• 제목/요약/키워드: Removal torque values

검색결과 65건 처리시간 0.028초

임플란트 직경이 골유착에 미치는 영향에 관한 연구 (INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS)

  • 이준호;신상완;권상호
    • 대한치과보철학회지
    • /
    • 제41권2호
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

단일, 이중 산처리 임플란트의 회전제거력 비교 (Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias)

  • 김종진;조성암
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.335-341
    • /
    • 2019
  • 목적:불산과 염산/ 황산을 두 번 사용하는 임플란트 표면처리 방식은 선반가공한 표면에 비하여 강한 결합력을 보이지만 두 번 산처리하는 방식은 티타늄의 피로도를 야기시켜 미소균열을 야기시킬 수 있으므로, 염산으로 한번 산처리하는 방식이 비슷한 결합력을 가진다면 단순하고 효율적인 산처리 방식이 될 수 있다. 재료 및 방법: 9개의 지름 3.75, 길이 4 mm의 두 번 처리 방식의 임플란트와 같은 크기의 한 번 처리 방식의 임플란트를 토끼의 경골에 심어서, 10일 후에 회전제거력, 거칠기, 젖음각도를 측정하였다. 결과: 두 번 처리 방식과 한 번 처리 방식의 회전제거력은 차이가 없었고 (P = .995). 두 번 처리군의 거칠기는 $0.93{\mu}m$, 한 번 처리는 $0.84{\mu}m$이었다 (P = .170). 평균젖음각은 두 번 처리는 $99^{\circ}$, 한 번 처리는 $98^{\circ}$ 이었다 (P = .829). 각 변수 모두 두 그룹의 차이는 없었다. 결론:산으로 한번 처리하거나 두 번 처리 하거나 두 그룹의 회전제거력, 거칠기, 평균젖음각의 차이는 없었기 때문에 종래의 dual acid treatment보다 한번 처리하여도 유용한 것으로 보여진다.

Comparison of removal torques between laser-treated and SLA-treated implant surfaces in rabbit tibiae

  • Kang, Nam-Seok;Li, Lin-Jie;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.302-308
    • /
    • 2014
  • PURPOSE. The purpose of this study was to compare removal torques and surface topography between laser treated and sandblasted, large-grit, acid-etched (SLA) treated implants. MATERIALS AND METHODS. Laser-treated implants (experimental group) and SLA-treated implants (control group) 8 mm in length and 3.4 mm in diameter were inserted into both sides of the tibiae of 12 rabbits. Surface analysis was accomplished using a field emission scanning electron microscope (FE-SEM; Hitachi S-4800; Japan) under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Surface components were analyzed using energy dispersive spectroscopy (EDS). Rabbits were sacrificed after a 6-week healing period. The removal torque was measured using the MGT-12 digital torque meter (Mark-10 Co., Copiague, NY, USA). RESULTS. In the experimental group, the surface analysis showed uniform porous structures under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Pore sizes in the experimental group were 20-40 mm and consisted of numerous small pores, whereas pore sizes in the control group were 0.5-2.0 mm. EDS analysis showed no significant difference between the two groups. The mean removal torque in the laser-treated and the SLA-treated implant groups were 79.4 Ncm (SD = 20.4; range 34.6-104.3 Ncm) and 52.7 Ncm (SD = 17.2; range 18.7-73.8 Ncm), respectively. The removal torque in the laser-treated surface implant group was significantly higher than that in the control group (P=.004). CONCLUSION. In this study, removal torque values were significantly higher for laser-treated surface implants than for SLA-treated surface implants.

지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구 (Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments)

  • 이미순;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.164-173
    • /
    • 2009
  • 연구 목적: 심미적 장점을 지닌 지르코니아 지대주와 금속 지대주 사이에 반복 하중 전, 후의 풀림 회전력을 비교하여 지대주 재질에 따른 나사 안정성에 차이가 있는지를 비교 분석해 보고자 하는 것이다. 연구 재료 및 방법: 실험군은 크게 외측 연결 구조(US II, Osstem Implant, Korea)와 내측 연결 구조(GS II, Osstem Implant, Korea)의 임플란트 시스템을 두 군으로 나누었다. 각각의 군에서 지르코니아 지대주군와 금속 지대주군으로 나누어 실험하였다. 각군당5개씩의 시편을 제작하였다. 임플란트 고정체를 별도 제작된 지그에 고정시킨다. 디지털 토크게이지를 이용하여 30 Ncm의 조임 회전력을 가하고 10분 후 동일 조임 회전력을 한번 더 적용하였다. 다음 각 지대주 나사의 초기 풀림 회전력을 디지털 토크게이지로 측정하였다. 동일 시편을 다시 30 Ncm의 조임 회전력을 가하여 체결한 후, 유압식 동적 재료시험기(Instron, USA)에 임플란트 매식체를 치과용 임플란트 피로시험에 관한 ISO/FPIS 14801:2003(E)규정을 참고하여 고정시켰다. 최소 하중은 10 N, 최대 하중은 250 N의 sine형 반복 하중을 $30^{\circ}$의 경사각도로, 하중 주기는 14 Hz로, 100만 회의 반복 하중을 적용한 후 풀림 회전력을 측정하였다. 결과: 1. 모든 시스템에서 지대주 나사의 풀림 회전력이 조임 회전력 보다 감소하였으나, 나사 풀림 현상은 나타나지 않았다. 2. 반복 하중 전과 후의 나사 풀림 회전력은 두 임플란트 시스템 모두에서 지르코니아 지대주가 금속 지대주보다 더 컸다(P<.05). 3. 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 모두에서 지르코니아 지대주와 금속 지대주가 차이가 없는 것으로 나타났다(P>.05). 4. 금속 지대주에서 반복 하중에 따른 풀림 회전력 상실률은 내측 연결 형태의 GS II 시스템이 외측 연결형태의 US II 시스템보다 작았다(P<.05). 5. 지르코니아 지대주에서는 반복 하중에 따른 풀림 회전력 상실률은 두 임플란트 시스템 간에 차이가 없는 것으로 나타났다(P>.05). 결론: 본 실험을 통해 100만회 반복 하중 하에서 지르코니아 지대주가 금속 지대주에 비해 나사 결합부 안정성이 더 크다는 결론을 내릴 수 있다.

교정용 미니스크류 임플랜트의 제거회전력 및 골형성에 관한 연굴 (REMOVAL TORQUE AND BONE FORMATION OF ORTHODONTIC MINISCREW IMPLANT)

  • 윤영국;류재준;서규원
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.492-505
    • /
    • 2007
  • Statement of problem: An orthodontic miniscrew implant has been used as a skeletal anchorage for orthodontic treatment. However, any relation among the influence of the cortical bone, morphologic differences of orthodontic miniscrew implants and new bone formation hasn't been made clear yet. Purpose: The purpose of this study was to evaluate whether the orthodontic miniscrew implant could work as an intraoral skeletal anchorage immediately and stably for orthodontic treatment after insertion of it. Material and methods: Two types of orthodontic miniscrew implants were used in this experiment; tapered type and straight type. One hundred and sixty eight orthodontic miniscrew implants were inserted into the tibiae of 21 rabbits and sacrificed on 3, 7, 11, 14, 21 and 28days later after insertion of them to study removal torque values and histologic and histomorphometric analyses. Results: The results were as follows. 1. The removal torque values of the tapered type were higher than those of the straight type in all groups(p<0.05). 2. There wasn't any distinguishing differences between the tapered type and the straight type about the new bone formation percentage. 3. The removal torque values for both the tapered type and the straight type were gradually decreased at early stages of the test but started to increase at the 7 days group of the straight type and the 11 days group of the tapered type. 4. New bone formation percentage was increased gradually for both the tapered and the straight types as time passed(p<0.05). 5. It was found that the tapered type showed lower values in the cortical bone about both the maximum equilibratory stress distribution and the maximum principal stress distribution than the straight type in linear finite elements analysis. Conclusion: According to the research, the removal torque values were decreased at 7 days group of the tapered type and 11 days group of the straight type after the insertion of the orthodontic miniscrew implants in tibiae of rabbits. Considering the human bone activity, it is better to apply the orthodontic force $3{\sim}4$ weeks later than to apply it immediately after the insertion of orthodontic miniscrew implants. Considering that general orthodontic force is about $250{\sim}500$ grams, the tapered type can be worked as a stable skeletal anchor age in an orthodontic treatment even if the orthodontic force is applied on it immediately after the insertion of it.

Correlation between microleakage and screw loosening at implant-abutment connection

  • Sahin, Cem;Ayyildiz, Simel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.35-38
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS. Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titanium) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (${\alpha}=0.05$). RESULTS. Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION. Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.

REMOVAL TORQUE OF BICORTICALLY STABILIZED RBM(RESORBABLE BLAST MEDIA) PIN IMPLANTS IN RABBIT TIBIA

  • Kim, Kwon-Sik;Suh, Kyu-Won;Lee, Richard Sung-Bok;Ryu, Jae-Jun
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.722-733
    • /
    • 2006
  • Statement of problem. The use of small diameter implants having less than 3 mm in diameter were restricted because of lack of bonding strength to bone. Purpose. The purpose of this study was to observe how much resorbable blast media pin implants increase the binding force to the bone compared to machined transitional pin implants by measuring removal torque, and whether they can be used as final implants for replacement of small diameter teeth. Material and method. Fifteen rabbits were used in this study. Two kinds of implants (resorbable blast media pin implants and machined transitional pin implants) were inserted in each tibia bicortically. After healing time of 2, 4 and 8 weeks, the removal torque values were recorded and the rabbits were sacrificed for histological analysis. Linear finite element method analyses were conducted to compare bicortical fixation with monocortical fixation. Result and conclusion. Within the limitation of this in vivo study, the following conclusions were drawn: 1) The removal torque value of RBM pin implants showed statistically significant increase compared to machined pin implants at 2, 4, and 8 weeks respectively (p<0.05). 2) The removal torque value of RBM pin implants at 2, 4, and 8 weeks was increased statistically significantly with time (p<0.05). 3) Bicortical fixation showed better stress distribution compared with monocortical fixation in a linear finite element method analysis. 4) RBM pin implants are not recommended as transitional implants because they showed a lot of bone fracture in histologic specimens.

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권6호
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

A Study of mechanical properties of oxide layer removed Co-Cr-Mo abutments

  • Ryu, Jae-ho;Huh, Jung-Bo;Ro, Jung-Hoon;Yun, Mi-Jung;Jeong, Chang-Mo
    • 대한치과의사협회지
    • /
    • 제53권11호
    • /
    • pp.804-816
    • /
    • 2015
  • PURPOSE: The aim of this study was to evaluate the influence of the oxide layer removal process in the Co-Cr-Mo (CCM) abutment after casting procedure on the prosthesis settlement and screw stability. MATERIALS AND METHODS: CCM abutments of four different interface conditions (CCM-M; machined, CCM-O; oxide layer formed, CCM-B; blasted, CCM-P; polished after blasted) and gold abutment (Gold-C; Cast with type III Gold alloy) were used. The initial settling values of abutments were evaluated according to the difference of implant-abutment length when the tightening torques were applied at 5 Ncm and 30 Ncm, and the settling values of abutments caused by loading were evaluated according to the difference of implant-abutment length before and after loading with 250 N, 100000 cycle. The loss ratios of removal torque for abutment screws were evaluated according to the difference in value of removal torques under 30 Ncm tightening torque applied before and after cyclic loading. RESULTS: The CCM-P and CCM-B group showed a higher initial settling value compared with the Gold-C group (P<.05), while the Gold-C group showed the highest settling values caused by loading (P<.05) and no significant differences were observed for between CCM groups (P>.05). The loss ratio of removal torque values for the CCM-B, CCM-P groups did not differ significantly from that of the Gold-C group (P>.05). CONCLUSION: Even though the oxide layer was removed by different methods, CCM abutment with internal conical connection structure showed lower abutment settling and similar screw loosening after cyclic loading compared with gold abutment.

Bone Response to Anodized Titanium Implants in Rabbits

  • Lee, Jae-Hyun;Lee, Cheol-Won;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 2011
  • Purpose: The quality of implant surface is one of the factors that influence wound healing of implant site and subsequently affect osseointegration. The objective of modification of the surface properties of an implant is to affect the biological consequence. The purpose of this study is to evaluate the biologic response of osseous tissue to anodized implants. Materials and Methods: Two machined titanium implants for control group were installed in a tibia of each rabbit and two anodized implants for test group were installed in the other tibia of each rabbit. At the moment the implants were installed, resonance frequency analysis (RFA) values were measured. After healing periods of 1, 2, 3, and 7 weeks, the implants were uncovered and RFA values were measured again. Removal torque was measured for one implant in the test group and one implant in the control group. Histological evaluation was executed in the other implants. Results: Both of test group and control group have the tendency of greater RFA change rate and removal torque value as healing periods became longer, but were statistically insignificant (P>0.05). However, in the case of the same healing period, the test group tended to have greater RFA change rate and removal torque than the control group (P<0.05). More active new bone formation from endosteal surface was noted on the anodized surface than machined surface in specimen after 1 week. There were no significant differences between the test group and control group in histological evaluations. Conclusion: In summary, the anodized surface showed slightly favorable results and it is postulated that it may facilitate improved stability in bone.