• Title/Summary/Keyword: Removal of dental implant

Search Result 156, Processing Time 0.028 seconds

VERTICAL DISTRACTION OF ALVEOLAR BONE FOR PLACEMENT OF DENTAL IMPLANT (치과 임플란트 식립을 위한 치조골의 수직적 신장술)

  • Oh, Jung-Hwan;Lazar, Frank;Zoeller, Joachim E.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.326-329
    • /
    • 2002
  • Adequate alveolar bone height and width are required for the successful placement of dental implants. Conventional therapeutic regimens for alveolar atrophy are bone grafts or augmentation using allografts and membrane (GBR). Conventional graft techniques have some limitations and complications such as infection, soft tissue problem and high resorption rate. Recently, distraction osteogenesis of alveolar bone is considered as a new alternative for ridge augmentation. Distraction osteogenesis was originally defined and popularized by Ilizarov for lengthening of long bone. Some clinicians have tried to apply distraction osteogenesis in treatment of maxillofacial discrepancies. It was also used to augment alveolar bone. Cologne study group successfully applied the technique for augmentation of alveolar bone and designed several miniplate-distractor systems fabricated by Martin Medizintechnik GmbH in Germany. Vertical distraction of alveolar bone was successfully completed in 104 patients with miniplate-distractor systems. The mean distance of distraction was 10.2mm (range: 6-15 mm) and the mean length of segment was 45 mm (range: 6-127 mm). 162 dental implants in 54 patients were placed immediately or 4 weeks later after removal of the distractor. The results of our study show that vertical distraction of alveolar bone is an effective and reliable technique to restore alveolar atrophy and alveolar vertical defect caused by trauma or tumor.

A case report about the reconstruction procedures of the previously failed cylinderical implants site using distraction osteogenesis

  • Lee, Jung-Tae;Park, Shin-Young;Yi, Yang-Jin;Kim, Young-Kyun;Lee, Hyo-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.2
    • /
    • pp.84-89
    • /
    • 2015
  • We report the eventually successful treatment of a huge bone defect and peri-implantitis following reconstruction of a previously failed intra-mobile cylinder implant system (IMZ) implant site using distraction osteogenesis (DO). In the anterior mandible, two IMZ implants failed and surgical debridement was performed in accordance to the patient's needs. Thereafter, mobility and suppuration were decreased and the patient visited the dental clinic on a regular basis for oral health maintenance. However, the inflammation did not resolve, and the bone destruction around the implants progressed for 4 years. Finally, the implants failed and a severe bone defect remained after implant removal. To reconstruct the bone defects, we attempted bone graft procedures. Titanium mesh was unsuccessfully used to obtain bone volume regeneration. However, DO subsequently was used to obtain sufficient bone volume for implant placement. The new implants were then installed, followed by prosthetic procedures. In conclusion, progression of peri-implantitis could not be arrested despite surgical intervention and repeated maintenance care for 3 years. Reconstruction of the peri-implantitis site was complicated due to its horizontal and vertical bone defects. Lesions caused by implant failure require an aggressive regenerative strategy, such as DO. DO was successful in reconstruction of a peri-implantitis site that was complicated due to horizontal and vertical bone defects.

Influence of the Dental Implant Abutment Screw Coating Materials on Joint Stability (임플란트 지대주나사 코팅이 결합안정성에 미치는 영향)

  • Lim, Hyun-Pil;Park, Young-Sun;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yoon, Suk-ja
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.157-169
    • /
    • 2009
  • The aim of this study was to evaluate effect of implant abutment screw coating treatment on joint stability, investigating mechanical properties of these. For this study used $ExFeel^{(R)}$ external hexed implant system and $15mm{\times}1mm$ discs. Experimental group was $1{\mu}m$ TiN, TiCN, TiC coated abutment screws and discs. To know mechanical property, i evaluated adhesion strength, surface hardness, using disc, corrosion test using screw. The results were as follows : rotation angle of coated screws increased than that of non-coated screw because of lower friction coefficient, especially TiC coated screw group had the largest value, but removal torque decreased in all coated screws (p<0.05). Torque loss before and after fatigue test was the smallest in TiC-coated screws, and the largest in non-coated screws (p<0.05), and there was no statistically significant difference between dry condition and wet condition of screws because of higher surface hardness and lower friction coefficient. From the above results, TiN, TiCN, TiC coating group had high abrasion resistance, especially TiC coated group which had low torque-consuming, high rotation angle as low friction coefficient will be considered to influence on implant abutment screw joint stability positively.

VERTICAL DISTRACTION OSTEOGENESIS FOR IMPLANT INSTALLATION ON THE RECONSTRUCTED MANDIBLE WITH FREE FIBULAR FLAP (하악골 재건시 사용된 유리비골피판에서 임플란트 식립을 위한 수직적 골신장술)

  • Paeng, Jun-Young;Lee, Jin-Yong;Myoung, Hoon;Hwang, Soon-Jung;Seo, Byoung-Moo;Choi, Jin-Young;Lee, Jong-Ho;Choung, Pill-Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.579-585
    • /
    • 2006
  • Introduction: The fibular free flap is now considered as the first choice for long mandibular discontinuity defect. In spite of its good bone quality for implant installation, its diameter is too narrow to rehabilitate the masticatory function with implant installation. In this report, distraction osteogenesis was used for the augmentation of bone to install the dental implant in the mandible which was reconstructed with a vascularized fibular free flap. Patients and Methods: Three patients undertook the vertical augmentation of grafted fibular bone and dental implants were installed. On the day 8 post-surgery, the activation of the distractor was started at the rate of 1 mm twice a day. The total amount of distraction was 15 mm in two patients and 12.5 mm in one patient. Twelve implants were installed in three patients. Dental implants were simultaneously installed during removal of the distraction device in two patients. In one patient, the implant installation was delayed after device had been removed. All three patients showed the symptoms of mild to severe postoperative infection during the activation and consolidation. However, the distracted site showed undisturbed bone regeneration. Conclusion: The distraction osteogenesis showed the reliable results for the vertical augmentation of fibular bone which was used for the mandibular reconstruction. However, the great tendency of postoperative infection must be considered and clinically controlled.

The effect of pretreating resorbable blast media titanium discs with an ultrasonic scaler or toothbrush on the bacterial removal efficiency of brushing

  • Koh, Minchul;Park, Jun-Beom;Jang, Yun-Ji;Ko, Youngkyung
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.6
    • /
    • pp.301-307
    • /
    • 2013
  • Purpose: This in vitro study was performed to assess the adherence of Porphyromonas gingivalis to a resorbable blast media (RBM) titanium surface pretreated with an ultrasonic scaler or toothbrush and to evaluate the effects of the treatment of the RBM titanium discs on the bacterial removal efficiency of brushing by crystal violet assay and scanning electron microscopy. Methods: RBM titanium discs were pretreated with one of several ultrasonic scaler tips or cleaned with a toothbrush. Then the titanium discs were incubated with P. gingivalis and the quantity of adherent bacteria was compared. The disc surfaces incubated with bacteria were brushed with a toothbrush with dentifrice. Bacteria remaining on the disc surfaces were quantified. Results: A change in morphology of the surface of the RBM titanium discs after different treatments was noted. There were no significant differences in the adherence of bacteria on the pretreated discs according to the treatment modality. Pretreatment with various instruments did not produce significant differences in the bacterial removal efficiency of brushing with dentifrice. Conclusions: Within the limits of this study, various types of mechanical instrumentation were shown to cause mechanical changes on the RBM titanium surface but did not show a significant influence on the adherence of bacteria and removal efficiency of brushing.

Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment (임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교)

  • Choi, Jae-Won;Chae, Sung-Ki;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.173-180
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles. Materials and methods: The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM). Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles. Results: In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P<.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P<.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix. Conclusion: Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.

Labial and lingual/palatal bone thickness of maxillary and mandibular anteriors in human cadavers in Koreans

  • Han, Ji-Young;Jung, Gyu-Un
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.2
    • /
    • pp.60-66
    • /
    • 2011
  • Purpose: The aim of this study is to evaluate the buccal and lingual bone thickness in the anterior teeth and the relationship between bone thickness and the tissue biotype. Methods: Three male and two female human cadaver heads (mean age, 55.4 years) were used in this study. First, the biotype of periodontium was evaluated and categorized into a thick or a thin group. Next, full thickness reflections of the mandible and the maxilla to expose the underlying bone for accurate measurements in the anterior regions were performed. After the removal of the half of the alveolar bone, the probe with a stopper was used to measure the thickness of bone plate at the alveolar crest (AC), 3 mm apical to the alveolar crest (AC-3), 6 mm apical to the alveolar crest (AC-6), and 9 mm apical to the alveolar crest (AC-9). The thickness of the buccal plates at the alveolar crest were $0.97{\pm}0.18\;mm$,$0.78{\pm}0.21\;mm$, and $0.95{\pm}0.35\;mm$ in the maxillary central incisors, lateral incisors, and canines, respectively. The thickness of the labial plates at the alveolar crest were $0.86{\pm}0.59\;mm$, $0.88{\pm}0.70\;mm$, and $1.17{\pm}0.70\;mm$ in the mandibular central incisors, lateral incisors and canines, respectively. Conclusions: The thickness of the labial plate in the maxillary anteriors is very thin that great caution is needed for placing an implant. The present study showed the bone thickness of maxillary and mandibular anteriors at different positions. Therefore, these data can be useful for the understanding of the bone thickness of the anteriors and a successful implant placement.

Efficacy of sonic-powered toothbrushes for plaque removal in patients with peri-implant mucositis

  • Lee, Jungwon;Lim, Jong Heun;Lee, Jungeun;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Ku, Young;Lee, Yong-Moo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.2
    • /
    • pp.56-61
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the effectiveness of powered toothbrushes for plaque control in patients with peri-implant mucositis, in comparison with manual toothbrushes. Methods: This randomized, prospective, controlled, clinical parallel study compared the efficacy of manual and powered toothbrushes for plaque control in implant restorations. Patients with bleeding on probing, no residual pocket depth (as indicated by a pocket probing depth ${\geq}5mm$), and no radiological peri-implant bone loss were eligible for this study. Patients were requested to complete a questionnaire describing their oral hygiene habits. The duration and frequency of tooth brushing were recorded by subjects in order to assess their compliance. Clinical parameters, including the modified plaque index (mPI), the modified sulcus bleeding index (mSBI), and clinical photographs (buccal and lingual views) were recorded at baseline and at one-month and two-month follow-up visits. Results: Statistically significant differences between patients who used manual toothbrushes and those who used powered toothbrushes were found regarding the frequency of tooth brushing per day and the duration of brushing at one-month and two-month follow-up visits, while no statistically significant differences were found relating to other oral hygiene habits. A statistically significant difference in patient compliance for tooth brushing was found at one month, while no difference was found at two months. Statistically significant decreases in the mPI and the mSBI were observed in both groups from baseline to the one- and two-month follow-ups. The overall reduction of these parameters was not significantly different between the two groups, except for mPI reduction between baseline and one month of follow-up. Conclusions: Sonic-powered toothbrushes may be a useful device for plaque control in patients with peri-implant mucositis.

Wound Healing After Gingivectomy Using Pulsed Nd : YAG Laser In The Rat (백서에서 Pulsed Nd : YAG Laser에 의한 치은절제술후의 치유양상)

  • Kim, Ok-Su;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.293-308
    • /
    • 1996
  • Recently, dental laser have been applied for removal of soft tissues, hemostasis and blood coagulation, removal of benign and malignant tumor, treatment of leukoplakia, aphthous ulcer and herpetic lesion, implant second surgery, removal of granulation tissue, frenectomy, clinical crown lengthening, gingivectomy, gingivoplasty, and treatment of dentin hypersensitivity. Even though the frequency of laser treatment is increasing, the research on the healing process after gingivectomy using pulsed Nd : YAG laser is very rare. The purpose of this study was to observe and compare the wound healing after gingivectomy using scalpel and pulsed Nd : YAG laser in the rat. Gingivectomy was performed using pulsed Nd : YAG laser(SUNRISE Technologies, U.S.A., 1.5 Watts, 10 pps) on the buccal gingiva of right maxillary first molar and using scalpel(No.12) on the contralateral side. Those sites treated by surgical scalpel were designated as the control, and by pulsed Nd : YAG laser as the experimental group. Animals were sacrificed at 1, 2, 3, 5, 7, 11 and 14 days postoperatively, and specimens were histologically observed under light microscope. The results were as follows : 1. Clinical observation Normal color and shape were observed at the 5th day ill the control group and the 7th day in the experimental group. 2. Histologic findings 1) In the control group, denser inflammatory infiltration was observed. 2) Epithelialization started at the 2nd day in the control group, similar to the experimental group, and completed at the 11th to the 14th day postoperatively. 3) In the experimental group, connective tissue showed the vacuole formation and degenerative change during early healing period. Healing of connective tissue was slower in the experimental group than in the control group by 2 days. 4) In the both groups, wound healing was completed at the 2nd week. From this study, gingivectomy using pulsed Nd : YAG laser seems to result in a little delayed wound healing process, compared to the gingivectomy using scalpel. Considering the clinical advantages of laser surgery, pulsed Nd : YAG laser might be useful device for gingivectomy.

  • PDF

Influence of immediate loading on the removal torque value of mini-screws (교정력의 즉시 부하가 미니스크류의 제거 회전력에 미치는 영향의 평가)

  • Sun, Seung-Bum;Kang, Yoon-Goo;Kim, Seung-Hun;Mo, Sung-Seo;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.400-406
    • /
    • 2007
  • The purpose of this experimental study was to evaluate the effect of immediate orthodontic loading on the stability at the bone-implant interface of titanium miniscrews in a rabbit model. Methods: Forty titanium miniscrews (1.6 mm diameter, 8 mm length) were inserted in the tibiae of 10 rabbits. Twenty test group miniscrews were subjected to continuous orthodontic forces of 200g immediately after implantation for a period of 6 weeks. The remaining 20 control group miniscrews were left unloaded for the same follow-up interval. Removal torque values were recorded using a digital torque gauge. An independent t-test was performed. Results: All the miniscrews were stable, and exhibited no mobility or displacement throughout the experimental period. Histologically, miniscrews were well-integrated into bone. No statistically significant differences in removal torque data were found between the loaded test and the unloaded control groups. Conclusions: These findings suggest that titanium miniscrews can be used as anchoring units for orthodontic tooth movement immediately after insertion.