• Title/Summary/Keyword: Repeated Measurement Stability

Search Result 36, Processing Time 0.028 seconds

The Effect of Stability Exercise For Pain Level of Cervical and Lumbar Region, Muscle Volume and Fat Mass Composition in Body of High School in Man volleyball Player (고등학교 남자배구선수들의 안정화운동에 대한 경.요부의 통증수준과 근육량, 체지방에 미치는 영향)

  • Won, Sang-Hee;Jeon, Cha-Sun;Yu, Woung-Sik
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.41-48
    • /
    • 2009
  • Purpose: to program introduction the effects of stability sling exercise and common exercise of high school in man volleyball player. Methods: This study divided the subjects into a sling-exercise group and a common exercise group to compare after practicing exercises twice per week for 8 weeks (total 16 times). To compare the means of the experimental group and the control group on each variable, the ANOVA for repeated measure was used and if there was any significant difference across the measurement times, post-hoc comparisons were conducted for the difference. Results: The T-tests for group difference according to exercise type on each of the variables showed the results as follows. The pain in cervical region is experimental and control groups pain correlation were not significant(p>0.05). But lumbar region experimental and control groups were significant(p<0.05). Muscle volume was increased during 8weeks in experimental and control groups. But experimental and control groups muscle volume correlation were not significant(p>0.05). Conclusion: Fat Mass composition was decreased during 8 weeks in experimental and control groups. But experimental and control groups mass composition correlation were not significant(p>0.05).

  • PDF

THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG (미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과)

  • Cho, Jin-Yong;Kim, Young-Jun;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

Visibility Measurement in an Atmospheric Environment Simulation Chamber

  • Tai, Hongda;Zhuang, Zibo;Jiang, Lihui;Sun, Dongsong
    • Current Optics and Photonics
    • /
    • v.1 no.3
    • /
    • pp.186-195
    • /
    • 2017
  • Obtaining accurate visibility measurements is a common atmospheric optical problem, and of vital significance to civil aviation. To effectively evaluate and improve the accuracy of visibility measurements, an outdoor atmospheric simulation chamber with dimensions of $1.8{\times}1.6{\times}55.7m^3$ was constructed. The simulation chamber could provide a relatively homogeneous haze environment, in which the visibility varied from 10 km to 0.2 km over 5 hours. A baseline-changing visibility measurement system was constructed in the chamber. A mobile platform (receiver) was moved from 5 m to 45 m, stopping every 5 m, to measure and record the transmittance. The total least-squares method was used to fit the extinction coefficient. During the experiment conducted in the chamber, the unit weight variance was as low as $1.33{\times}10^{-4}$ under high-visibility conditions, and the coefficient of determination ($R^2$) was as high as 0.99 under low-visibility conditions, indicating high stability and accuracy of the system used to measure the extinction coefficients and strong consistency between repeated measurements. A Grimm portable aerosol spectrometer (PAS) was used to record the aerosol distribution, and then Mie theory was used to calculate the extinction coefficients. The theoretical results were found to be consistent with the measurements and exhibited a positive correlation, although they were higher than the measured values.

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

A Study on Stability evaluation in the freezing/thawing process of urine specimen analytes (소변 검체 분석물질의 냉/해동 과정 안정성 평가 연구)

  • Kim, Min Kyung;Kim, Sung Wook;Hwang, You Seong;Oh, Eunha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.52-62
    • /
    • 2022
  • The purpose of this study was to find a way to improve the stability and quality of urinalysis by checking the changes in the measurement values of representative clinical chemistry test items according to the repeated freezing and thawing before the urine test and the thawing process. All subjects were 10 healthy males, and the freeze and thaw stability test was performed using their urine samples. In the case of micro-albumin and amylase, there was no statistical significance at 37℃ with time, but at 42℃ and 60℃, there was a statistically significant change in the results with time. There were statistically significant changes in BUN, creatinine, uric acid, and glucose. As a result of long-term stability, after 7 days, glucose mutation increased and amylase decreased at 60℃. In the case of glucose and amylase, there was a statistically significant change in the results over time. To obtain accurate test results, accurate standardization of urinalysis including appropriate collection, storage, and storage methods of urine samples is required and systematic study of conditions for securing stability for each biomaterial is required.

SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT (지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구)

  • Jung Seok-Won;Kim Hee-Jung;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method (압전형 수신 기법을 이용한 초음파 절대변위진폭 측정)

  • Park, Seong-Hyun;Kim, Jongbeom;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.

Comparison of the Immediate Effect of Ankle and Hip Joint Thera-band Exercise on the Balance Ability

  • Cho, Eunnarae;Kwon, Yeong-Seo;Lee, Dongyeop;Hong, Ji-Heon;Yu, Jae-Ho;Kim, Jin-Seop;Kim, Seong-Gil
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.4
    • /
    • pp.23-31
    • /
    • 2021
  • PURPOSE: This study compared the effect of training ankle joint and hip joint thera-band exercise on balance. METHODS: The participants were divided into two groups of 11 each. Group A performed hip exercise after ankle exercise, and Group B performed ankle exercise after hip exercise. Using a green thera-band, the dorsiflexion and plantarflexion and hip flexion and hip extension were exercised repeatedly for 15 seconds three times with a five-second rest between each set. After the exercise and measurement of one area were complete, the exercise and measurement of the other area were performed at one-day intervals. The balance ability was assessed using a Tetrax and Y-balance test and repeated three times; the best values were taken. RESULTS: In the stability index (ST) of the static balance, the hip joint exercise group (HTG) during the follow-up of normal eye open (NO) revealed notable improvement over the ankle joint exercise group (ATG), and in the follow-up of the normal eye closed (NC), the ATG showed significant improvement over the HTG. In the pillow with eye closed (PC) follow-up, the ATG showed significant improvements over the HTG. At the left (Lt) and Y-balance test (YBT), the ATG showed significant improvements in the follow-up over the HTG (p <.05). CONCLUSION: In static balance, the ATG showed significant improvement in the follow-up of NC and PC over the HTG. In the dynamic balance, the Lt. dynamic balance on the non-dominant side in the ATG showed significant improvement in the follow-up over the HTG.

Radiographic Measurement of Ankle Lateral Stability in Normal Korean Adults (정상 한국 성인에서 발목관절 외측 안정성의 방사선학적 계측)

  • Shon, Hyun-Chul;Kim, Yong-Min;Kim, Dong-Soo;Choi, Eui-Sung;Park, Kyoung-Jin;Cho, Byung-Ki;Park, Ji-Kang;Hong, Kyung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.14 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose: Anterior drawer and varus stress test are commonly used for radiologic evaluation of chronic lateral ankle instability. However, there are controversies regarding the method of measurement and the normal value. This study was performed to investigate radiologic normal values in normal Korean adults and to analyze differences by age and gender. Materials and Methods: Sixty Korean adults were recruited and divided in three groups (20 in their twenties, 20 in their thirties, 20 in their forties). There were 10 males and 10 females in each group. The selection criteria were no history of ankle injury and no evidence of instability on physical examination. Radiologic measurement of varus talar tilt and anterior talar translation were performed through anterior and varus stress radiographs using Telos device (150N force). The measurement was repeated twice by three researchers, and intraobserver reproducibility and interobserver reliability were analyzed. The average talar tilt and anterior talar translation were obtained. Results: Talar tilt and anterior talar translation on ankle stress radiographs had good intraobserver reproducibility and interobserver reliability. Talar tilt was average $3.7^{\circ}$ and $5.1^{\circ}$ in male and female of twenties of age, $3.9^{\circ}$ and $4.8^{\circ}$ in their thirties, $3.4^{\circ}$ and $4.5^{\circ}$ in their forties. Anterior talar translation was average 3.5 mm and 4.2 mm in their twenties, 4.1 mm and 3.8 mm in their thirties, 3.6 mm and 4.1 mm in their forties. There was no significant difference in talar tilt and anterior talar translation by age. However, there was significant difference in talar tilt by gender. Conclusion: Normal range of talar tilt angle in Korean adults was below $8.3^{\circ}$, and normal range of anterior talar translation was below 7.6 mm. It seems to be able to serve as a good reference for radiologic evaluation and for treatment of chronic lateral ankle instability.

Improvement of Operating Stabilities in Organic Field-Effect Transistors by Surface Modification on Polymeric Parylene Dielectrics (Parylene 고분자 유전체 표면제어를 통한 OFET의 소자 안정성 향상 연구)

  • Seo, Jungyoon;Oh, Seungteak;Choi, Giheon;Lee, Hwasung
    • Journal of Adhesion and Interface
    • /
    • v.22 no.3
    • /
    • pp.91-97
    • /
    • 2021
  • By introducing an organic interlayer on the Parylene C dielectric surface, the electrical device performances and the operating stabilities of organic field-effect transistors (OFETs) were improved. To achieve this goal, hexamethyldisilazane (HMDS) and octadecyltrichlorosilane (ODTS), as the organic interlayer materials, were used to control the surface energy of the Parylene C dielectrics. For the bare case used with the pristine Parylene C dielectrics, the field-effect mobility (μFET) and threshold voltage (Vth) of dinaphtho[2,3-b:2',3'-f ]thieno[3,2-b]- thiophene (DNTT) FET devices were measured at 0.12 cm2V-1s-1 and - 5.23 V, respectively. On the other hand, the OFET devices with HMDS- and ODTS-modified cases showed the improved μFET values of 0.32 and 0.34 cm2V-1s-1, respectively. More important point is that the μFET and Vth of the DNTT FET device with the ODTS-modified Parylene C dielectric presented the smallest changes during a repeated measurement of 1000 times, implying that it has the most stable operating stability. The results could be meaned that the organic interlayer, especially ODTS, effectively covers the Parylene C dielectric surface with alkyl chains and reduces the charge trapping at the interface region between active layer and dielectric, thereby improving the electrical operating stability.