• 제목/요약/키워드: Renewable energy system

검색결과 2,432건 처리시간 0.179초

신.재생에너지 발전전력의 기준가격 산정에 관한 연구 (A Study on the Assessment of Feed-in Tariffs for Renewable Energy Generation)

  • 이창호;조인승;조기선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.733-735
    • /
    • 2005
  • Korea adopted feed-in-tariff system to disseminate the renewable energy generation in 2002, and amended twice this system in October 2003 and October 2004. It is weil known that feed-in-tariff system have been made with noticeable results in Europe countries. In Korea, however, there are many debatable issues about Korea's feed-in-tariff system, such as tariff level, operational period(the term of guarantee). assessment techniques This paper surveys and re-considers several problems and issues which have been discussed during the last two years.

  • PDF

영구자석 동기발전기와 회류수조를 이용한 조류발전 시스템의 특성 해석 (Analysis of the Characteristics of the Tidal Current Power Generation System Using PMSG and Water Tunnel)

  • 안원영;이석현;김근수;이강희;조철희
    • 신재생에너지
    • /
    • 제9권1호
    • /
    • pp.44-50
    • /
    • 2013
  • In order to analyze the characteristics of tidal current power generation system, we measured the output power according to the stream velocity by a water tunnel system and a simulation in MATLAB/Simulink. The water tunnel system consisted of impeller tidal flow transducer and PMSG with rotor in the water. The simulation consisted of PMSG, the tidal current turbine, and back-to-back converter. Also, we simulated the characteristics of output power according to the change of blade length and angular velocity.

선형 프레넬 반사판 태양열 발전시스템의 설계 및 제작 (Design and Manufacture of Linear Fresnel Reflector Solar Thermal System)

  • 김하늘;김종규
    • 융복합기술연구소 논문집
    • /
    • 제8권1호
    • /
    • pp.1-4
    • /
    • 2018
  • In this study, design and manufacture of LFR (Linerar Fresnel Reflector) system was performed for solar thermal absorption cooling. The LFR system was designed considering the expansion and convenience to be installed according to the cooling capacity of the applicable building. Twelve LFR modules with a total reflection area of $204m^2$ were installed. The automatic tracking system was applied to track the sun during the daytime.

신재생발전 확대적용을 위한 ESS와 천연가스발전기의 경제성 평가 (Economic Evaluation of ESS and Natural Gas Generator for Expansion of New and Renewable Generation)

  • 주용진;신주곤;서동균;박세익
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.363-369
    • /
    • 2018
  • This paper considers the alternative way to mitigate cost for REC instead of Photovoltaic (PV) panels with Energy Storage System (ESS). This study starts from an economic analysis of a 1 megawatt PV system without ESS. Several assumptions have been applied in consideration of the current domestic situation. Based on this result, the economic efficiency of PV with ESS improved. However, the reliance on government subsidies was very high. The alternative way to cover the fluctuation power from renewable energy was reviewed with economical and technical way. In case the natural gas engine applied to PV, the IRR and Levelized Cost of Electricity (LCOE) can be improved without ESS. And if small amount of additional REC, the IRR can be improved up to investment level.

저온 폐열을 이용하기 위한 유기랭킨 사이클의 작동유체 선정에 관한 연구 (Selection of Working fluid for the Organic Rankine Cycle to Utilize Low-Temperature Waste Heat)

  • 조수용;조종현
    • 신재생에너지
    • /
    • 제10권4호
    • /
    • pp.36-46
    • /
    • 2014
  • Low-grade heats are wasted even though an amount of their energy is huge. In the small and medium industrial complex sites, large amount of low-grade thermal energy generated during the manufacturing process is wasted if it is not used directly for building heating or air-conditioning. In order to utilize this waste thermal energy more efficiently, organic Rankine cycle (ORC) was adopted. The range of operating temperature of ORC was set to $60^{\circ}C$ from $30^{\circ}C$ applicable low-temperature waste heat. A study was conducted to select an appropriate organic working fluid based on these operating conditions. More than 60 working fluids were screened. Eleven working fluids were selected based on the requirements as working fluid for ORC such as environmentally friendly, safety, and good operation on the expander. Finally, six working fluids were selected by considering the operating temperature ranges. Then, a cycle analysis was conducted with these six working fluids. As a results, R-245fa and R-134a appeared as appropriate working fluids for ORC operating at low-temperature condition based on the system efficiency and the turbine output power.

기후데이터 분석을 통한 태양광모듈의 내구성 평가 기준 제안 (Suggestion of PV Module Test Methods Based on Weathering Monitoring)

  • 김경수;윤재호
    • Current Photovoltaic Research
    • /
    • 제7권2호
    • /
    • pp.46-50
    • /
    • 2019
  • The photovoltaic (PV) system consists of solar cells, solar modules, inverters and peripherals. The related evaluation and certification are proceeding as standards published by the IEC (International Electrotechnical Commission) TC (Technical Committee) 82. In particular, PV module is a component that requires stable durability over 20 years, and evaluation in various external environments is very important. Currently, IEC 61215-based standards are being tested, but temperature, humidity, wind and solar radiation conditions are not considered in all areas. For this reason, various types of defects may occur depending on the installation area of the same photovoltaic module. In particular, the domestic climate (South Korea) is moderate. The various test methods proposed by IEC 61215 are appropriate, excessive, or insufficient, depending on environmental condition. In this paper, we analyze the climate data collection for one year to understand the vulnerability of this test method of PV modules. Through this, we propose a test method for PV module suitable for domestic climatic conditions and also propose a technical consideration for installation and design of PV system.

연료전지 삼중열병합 시스템의 성능개선 R&D 효과에 대한 경제성 분석 연구 (Economic Analysis Study on the R&D Effect of Performance Improvement of the Tri-generation Fuel Cell System)

  • 안종득;이관영;서석호
    • 신재생에너지
    • /
    • 제18권2호
    • /
    • pp.26-39
    • /
    • 2022
  • Considering the recent substantial increase in national research and development (R&D) budgets in the energy sector there has been increased Interest in the effectiveness of government R&D investments. We conducted a case study to calculate the allowable scale and effectiveness of R&D investment by calculating the direct performance improvement effect resulting from R&D investment as an economic value. Using conditions that existed prior to R&D investments as a reference, five cases in which performance improved due to R&D investments were compared and analyzed. The government's financial investment is increasing rapidly in line with the establishment of the national hydrogen roadmap. R&D is needed to enhance the current low technology readiness level of hydrogen fuel cells compared to solar and wind energy fields. Therefore, an R&D project to improve the performance of the fuel cell system was selected as this case study's subject. Using the results in this study, the allowable level of investment in the task unit of national R&D projects could be calculated. Moreover, it is advisable to provide a standard for rational decision making for new R&D investments since it is possible to determine investment priorities among a large number of candidates.

신재생 에너지 최적 활용을 위한 축열조 온도 예측 모델 연구 (A Study on the Thermal Prediction Model cf the Heat Storage Tank for the Optimal Use of Renewable Energy)

  • 오한별;장경민;오지영;이명배;박장우;조용윤;신창선
    • 스마트미디어저널
    • /
    • 제12권10호
    • /
    • pp.63-70
    • /
    • 2023
  • 최근 스마트팜 에너지 비용 중 35% 낸난방비 에너지 소비가 증가되어 에너지 소비 효율화가 요구되며, 전기료 현실화에 대한 우려로 신재생 에너지 중요성이 증가하고 있다. 신재생 에너지는 수력, 풍력, 태양광 등에 속하며, 이중 태양광 에너지는 전기에너지로 변환하는 발전기술로, 이 기술은 에너지원이 환경에 미치는 영향이 적고, 유지 보수가 간편하다는 특징을 갖고 있다. 본 연구에서는 온실 축열조, 히트펌프 데이터 기반으로 축열조 영향을 많이 미치는 요소를 선정하고 축열조 공급 온도예측 모델을 개발하고자 한다. 시계열 데이터 분석 및 예측에 효과적인 LSTM(Long Short-Term Memory)과 다른 앙상블 학습 기법보다 뛰어난 XGBoost 모델을 이용하여 예측한다. 히트펌프 축열조 온도를 예측함으로써 에너지 소비를 최적화하여 시스템 운영을 최적화할 수 있다. 또한, 태양광 활용에 따른 냉난방비 절감 및 농가의 에너지 자립도 개선 등 스마트팜 에너지 통합 운영 시스템에 연계하고자 한다. 플랫폼을 통해 폐열 에너지의 공급을 관리하고 최대 난방부하 및 계절, 시간별 작물생장에 필요한 에너지값을 도출하여 이를 기반으로 최적 에너지 운용방안을 도출하고자 한다.

Active and Reactive Power Control of ESS in Distribution System for Improvement of Power Smoothing Control

  • Shin, Seong-Su;Oh, Joon-Seok;Jang, Su-Hyeong;Cha, Jae-Hun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1007-1015
    • /
    • 2017
  • This paper proposes a new control technique of energy storage system (ESS) for smoothing the active power of renewable energy sources (RES) such as photovoltaic and wind turbine generation. As the penetration of RES into grid increases, it is difficult to maintain the permissible level of power quality, that is, voltage and frequency fluctuation in power systems. To solve this problem, ESS control methods using low pass filter (LPF) have been proposed for mitigating the fluctuation of RES output. However, those have a lot of drawbacks which need to be supplemented. Hence, this paper presents the improved active power control with additional reactive power control for maintaining power quality properly. The proposed method minimizes the capacity of ESS to be required for smoothing RES output fluctuation through mitigation of phase delay problem in LPF. In addition, the voltage regulation improves by using additional reactive power control. The proposed method was verified through simulation analysis using PSCAD/EMTDC.

가파도 마이크로그리드 신재생 에너지 전원 구성 방안 (Renewable Energy Configuration Plan of Micro Grid in Gapa Island)

  • 김동완;고지한;김승현;김호민;김일환
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.16-23
    • /
    • 2014
  • This paper presents a renewable energy configuration plan of Micro grid in Gapa Island. To analyze the characteristics of Micro grid, BESS (Battery Energy Storage System), PMSG (Permanent Magnet Synchronous Generator) and SCIG (Squirrel Cage Induction Generator) are first modelled. The PMSG and SCIG will operate with basis on the real power curve. when the total power demand is larger than the total power generation, the BESS will be operated and the SOC (State Of Charge) is reduced. If the value of SOC could drop down to limited value, the system may be broken because of the voltage drop of BESS. To solve this problem, a DG (Diesel Generator) is used to charge the BESS and keep the voltage value of BESS with in a allowance limit. This paper represents simulation result when PMSG, SCIG connected to the Micro grid installed in Gapa Island. The simulation is carry out by using PSCAD/EMTDC program with actual line constant and transformer parameter in Gapa Island.