• Title/Summary/Keyword: Remover

Search Result 78, Processing Time 0.025 seconds

Development of a Water-Spraying Type Automatic Glochids Removal System for Cactus (Opuntia humifusa) Stem

  • Jang, Ik Joo;Park, Tusan;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.3
    • /
    • pp.201-207
    • /
    • 2016
  • Purpose: A water-spraying type automatic glochids removal system for cactus (Opuntia humifusa) stem was developed, and its performance was evaluated. The system was developed to reduce intensive human labor in removing glochids from cactus stem skin without inducing damage prior to further processing into value-added products. Methods: The developed system consists of conveyor and water-spraying systems. The conveyor system delivers cactus stems through water-spraying compartments and finally to a collecting box. In order to remove the glochids, rotating nozzles spray water over all areas (i.e., front and back faces and sides) of the cactus skin under controlled water pressure. Operating conditions such as conveyor speed, water pressure, angle of water-spraying nozzles, distance between conveyor belt and rotating nozzles, and angle of cactus flipping slide were adopted from our previous study and applied on the system design and manufacturing. The performance of glochids removal was evaluated by counting the number of glochids on the cactus stem before and after processing on the system. Results: The developed system performed efficiently and effectively under the pre-studied operating conditions except for the angle of cactus flipping slide. The new system had a glochids removal ratio of 94.1% without damaging the cactus skin. Considering the original number (approximately 30-60) of glochids, the remaining number was low (1-4), and most of them were found at the side edge of the cactus stem. This system can remove glochids from 360 cactus stems in 1 hr regardless of cactus size. Conclusions: The performance of the new system in glochids removal without damaging cactus skin is superior to any other existing device (i.e., brush type, rubber-friction type, and agitation type). The system is expected to be applied in cactus (O. humifusa) processing facilities.

Program for Estimating Service Time for Oxygen Generating Closed-Circuit SCBA -Pilot Study- (산소발생 폐쇄식 SCBA의 서비스 수명 예측 프로그램 -예비연구-)

  • Han, Don-Hee;Kim, Dong Cheon;Kang, Min Sun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.120-130
    • /
    • 2007
  • A oxygen generating closed-circuit SCBA for escape from fire will be newly developed and then a program for estimating service time for it should be required. A SCBA made on an experimental basis consisted of five components such as half facepiece (mask), $KO_2$ box, oxygen reservoir, $CO_2$ remover and hood. The half mask had a good fitting performance since fit factors for 10 subjects were all above 100. It was found that height of subjects should be the best variable to estimate service time. Measured service time was inversely correlated with height of subjects. Service life time could be estimated by interpolation and extrapolation using inverse relationship between height and measured service time, for example, 28 minutes for male and female of 170 cm during resting, 10 minutes at the walk of 4 km/h and 5 minutes at the walk of 6 km/h considering safety margin of 20%. The study implies that program for estimating service time for the SCBA should require subject's height, speed of walk (4 km/h and 6 km/h) and fit testing. Considering safety margin, selecting younger subjects would be better. The study on the number of subjects and selecting facial dimensions should be more needed for the final program.

An Analysis of Design Factors for Developing Opuntia Humifusa Spines Removal Device

  • Jang, Ik Joo;Ha, Yu Shin
    • Journal of Biosystems Engineering
    • /
    • v.38 no.3
    • /
    • pp.215-221
    • /
    • 2013
  • Purpose: Opuntia Humifusa has been used in the food and beauty industry after removing spines and glochids clearly. This study compared the methods used in removing spines and analyzed the design factors for developing a spine removal device. Method: This study compared the spine removal ratios in accordance with the length of brush, water spray pressure, the number of water spray, and the size of Opuntia Humifusa in a rotating brush device and a water spray device. In addition, this study compared the reversal ratios according to the inclination angle of a conveyor, the drop height of Opuntia Humifusa, and the speed of the conveyor to analyze the reversal factors. Results: The spines were not removed clearly in the rotating brush method, and the glochids were nailed deeply. The spine removal ratio was 96.9% with the water spray pressure of 20 $kgf/cm^2$ and the conveyor speed of 10 cm/s in the water spray method. The number of water spray was correlated with the spine removal ratio, and the average spine removal ratio was 95.6% with three cycles of water spray. The reversal ratio was 97% with the inclination angle of the conveyor $20^{\circ}$, the drop height of 380 mm, and the conveyor speed of 10 cm/s. Conclusions: In order to develop a Opuntia humifusa spine removing device, this study compared the rotating brush and water spray methods. As a result, each spine removal performance of the rotating brush and water spray methods was 96.9% and 95.6%, respectively. Although the performance of the rotating brush method was slightly higher than that of the water spray method, the water spray method was suitable for removing spines from stem because the epidermis of stem was damaged and the glochids were nail deeply in the rotating brush method. Further studies on appropriate arrangement of spray nozzles, maintaining the optimal water spray pressure, the speed and angle control of the feeding conveyor, and devices for inducing the stem to the center will be needed in combining the water spray device and the reversal device.

An Investigation of Eye Inconvenience due to the Wearing and Management of Lens of Female University Students (여대생의 렌즈 착용과 관리 행위에 따른 눈의 불편감 조사)

  • Jang, Hyun-Jung;Jeon, Hye Won
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.183-190
    • /
    • 2020
  • This study was designed to investigate the current state of lens wearing and care, and to investigate eye discomfort according to the care method. Data of 209 female college students wearing lenses for more than 1 year were analyzed using the SPSS / WIN 22.0 program. 40.2% of female students wear lenses every day and 97.1% wear all day. However, only 45.4% of students washed it daily, and only 17.7 % used protein remover during wash, which resulted in poor management. 98.1% of students complained of discomfort due to the lens, and the Ocular Surface Index (OSDI) scored 42.88 ± 15.25, which was classified as a severe dry eye and threatened eye health. Therefore, it is necessary to improve students' awareness of lens management, and periodical lens inspection and management education are needed.

An Experimental Study of Water Vapor Pressure Change by Ambient Temperature at the Interface between Concrete and Fluid-Applied Membrane Layer

  • Ko, Jin-Soo;Kim, Byung-Yun;Park, Sung-Woo;Lee, Mun-Hwan;Lee, Sung-Bok
    • International Journal of Concrete Structures and Materials
    • /
    • v.3 no.1
    • /
    • pp.15-23
    • /
    • 2009
  • Over about 30% of problems in construction is related to water-leaking, and the loss from this problem can incur as much as three times the cost of initial construction. Thus, water vapor pressure is known to be the primary cause of defective waterproofing. Accordingly, the theories on the relationship between water pressure and temperature as well as damp-proofing volume of concrete and the change in vapor pressure volume were reviewed and analyzed in this study by making test samples after spraying a dampness remover and applying waterproofing materials to the prepared test specimens. The result of measuring water vapor pressure with the surface temperature of the waterproofing (fluid-applied membrane) layer at the experimental temperature setting of about $10^{\circ}C$, which is the annual average temperature of Seoul, indicated that (1) the temperature of the fluid-applied membrane elevated to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about 0.03 N/mm 2 when the surface temperature of the waterproofing layer was raised to about $80^{\circ}C$. (2) when the temperature of the fluid-applied membrane of the waterproofing layer was raised from $30^{\circ}C$ to $35^{\circ}C$, water vapor pressure of about 0.01 N/mm 2 was generated, and (3) when a thermal source was applied to the fluid-applied membrane (waterproofing) layer, the temperature increased from $35^{\circ}C$ to $40^{\circ}C$, and approximately $0.005\;N/mm^2$ of water vapor pressure was generated.

An Experimental Study of Water Vapor Pressure that occurs at the Interface of a Fluid-Applied Membrane and Concrete (콘크리트와 도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구)

  • Ko, Jin-Soo;Kim, Mun-Hee;Lee, Sung-Bok;Shin, Yun-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.147-150
    • /
    • 2006
  • Of the total defects that have occurred recently in the Korean construction market, over 30% are caused by the construction of defective waterproofing, and the phenomenon of air pockets in the waterproofing layer, which is caused by the concrete vapor pressure, is known to be the primary cause of defective waterproofing. Accordingly, in this study the theory about the relationship between water pressure and temperature as well as the damp-proofing volume of concrete and, then, the change of vapor pressure volume was measured and analyzed by making a test sample after spraying a dampness remover and a waterproofing material to a prepared test body. As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about $10^{\circ}C$, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about $0.3kgf/cm^2$ when the surface temperature of the waterproofing layer was raised up to about $80^{\circ}C$. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from $30^{\circ}C\;to\;35^{\circ}C,\;about\;0.1kgf/cm^2$ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from $35^{\circ}C\;to\;40^{\circ}C$, approximately $0.05kgf/cm^2$ of water vapor pressure was generated.

  • PDF

A Study on Repair Method of Concrete Structures using the Solution of Removing Chloride (염분제거용 약액을 이용한 콘크리트 구조물의 보수공법에 관한 연구)

  • Kim, Woonhak;Hwang, Sungwoon;Kang, Seokwon
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.562-569
    • /
    • 2017
  • Reinforced concrete is used for bridges and large structures that are constructed with social overhead capital because they are economically and semi-permanently integrated with reinforcing bar and concrete. However, when the chloride ion in the concrete destroys the passive film of the reinforcing bar by the marine exposure environment and the snow remover used in the winter season, and the reinforcing bar is corroded by various chemical and physical actions, the durability is deteriorated in a short period, and the life span is shortened. In this study, a repair method to recover the durability of the initial structure by effectively removing chloride ion from the damage caused by salting of the above mentioned reinforced concrete was conducted.

A Study on Portable Green-algae Remover Device based on Arduino and OpenCV using Do Sensor and Raspberry Pi Camera (DO 센서와 라즈베리파이 카메라를 활용한 아두이노와 OpenCV기반의 이동식 녹조제거장치에 관한 연구)

  • Kim, Min-Seop;Kim, Ye-Ji;Im, Ye-Eun;Hwang, You-Seong;Baek, Soo-Whang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.679-686
    • /
    • 2022
  • In this paper, we implemented an algae removal device that recognizes and removes algae existing in water using Raspberry Pi camera and DO (Dissolved Oxygen) sensor. The Raspberry Pi board recognizes the color of green algae by converting the RGB values obtained from the camera into HSV. Through this, the location of the algae is identified and when the amount of dissolved oxygen's decrease at the location is more than the reference value using the DO sensor, the algae removal device is driven to spray the algae removal solution. Raspberry Pi's camera uses OpenCV, and the motor movement is controlled according to the output value of the DO sensor and the result of the camera's green algae recognition. Algae recognition and spraying of algae removal solution were implemented through Arduino and Raspberry Pi, and the feasibility of the proposed portable algae removal device was verified through experiments.

Arsenic Removal Mechanism of the Residual Slag Generated after the Mineral Carbonation Process in Aqueous System (광물탄산화 공정 이후 발생하는 잔사슬래그의 수계 내 비소 제거 기작)

  • Kim, Kyeongtae;Latief, Ilham Abdul;Kim, Danu;Kim, Seonhee;Lee, Minhee
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.377-388
    • /
    • 2022
  • Laboratory-scale experiments were performed to identify the As removal mechanism of the residual slag generated after the mineral carbonation process. The residual slags were manufactured from the steelmaking slag (blast oxygen furnace slag: BOF) through direct and indirect carbonation process. RDBOF (residual BOF after the direct carbonation) and RIBOF (residual BOF after the indirect carbonation) showed different physicochemical-structural characteristics compared with raw BOF such as chemical-mineralogical properties, the pH level of leachate and forming micropores on the surface of the slag. In batch experiment, 0.1 g of residual slag was added to 10 mL of As-solution (initial concentration: 203.6 mg/L) titrated at various pH levels. The RDBOF showed 99.3% of As removal efficiency at initial pH 1, while it sharply decreased with the increase of initial pH. As the initial pH of solution decreased, the dissolution of carbonate minerals covering the surface was accelerated, increasing the exposed area of Fe-oxide and promoting the adsorption of As-oxyanions on the RDBOF surface. Whereas, the As removal efficiency of RIBOF increased with the increase of initial pH levels, and it reached up to 70% at initial pH 10. Considering the PZC (point of zero charge) of the RIBOF (pH 4.5), it was hardly expected that the electrical adsorption of As-oxyanion on surface of the RIBOF at initial pH of 4-10. Nevertheless it was observed that As-oxyanion was linked to the Fe-oxide on the RIBOF surface by the cation bridge effect of divalent cations such as Ca2+, Mn2+, and Fe2+. The surface of RIBOF became stronger negatively charged, the cation bridge effect was more strictly enforced, and more As can be fixed on the RIBOF surface. However, the Ca-products start to precipitate on the surface at pH 10-11 or higher and they even prevent the surface adsorption of As-oxyanion by Fe-oxide. The TCLP test was performed to evaluate the stability of As fixed on the surface of the residual slag after the batch experiment. Results supported that RDBOF and RIBOF firmly fixed As over the wide pH levels, by considering their As desorption rate of less than 2%. From the results of this study, it was proved that both residual slags can be used as an eco-friendly and low-cost As remover with high As removal efficiency and high stability and they also overcome the pH increase in solution, which is the disadvantage of existing steelmaking slag as an As remover.

Removal Methods of Paint Pollutants on the Stone Cultural Heritage using Poultices (습포제를 이용한 석조문화재의 페인트 오염물 제거기법 연구)

  • Lee, Joo-Wan;Ham, Chul-Hee;Kim, Sa-Dug;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.25 no.4
    • /
    • pp.421-430
    • /
    • 2009
  • This research was carried out focusing on the urgent treatment and related studies for paint scribbling on Samjeondobi Monument (Historic Sites No. 101) in 2007. Before the preliminary test, the paint lacquer used on the surface of Samjeondobi Monument was analyzed. The paint lacquer turned out to be the paint lacquer spray composed of $Pb_3O_4$ used for the red pigment in the market. It was proved that the poultice used with the organic solvent was the best way to remove the paint pollutants following the preliminary test for the removal of paint pollutants which was performed with various removal methods by the laser, etc. However, the removing the paint pollutants was found in difficulty in contrast to the preliminary tests because the paint on the spot was hardened so rapidly over time that there was difference from the situation of the laboratory. For that problem, the poultice method with ethylene dichloride of main component from Remover (goods in the market) was the most efficient, therefore the pollutants were removed with the solution of alkyds resin and nitrocellulose and the rest part was removed by the $Laponite^{(R)}$ RD.

  • PDF