• 제목/요약/키워드: Repeated Measurement Stability

검색결과 36건 처리시간 0.032초

고등학교 남자배구선수들의 안정화운동에 대한 경.요부의 통증수준과 근육량, 체지방에 미치는 영향 (The Effect of Stability Exercise For Pain Level of Cervical and Lumbar Region, Muscle Volume and Fat Mass Composition in Body of High School in Man volleyball Player)

  • 원상희;전차선;유응식
    • 대한정형도수물리치료학회지
    • /
    • 제15권1호
    • /
    • pp.41-48
    • /
    • 2009
  • Purpose: to program introduction the effects of stability sling exercise and common exercise of high school in man volleyball player. Methods: This study divided the subjects into a sling-exercise group and a common exercise group to compare after practicing exercises twice per week for 8 weeks (total 16 times). To compare the means of the experimental group and the control group on each variable, the ANOVA for repeated measure was used and if there was any significant difference across the measurement times, post-hoc comparisons were conducted for the difference. Results: The T-tests for group difference according to exercise type on each of the variables showed the results as follows. The pain in cervical region is experimental and control groups pain correlation were not significant(p>0.05). But lumbar region experimental and control groups were significant(p<0.05). Muscle volume was increased during 8weeks in experimental and control groups. But experimental and control groups muscle volume correlation were not significant(p>0.05). Conclusion: Fat Mass composition was decreased during 8 weeks in experimental and control groups. But experimental and control groups mass composition correlation were not significant(p>0.05).

  • PDF

미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과 (THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG)

  • 조진용;김영준;유민기;국민석;오희균;박홍주
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권3호
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

Visibility Measurement in an Atmospheric Environment Simulation Chamber

  • Tai, Hongda;Zhuang, Zibo;Jiang, Lihui;Sun, Dongsong
    • Current Optics and Photonics
    • /
    • 제1권3호
    • /
    • pp.186-195
    • /
    • 2017
  • Obtaining accurate visibility measurements is a common atmospheric optical problem, and of vital significance to civil aviation. To effectively evaluate and improve the accuracy of visibility measurements, an outdoor atmospheric simulation chamber with dimensions of $1.8{\times}1.6{\times}55.7m^3$ was constructed. The simulation chamber could provide a relatively homogeneous haze environment, in which the visibility varied from 10 km to 0.2 km over 5 hours. A baseline-changing visibility measurement system was constructed in the chamber. A mobile platform (receiver) was moved from 5 m to 45 m, stopping every 5 m, to measure and record the transmittance. The total least-squares method was used to fit the extinction coefficient. During the experiment conducted in the chamber, the unit weight variance was as low as $1.33{\times}10^{-4}$ under high-visibility conditions, and the coefficient of determination ($R^2$) was as high as 0.99 under low-visibility conditions, indicating high stability and accuracy of the system used to measure the extinction coefficients and strong consistency between repeated measurements. A Grimm portable aerosol spectrometer (PAS) was used to record the aerosol distribution, and then Mie theory was used to calculate the extinction coefficients. The theoretical results were found to be consistent with the measurements and exhibited a positive correlation, although they were higher than the measured values.

무인 원격 방사선 검출 모듈 개발 (Development of Unmanned Remote Radiation Detection Module)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.795-801
    • /
    • 2021
  • 원전 해체 작업장의 요구에 따라 드론 기반 무인 원격 방사선 검출 모듈을 개발하였다. 사람이 접근해서 방사선을 측정할 수 없는 원자력 발전소 격납용기 내부 상공 및 외부로 누설되는 방사선 측정을 위한 목적으로 저준위에 민감한 GM-tube를 사용하여 제작하였다. 드론 기반 방사선 검출 모듈의 무게는 200g 미만으로 원자력 발전소 격납용기 내부의 상공과 외부 공중에서도 운용이 가능하다. 설계된 장비의 성능 확인을 위해 국제 기준 (IEC60864)을 참고하여 성능평가 실험을 시행하였다. 현장의 요구에 맞게 설계된 방사선 검출 모듈의 안정성은 측정 정확도를 평가하기 위한 변동률 실험에서 반복 측정에 의한 통계적 변동률은 ±4.6%. 선량률 의존성을 평가하기 위한 선형성 실험에서 정확도 ± 7.3%, 전체 선형도는 ± 3.5%이며 성능평가를 위한 국제기준을 만족하였다. 본 연구에서 개발한 무인 원격 방사선 검출 모듈은 원전 해체 작업장 맞춤형 장비로, 방사선 분진이 많은 현장에서 정확한 공간선량률의 측정과 방사선 작업장 안전관리에 도움을 줄 수 있을 것으로 확신한다.

소변 검체 분석물질의 냉/해동 과정 안정성 평가 연구 (A Study on Stability evaluation in the freezing/thawing process of urine specimen analytes)

  • 김민경;김성욱;황유성;오은하
    • 한국응용과학기술학회지
    • /
    • 제39권1호
    • /
    • pp.52-62
    • /
    • 2022
  • 소변검사 전 냉/해동 반복과 해동 과정에 따라 대표적인 임상 화학검사 측정값의 변화를 확인함으로써 소변검사의 안정성과 품질 개선방안을 모색하고자 하였다. 조사 대상자는 모두 건강한 남성 10명이었으며 이들의 소변 검체를 이용하여 냉/해동 안정성(freeze and thaw stability) 실험을 진행하였다. Micro-albumin과 Amylase의 경우 시간이 경과 됨에 따라 37℃에서는 통계적 유의성은 없었으나, 42℃와 60℃에서는 시간의 경과에 따른 결과가 통계적으로 유의한 변동이 있었고, BUN, Creatinine, Uric acid와 Glucose에서는 통계적으로 유의한 변동이 있었다. Long term의 안정성 결과, 7일이 지난 후에는 Glucose의 변이는 증가하였고, 60℃에서는 Amylase가 감소하는 양상을 보였다. Glucose와 Amylase의 경우 시간의 경과에 따른 결과가 통계적으로 유의한 변동이 있었다. 신뢰성 있는 검사결과를 얻기 위해서는 소변 시료의 채취, 보관 및 저장 등을 비롯한 요검사의 정확한 표준화가 필요하며 생체 물질별 안정성 확보를 위한 조건들의 체계적 연구가 필요하다.

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

압전형 수신 기법을 이용한 초음파 절대변위진폭 측정 (Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method)

  • 박성현;김종범;장경영
    • 비파괴검사학회지
    • /
    • 제37권1호
    • /
    • pp.7-12
    • /
    • 2017
  • 음향 비선형 파라미터는 입사시킨 기본주파수 성분의 변위 진폭 크기와 재료의 비선형성에 의하여 발생된 2차 고조파 성분의 변위 진폭 크기의 비로 정의된다. 본 연구에서는, 압전소자 방식을 이용한 초음파 절대변위진폭 측정의 타당성을 확인하고자, 이 기법을 통해 초음파가 입사된 SUS316 시편의 절대변위진폭을 측정하였다. 또한 비교를 위해, 레이저를 통한 패브리패럿 방식의 간섭계를 이용하여 동일 시편에 대한 절대변위진폭을 측정하였다. 두 가지 기법을 통한 실험 결과는 서로 잘 일치하는 경향을 보였으며, 특히 압전형 수신 기법의 경우 기존의 레이저 변위측정기법에 비하여 반복 측정의 안정성이 우수한 것으로 나타났다. 이 결과로부터 압전형 수신 기법은 기존 레이저 측정 기법에 비하여 과정이 복잡하지만, 미세변위를 더 안정적으로 측정할 수 있어 음향 비선형 파라미터의 측정에 유리할 것으로 기대된다.

Comparison of the Immediate Effect of Ankle and Hip Joint Thera-band Exercise on the Balance Ability

  • Cho, Eunnarae;Kwon, Yeong-Seo;Lee, Dongyeop;Hong, Ji-Heon;Yu, Jae-Ho;Kim, Jin-Seop;Kim, Seong-Gil
    • 대한물리의학회지
    • /
    • 제16권4호
    • /
    • pp.23-31
    • /
    • 2021
  • PURPOSE: This study compared the effect of training ankle joint and hip joint thera-band exercise on balance. METHODS: The participants were divided into two groups of 11 each. Group A performed hip exercise after ankle exercise, and Group B performed ankle exercise after hip exercise. Using a green thera-band, the dorsiflexion and plantarflexion and hip flexion and hip extension were exercised repeatedly for 15 seconds three times with a five-second rest between each set. After the exercise and measurement of one area were complete, the exercise and measurement of the other area were performed at one-day intervals. The balance ability was assessed using a Tetrax and Y-balance test and repeated three times; the best values were taken. RESULTS: In the stability index (ST) of the static balance, the hip joint exercise group (HTG) during the follow-up of normal eye open (NO) revealed notable improvement over the ankle joint exercise group (ATG), and in the follow-up of the normal eye closed (NC), the ATG showed significant improvement over the HTG. In the pillow with eye closed (PC) follow-up, the ATG showed significant improvements over the HTG. At the left (Lt) and Y-balance test (YBT), the ATG showed significant improvements in the follow-up over the HTG (p <.05). CONCLUSION: In static balance, the ATG showed significant improvement in the follow-up of NC and PC over the HTG. In the dynamic balance, the Lt. dynamic balance on the non-dominant side in the ATG showed significant improvement in the follow-up over the HTG.

정상 한국 성인에서 발목관절 외측 안정성의 방사선학적 계측 (Radiographic Measurement of Ankle Lateral Stability in Normal Korean Adults)

  • 손현철;김용민;김동수;최의성;박경진;조병기;박지강;홍경호
    • 대한족부족관절학회지
    • /
    • 제14권1호
    • /
    • pp.41-46
    • /
    • 2010
  • Purpose: Anterior drawer and varus stress test are commonly used for radiologic evaluation of chronic lateral ankle instability. However, there are controversies regarding the method of measurement and the normal value. This study was performed to investigate radiologic normal values in normal Korean adults and to analyze differences by age and gender. Materials and Methods: Sixty Korean adults were recruited and divided in three groups (20 in their twenties, 20 in their thirties, 20 in their forties). There were 10 males and 10 females in each group. The selection criteria were no history of ankle injury and no evidence of instability on physical examination. Radiologic measurement of varus talar tilt and anterior talar translation were performed through anterior and varus stress radiographs using Telos device (150N force). The measurement was repeated twice by three researchers, and intraobserver reproducibility and interobserver reliability were analyzed. The average talar tilt and anterior talar translation were obtained. Results: Talar tilt and anterior talar translation on ankle stress radiographs had good intraobserver reproducibility and interobserver reliability. Talar tilt was average $3.7^{\circ}$ and $5.1^{\circ}$ in male and female of twenties of age, $3.9^{\circ}$ and $4.8^{\circ}$ in their thirties, $3.4^{\circ}$ and $4.5^{\circ}$ in their forties. Anterior talar translation was average 3.5 mm and 4.2 mm in their twenties, 4.1 mm and 3.8 mm in their thirties, 3.6 mm and 4.1 mm in their forties. There was no significant difference in talar tilt and anterior talar translation by age. However, there was significant difference in talar tilt by gender. Conclusion: Normal range of talar tilt angle in Korean adults was below $8.3^{\circ}$, and normal range of anterior talar translation was below 7.6 mm. It seems to be able to serve as a good reference for radiologic evaluation and for treatment of chronic lateral ankle instability.

Parylene 고분자 유전체 표면제어를 통한 OFET의 소자 안정성 향상 연구 (Improvement of Operating Stabilities in Organic Field-Effect Transistors by Surface Modification on Polymeric Parylene Dielectrics)

  • 서정윤;오승택;최기헌;이화성
    • 접착 및 계면
    • /
    • 제22권3호
    • /
    • pp.91-97
    • /
    • 2021
  • 본 연구는 Parylene C 유전체 표면에 유기 자기조립단분자막(self-assembled monolayer, SAM) 중간층을 도입함으로써 표면특성을 제어하고 최종적으로 유기전계효과 트랜지스터(organic field-effect transistors, OFETs)의 전기적 안정성을 향상시킨 결과를 제시하였다. 유기 중간층을 적용함으로써, Parylene C 게이트 유전체의 표면 에너지를 제어하였으며, OFET의 가장 중요한 성능변수인 전계효과 이동도(field-effect transistor, μFET)와 문턱 전압 (threshold voltage, Vth)의 성능향상과 구동 안정성을 증대시켰다. 단순히 Parylene C 유전체를 적용한 Bare OFET에서 μFET 값은 0.12 cm2V-1s-1가 측정되었으나, hexamethyldisilazane (HMDS)과 octadecyltrichlorosilane (ODTS)를 중간층으로 적용된 소자에서는 각각 0.32과 0.34 cm2V-1s-1로 μFET가 증가하였다. 또한 1000번의 transfer 특성의 반복측정을 통해 ODTS 처리한 OFET의 μFET와 Vth의 변화가 가장 작게 나타남을 확인하였다. 이 연구를 통해 유기 SAM 중간층, 특히 ODTS는 효과적으로 Parylene C 표면을 알킬 사슬로 덮어 극성도를 낮춤과 함께 전하 트래핑을 감소시켜 소자의 전기적 구동 안정성을 증가시킬 수 있음을 확인하였다.