Browse > Article

Program for Estimating Service Time for Oxygen Generating Closed-Circuit SCBA -Pilot Study-  

Han, Don-Hee (Department of Occupational Health and Safety Engineering / Institute of Biomedical Engineering, Inje University)
Kim, Dong Cheon (Department of Occupational Health and Safety Engineering / Institute of Biomedical Engineering, Inje University)
Kang, Min Sun (Department of Occupational Health and Safety Engineering / Institute of Biomedical Engineering, Inje University)
Publication Information
Journal of Korean Society of Occupational and Environmental Hygiene / v.17, no.2, 2007 , pp. 120-130 More about this Journal
Abstract
A oxygen generating closed-circuit SCBA for escape from fire will be newly developed and then a program for estimating service time for it should be required. A SCBA made on an experimental basis consisted of five components such as half facepiece (mask), $KO_2$ box, oxygen reservoir, $CO_2$ remover and hood. The half mask had a good fitting performance since fit factors for 10 subjects were all above 100. It was found that height of subjects should be the best variable to estimate service time. Measured service time was inversely correlated with height of subjects. Service life time could be estimated by interpolation and extrapolation using inverse relationship between height and measured service time, for example, 28 minutes for male and female of 170 cm during resting, 10 minutes at the walk of 4 km/h and 5 minutes at the walk of 6 km/h considering safety margin of 20%. The study implies that program for estimating service time for the SCBA should require subject's height, speed of walk (4 km/h and 6 km/h) and fit testing. Considering safety margin, selecting younger subjects would be better. The study on the number of subjects and selecting facial dimensions should be more needed for the final program.
Keywords
Service time; Oygen generating closed-circuit SCBA; $KO_2$;
Citations & Related Records
연도 인용수 순위
  • Reference
1 한돈희, Willeke K. : 호흡기보호구 착용시 움직임과 매일 착 용에 따른 Fit Factors 의 변화, 한국산업위생학회지, 6(2), 1996, 176-186
2 OSHAct. 29CFR (Code of Federal Regulations) 'Respiratory Protection' Title 29, Part 1910.134; 2003
3 김정진. 생리학. 고문사; 1984.(103-109쪽)
4 American Industrial Hygiene Association (AIHA). Respiratory Protection -A Manual and Guidance-, 3rd ed. AIHA Respiratory Protection Committee; 2001.p.71-4
5 National Institute for Occupational Safety and Health (NIOSH). Guide to Industrial Respiratory Protection (DHHS/NIOSH Pub. No. 87-116). Washington, D.C., Government Printing Office; 1987.p.54-83
6 노동부. 산업보건기준에 관한 규칙. 노동부. 노동부령 제259 호(2006.9.25);2006