that supports a graphical user interface. Four hematology analyzers from three different laboratories were tested: Sysmex XE-5000 (Sysmex, Kobe, Japan), Sysmex XN-9000 (Sysmex), DxH800 (Beckman Coulter, Brea, CA, USA), and ADVIA 2120i (Siemens Healthcare Diagnostics, Eschborn, Germany). Input data files containing 862 CBC results were generated from hematology analyzers, middlewares, or laboratory information systems. The draft reports were compared with the content of input data files. Results: We developed a computer program that reads CBC results from a data file and automatically writes a draft PBS report. Age- and sex-matched reference ranges can be automatically applied. After examining PBS, users can modify the draft report based on microscopic findings. Recommendations such as suggestions for further evaluations are also provided based on morphological findings, and they can be modified by users. The program was compatible with all four hematology analyzers tested. Conclusions: Our program is expected to reduce the time required to manually incorporate CBC results into PBS reports. Systematic inclusion of CBC results could help improve the reliability and sensitivity of PBS examinations.

Seismic Response Analysis of Steam Turbine-Generator Rotor System (2nd Report, Application of Wavelet Analysis) (증기터빈$\cdot$발전기축계의 지진응답해석 (제2보 : 웨이블렛 해석의 적용))

  • 양보석;김병욱;김용한
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.813-821
    • /
    • 1999
  • This paper presents the technique using wavelet analysis to solve the seismic response of a steam turbine-generator rotor system subjected to earthquake excitations. A brief review of the wavelet transform and its discretization, time-frequency representation of the earthquake wave and the seismic response for a rotor system is presented. The Daubechies wavelet has been used for describing the time-frequency characteristics of the input and the response in case of a recorded accelerogram during 1995 Hyogoken Nanbu earthquake. Also, the results in the wavelet domain has been illustrated through comparison with the time domain simulation results.

  • PDF

Elevation of Depressed Skull Fracture with a Cup of Breast Pump and a Suction Generator : A Case Report in Technical Aspects

  • Kim, Young-Jin;Lee, Sang-Koo;Cho, Maeng-Ki;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.346-348
    • /
    • 2007
  • Surgical elevation of the depressed bone is known to be the conventional treatment usually recommended for a simple depressed skull fracture in the adult or pediatric age. The authors introduce, however, a case of depressed skull fracture in an infant which was elevated by means of a cup of breast pump and a suction generator without surgical elevation. In our case, without surgery, a 'cup-shaped' depressed skull fracture in an infant was safely elevated with no neurological signs. This method is considered a simple, effective, safe, and alternative procedure in an infant with simple depressed skull fracture.

Governor upgrade for PWR NPP safety related Emergency Diesel Generator (경수로형 원자력 안전등급 비상디젤발전기)

  • Kim, Yoon Sik;Jeon, Il-Young;Song, Dong-Young;Kim, Chang-Kook;Sim, Su-Il
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.293-298
    • /
    • 2005
  • The following is final report for governor upgrade for PWR NPP safety related EDG Kori NPP No.2 Unit. The upgraded system includes more beneficial function like as "Slow start with starting ramp", "Generator load sensing & control capability" and "Emergency ramp during slow start". This paper show functional operation of slow start regime according to NRC regulatory guide which guide regulation to NPP safety related environment.

  • PDF

Rocket Engine Test Facility Improvement for Hot Firing Test of 75 ton-f Class Gas Generator and Cold Flow Test (75톤급 가스발생기 연소시험을 위한 시험장 개선 및 수류시험)

  • Kang, Dong-Hyuk;Lim, Byoung-Jik;Ahn, Kyu-Bok;Seo, Seong-Hyeon;Han, Yeoung-Min;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.29-33
    • /
    • 2009
  • On the basis of the development experience of a gas generator for the 30 ton-f thrust liquid rocket engine combustor a Subscale Ground Firing Test Facility was designed and fabricated for a gas generator for the 75 ton-f thrust liquid rocket engine combustor. The Subscale Ground Firing Test Facility developed is going to be used to develop 75 ton-f class gas generator. Acquired data and test technique from this facility will be used to develope the high performance liquid rocket engine combustor and the Ground Firing Test Facility. This report describes the improved Subscale Ground Firing Test Facility for 75 ton-f class gas generator and results of the cold flow test.

  • PDF

Lateral Third Infraclavicular Implantation of the Vagal Nerve Stimulation Generator Through Axillary Incision

  • Lee, Young-Jae;Kim, Jae-Woo;Kim, Ik-Soo;Lee, Myung-Ki;Ghang, Chang-Ghue;Lee, Young-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.1
    • /
    • pp.16-19
    • /
    • 2007
  • Objective : This report describes the clinical study of the surgical method of lateral third infraclavicular implantation of vagal nerve stimulation (VNS) generator through the axillary wrinkle incision. Methods : In a retrospective study, the data for 20 patients with medically intractable epilepsy treated by this approach were examined. The mean age was 31.4 years (range : 14-50), and the mean follow-up period was 12.15 months (range : 4-21 months). The male to female ratio was 2.3 : 1. The subcutaneous pocket for the generator was located in the lateral third infraclavicular area through the axillary wrinkle. Our method was a modification of the standard VNS generator implantation in the mid-infraclavicular pocket through anterior axillary incision. Results : There were the excellent or good cosmetic satisfaction in 95% of the cases and fair in 5%. The generator was located outside the lung field in 15%, periphery of the lung field in 45%, and crossed over the lung field in 40%. Discomfort from shoulder motion occurred transiently in 35% of cases. Other complications were minimal. Conclusion : These results demonstrate that the lateral third infraclavicular apporach will offers cosmetic benefits and reduction of obscuration of the lung field without serious complications. Thus, this technique provides an attractive alternative among the surgical techniques for the vagal nerve stimulation.

Wolsong 3&4 Steam Generator Tube Inspection (월성 3,4호기 증기발생기 전열관 검사)

  • Jang, Kyoung-Sik;Kwon, Dong-Ki;Choi, Jin-Hyuk;Son, Tai-Bong
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.859-866
    • /
    • 2001
  • During the Pre-service Inspection for Wolsong Unit 3&4 in 1997/1998 respectively, 17 Distorted Roll Transition indications(over expanded beyond tubesheet secondary face) were identified at the Unit 4 (S/G B, D). Six(6) tubes out of these tubes were plugged in 1998. However the first Periodic Inspection identified additional 110 indications in 1999 and 2000. The additionally identified 110 indication call, not reported at the Pre-service Inspection, are; 2 Not-Finally-Expanded-Tubes and 108 Distorted Roll Transition tubes. Design limit of each Steam Generator tube Plugging is 6.4%. Plugging was performed by the Steam Generator manufacturer under the warranty. When Distorted Roll Transition indications were first identified on the Unit 4 in 1998 the degree of Over-expansion was measured using an inner dial-gage to make the disposition of Nonconformance report. 2 Not-Finally-Expanded-Tubes were plugged and 10 tubes out of 108 Distorted Roll Transition Tubes were also plugged as a preventive measure.

  • PDF