• Title/Summary/Keyword: Repetition rate

Search Result 434, Processing Time 0.025 seconds

A Study on Efficiency Improvement and Optimization of Operating Characteristics of Pulsed $CO_2$ Laser System using Ring Blower (링 블로우를 이용한 펄스형 $CO_2$ 레이저 시스템의 효율 향상과 동작 특성에 관한 연구)

  • Kim, D.H.;Chung, H.J.;Park, S.J.;Joung, J.H.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.57-60
    • /
    • 2000
  • In this paper, it is purpose to develop a pulsed $CO_2$ laser with stable output at pulse repetition rate range of 2 KHz. We used a IGBT as a switching device. The laser cavity was fabricated as an axial and water cooled type. It was used a ring blower to increase a cooling effect The laser performance characteristics as parameters, such as pulse repetition rate, gas pressure have been investigated. The experiment was done under 3 electrode-type instead of 2 electrode-type. To achieve 3 electrode-type, we used two pulse-transformers which is operated parallel. As a result, the maximum output was about 28 W at the total pressure of 20 Torr, the gas mixture $Co_2$:$N_2$:He=1:9:15 and the pulse repetition rate of 1300 Hz.

  • PDF

Output characteristics of ac excited $CO_2$ laser as a adjusting a phase angle and frequency (위상각와 주파수 제어에 따른 상용주파 AC 여기 방식의 펄스형 $CO_2$ 레이저 전원장치 개발에 관한 연구)

  • Chung, Hyun-Ju;Kim, Do-Wan;Lee, Dong-Hoon;Kim, Joong-Mann;Kim, Mee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2098-2100
    • /
    • 2000
  • We propose pulsed $CO_2$ laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch) circuit and a PIC one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum laser output was obtained about 23W at pulse repetition rate of 60Hz, total gas mixture of $CO_{2}/N_{2}$/He = 1/9/15, SCR gate trigger angle 90$^{\circ}$, and total pressure of 18Torr.

  • PDF

A Study on Efficiency Improvement and Optimization of Operating Characteristics of Pulsed $CO_2$ Laser System using 3 Electrode-type and Ring Blower (3전극 방식과 링 블로우를 이용한 펄스형 $CO_2$ 레이저 시스템의 효율 향상과 동작 특성에 관한 연구)

  • Kim, D.W.;Chung, H.J.;Park, S.J.;Lee, Y.S.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2101-2103
    • /
    • 2000
  • In this paper, it is purpose to develop a pulsed $CO_2$ laser with stable output at pulse repetition rate range of 2 kHz. We used a IGBT as a switching device. The laser cavity was fabricated as an axial and water cooled type. It was used a ring blower to increase a cooling effect. The laser performance characteristics as parameters, such as pulse repetition rate, gas pressure have been investigated. The experiment was done under 3 electrode-type instead of 2 electrode-type. To achieve 3 electrode-type, we used two pulse-transformers which is operated parallel. As a result. the maximum output was about 28 W at the total pressure, of 20 Torr(the gas mixture $CO_2$:$N_2$:He=1:9:15 and the pulse repetition rate of 1300 Hz).

  • PDF

Commercial frequency AC discharge magnetic stimulation operating characteristics (상용교류방전 자기자극장치의 동작특성)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2685-2692
    • /
    • 2009
  • We propose pulsed magnetic stimulation below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control magnetic stimulation output. In this magnetic stimulation, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch)circuit and a DSP & FPGA are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum magnetic stimulation output was obtained about 33W at pulse repetition rate of 60Hz, total 40, 80, 120, $160^{\circ}$, SCR gate trigger angle $90^{\circ}$ and total output.

Effect of Pulse Energy and Pulse Repetition Rate at the Identical Total Power During Enamel Ablation Using an Er:YAG Laser (Er:YAG 레이저를 이용한 치아 삭제시 동일출력에서 펄스에너지와 조사반복률의 영향)

  • Won, Jung-Yeon;Kim, Mee-Eun;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.3
    • /
    • pp.223-229
    • /
    • 2006
  • The objectives of this study was to investigate the amount of tooth ablation and the change of intrapulpal temperature by Er:YAG laser as it relates to pulse energy and pulse repetition rate at the identical power and, thereby, to reveal which of the two parameters strongly relates with ablation efficiency and intrapulpal temperature. Extracted healthy human molar teeth were sectioned into two pieces and each specimen was irradiated within the combination of pulse energy and pulse repetition time at the same power of 3W; $300mJy{\times}10Hz$ group, $200mJy{\times}15Hz$ group, and $150mJy{\times}20Hz$ group. Each specimen comprised ten tooth specimens. A laser beam with conjunction of a water flow rate of 1.6 ml/min was applied over enamel surfaces of the specimens during 3 seconds and the ablation amount was determined by difference in weight before and after irradiation. To investigate the temperature change in the pulp according to the above groups, another five extracted healthy human molar teeth were prepared. Each tooth was embedded into resin block and the temperature-measuring probes were kept on the irradiated and the opposite walls in the dental pulp during lasing. When the power was kept constant at 3W, ablation amount increased with pulse energy rather than pulse repetition rate (p=0.000). Although intrapulpal temperature increased with pulse repetition rate, there were no significant differences among the groups and between the irradiated and the opposite pulpal walls, except at a condition of $150y{\times}20Hz$ (p=0.033). Conclusively, it is suggested that ablation efficacy is influenced by pulse energy rather than pulse repetition rate.

ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY OF ENAMEL AND DENTIN (Er:YAG 레이저의 법랑질 및 상아질의 삭제효과 비교)

  • Hong, Seong-Su;Lee, Sang-Ho;Lee, Chang-Seop;Kim, Su-Gwan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.4
    • /
    • pp.728-734
    • /
    • 2001
  • The purpose of this study was to investigate the effects of Er:YAG laser on cutting of efficacy of enamel and dentin in primary and permanent teeth. We used the enamel and dentin specimens of human teeth which contain the physiologic saline and maintain the pulpal pressure in dentinal tubules. Each specimen was exposed to Er:YAG laser with non-contact mode under different treatment condition of irradiation energy, pulse repetition rate. We investigated the cutting efficacy of Er:YAG laser by Scanning Intensity Microscopy, and obtained following results. 1. Cutting volume of enamel and dentin in primary and permanent teeth were increased by increasing the irradiation energy, pulse repetition rate. 2. Cutting volume of primary teeth was larger than that of permanent teeth. 3. Cutting volume of dentin was larger than that of enamel in primary and permanent teeth. From these results, Er:YAG laser would be more effective in cutting dentin than enamel, and in cutting primary teeth than permanent teeth for clinical application.

  • PDF

Convolutionally-Coded and Spectrum-Overlapped Multicarrier DS-CDMA Systems in a Multipath Fading Channel

  • Oh, Jung-Hun;Kim, Ki-Doo;Milstein, Laurence B.
    • ETRI Journal
    • /
    • v.23 no.4
    • /
    • pp.177-189
    • /
    • 2001
  • Multicarrier DS-CDMA is an effective approach to combat fading and various kinds of interference. In this paper, we present an overlapped multicarrier DS-CDMA system, wherein each of the rate 1/M convolutionally-encoded symbols is also repetition coded and transmitted using overlapped multicarriers. However, since the frequency spectrums of successive carriers are allowed to overlap, the transmission bandwidth is more efficiently utilized. The effect of the overlapping percentage between successive carriers of a multicarrier DS-CDMA system on the performance is investigated to determine the overlapping percentage showing the best performance. We suggest two methods for sub-band overlapping variation. One is to allow variation of sub-band overlapping percentage when the total number of subcarriers is fixed. The other is to increase the number of sub-bands (the number of repetitions R) with fixed sub-band bandwidth. Given a total number of subcarriers MR, we show that the BER variation is highly dependent on the roll-off factor ${\beta}$ of a raised-cosine chip wave-shaping filter irrespective of convolutional encoding rate 1/M and repetition coding rate 1/R. We also analyze the possibility of reduction in total multi-user interference by considering the variation of both the roll-off factor ($0<{\beta}{\leq}1$) and the sub-band overlapping factor ($0<{\lambda}{\leq}2$), and show that the proposed system may outperform the multicarrier DS-CDMA system in [3].

  • PDF

The flux pinning properties of BaSnO3-added GdBa2Cu3O7-δ films with varying growth conditions

  • Lee, J.K.;Oh, J.Y.;Lee, J.M.;Kang, W.N.;Kang, B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.3
    • /
    • pp.18-22
    • /
    • 2017
  • Addition of $BaSnO_3$ (BSO) to $GdBa_2Cu_3O_{7-{\delta}}$ (GdBCO) is reported to enhance the flux pinning property of GdBCO thick films. To investigate the effect of growth condition on the pinning properties, 700 nm-thick BSO-added GdBCO films deposited with varying temperatures and growth rates were prepared by using a pulsed laser deposition method. As the deposition temperature increases, the critical current density and the pinning force density show an improved field dependence up to $750^{\circ}C$ due to the increase in the formation of the a-axis growth and the BSO nanostructures. The films deposited at higher temperatures show degraded surfaces and as a result, degraded pinning behaviors. For the change in growth rate, the critical current density and the pinning force increase as the repetition rate increase at low magnetic fields, but this behavior is reversed in high magnetic fields. These results indicate that the film growth conditions significantly affect the formation of BSO nanostructures and the pinning properties of BSO-added GdBCO films.

INHIBITORY EFFECT OF DENTAL LASERS ON THE GROWTH AND THE FUNCTION OF STREPTOCOCCUS MUTANS (각종 치과레이저의 Streptococcus mutans에 대한 증식 및 기능억제 효과)

  • Han, Kang-Seog;Kook, Joong-Ki;You, So-Young;Kim, Hwa-Sook;Park, Jong-Whi;Park, Heon-Dong;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.439-447
    • /
    • 2003
  • This was performed to evaluate the inhibitory effect of laser on the growth of S. mutans. The bacterial pallets containing S. mutans KCTC 3065 were irradiated with Er:YAG laser and Nd :YAG laser by non-contact method at an intensity of 50mJ for 5 sec with the pulse repetition rates of 10Hz and 30Hz, respectively. The following results were obtained on colony count, acid producing ability, and the amount of insoluble extracellular polysaccharide synthesis. 1. The irradiation of Nd:YAG laser after photosensitization with Chinese ink inhibited the proliferation of S. mutans the most, and the irradiation of Er:YAG also inhibited the proliferation. However, the irradiation of Nd:YAG laser alone could not inhibited the proliferation of S. mutans. The pulse repetition rate did not affect significantly on the proliferation of bacteria in overall. 2. The irradiation of Nd:YAG laser after the photosensitization with Chinese ink inhibited the acid production of S. mutans the most for a certain period of time. Er:YAG laser also inhibited acid production. When Nd:YAG laser was used alone, the acid production of S. mutans was not been inhibited. The irradiation of Nd:YAG laser after photosensitization with Chinese ink inhibited the acid production ability of bacteria the most as the pulse repetition rate increased. 3. Laser irradiation did not inhibited the synthesis of insoluble extracellular polysaccharide of S. mutans. From these results, we conclude that the irradiation of Er:YAG laser and Nd:YAG laser after photosensitization with Chinese ink would inhibit the proliferation and acid production by S. mutans, which may prevent dental caries. However, this effect does not last long time so that the laser irradiation should be repeated frequently in order to obtain clinical effect; thus, this laser irradiation would not have a clinical usefulness in preventing dental caries when used solely.

  • PDF

Q-Switched Nd YAG's SHG conversion techniques for a skin diseased treatment (피부질환 치료를 위한 Q-Switched Nd:YAG의 SHG 변환기술)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1141-1149
    • /
    • 2009
  • Pulse style Nd: YAG Laser is suitable in skin remaking treatment, in compliance with the ramp continuous oscillation until of course normal takeoff, the Q-switch and mode motive takeoff the takeoff form which is various is possible and it is coming to be widely used in microsurgery and skin remaking promotion. According to therapeutic objective very it is important to control a energy density. Control of energy density the method which controls the pulse repetition rate of Laser output is mainly used. From the research which it sees pulse style Nd: It will be able to control the pulse repetition rate of YAG, the 2nd harmonic occurrence Laser (second harmonic generation: SHG) with the energy part of the light-wave which is a footnote wave number will hold and nonlinear decision it propagates and is converted by energy of the light-wave which is a footnote wave number the actual condition which and it applies the second harmonic occurrence in compliance with a secondary nonlinearity it leads and until skin deep part therapeutic possibility is the thing it will be able to observe simply.