• Title/Summary/Keyword: Remote testing

Search Result 184, Processing Time 0.025 seconds

A Study on the Implementation of the Management System for Mini-MAP Network (Mini-MAP 네트워크를 위한 관리 시스템 구현에 관한 연구)

  • Jung Gyu Kim
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.12
    • /
    • pp.1-9
    • /
    • 1993
  • In this paper, to realize the network management function in automated manufacturing network Mini-MAP, the network management requirements are analyzed and the network management system is implemented on the basis of this analysis. The implemented management system which has both local management and remote management mechanism is considered as a single domain on the Mini-MAP network. Here, the remote management functions consist of network status, monitoring and remote operations and the local management functions have parameter display and network self testing. The MAP network controller is designed according to the MAP version 3.0 specifications and IEEE 802 standards. the operations of network management system are certified througth the test environments which consists of the implemented network adaptor and softwares for Mini-MAP.

  • PDF

Assessing Sea Surface Temperature in the Yellow Sea Using Satellite Remote Sensing Data

  • Lee, Kyoo-seock;Kang, Hee-Sook
    • Korean Journal of Remote Sensing
    • /
    • v.6 no.1
    • /
    • pp.39-47
    • /
    • 1990
  • The first Marine Observation Satellite(MOS) was launched by National Space Development Agency of Japan on February 19, 1987, and it is equipped with three sensons covering visible, infrared, and microwave region. One of them is Visible and Thermal Infrared Radiometer(VTIR) whose main objective is to detect the Sea Surface Temperature(SST). The objective of this study was to process the MOS data using Cray-2 supercomputer, and to assess the SST in the Yellow Sea. In order to implement this objective, the linear regression model between the ground truth data and the corresponding digital number of VTIR in MOS was used to establish the relationship. After testing the significance of the regression model, the SST map of the whole Yellow Sea was derived based on the model. The digital SST map representing the study area showed certain pattern about the SST of Yellow Sea in March and April. In conclusion, the VTIR data in MOS is also useful in investigating SST which provides the information about the Yellow Sea water current in the spring.

A Hybrid Cloud Testing System Based on Virtual Machines and Networks

  • Chen, Jing;Yan, Honghua;Wang, Chunxiao;Liu, Xuyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.4
    • /
    • pp.1520-1542
    • /
    • 2020
  • Traditional software testing typically uses many physical resources to manually build various test environments, resulting in high resource costs and long test time due to limited resources, especially for small enterprises. Cloud computing can provide sufficient low-cost virtual resources to alleviate these problems through the virtualization of physical resources. However, the provision of various test environments and services for implementing software testing rapidly and conveniently based on cloud computing is challenging. This paper proposes a multilayer cloud testing model based on cloud computing and implements a hybrid cloud testing system based on virtual machines (VMs) and networks. This system realizes the automatic and rapid creation of test environments and the remote use of test tools and test services. We conduct experiments on this system and evaluate its applicability in terms of the VM provision time, VM performance and virtual network performance. The experimental results demonstrate that the performance of the VMs and virtual networks is satisfactory and that this system can improve the test efficiency and reduce test costs through rapid virtual resource provision and convenient test services.

CHANGES OF SOFTWARE UNIT TESTING TOOL - ATTOL TO TESTRT

  • Paek, Su-Hyun;Kang, Soo-Yeon;Yang, Koon-Ho;Choi, Seong-Bong
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.84-87
    • /
    • 2008
  • ATTOL is a software unit testing tool produced by the ATTOL Testware SA in France. It automates the entire software unit testing process: test plan template and test program generation, test program execution, test result analysis and test report generation. ATTOL is suited for the development of embedded software as it allows programmers to operate in native and cross development environments. Particularly, it is used for the development of the flight software which is embedded in the Communication Ocean Meteorological Satellite (COMS). As the flight software is mission-critical, it requires the strict software quality and high testing constraints. The flight software of COMS is verified by ATTOL in native and cross platforms. In 2002, ATTOL was taken over by the IDM Rational Software and has been supplied with the name of Test RealTime (TestRT). The test process of TestRT becomes different from that of ATTOL as TestRT provides the new functionalities that were absent from ATTOL. TestRT provides the new features in the test script language, as well. In this paper, we compare the test process of ATTOL to TestRT With an example of COMS and explain what has been changed in the test script language.

  • PDF

Recent developments in remote inspections of ship structures

  • Poggi, Laura;Gaggero, Tomaso;Gaiotti, Marco;Ravina, Enrico;Rizzo, Cesare Mario
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.881-891
    • /
    • 2020
  • In recent years robotics has become an important resource in engineering. Adoption of Robotics and Autonomous Systems (RAS) in activities related to ship inspections has obvious potential advantages, but also arises particular challenges, both from technical and legal viewpoints. The ROBINS project (ROBotics technology for INspection of Ships) is a collaborative project co-funded within the H2020 EU Research and Innovation programme call, aimed at filling the gap between current ship inspections approach and available robotic technology, both from technological and regulatory point of view. Main goal of the present work is to highlight how ship inspections are currently carried out by humans, how they could be improved using RAS, even if not completely autonomous for the time being, at least in selected operational scenarios and how the performances of RAS platforms can be tested to assess their effectiveness in carrying out surveys onboard. In such a framework, a testing facility aimed at assessing RAS' capabilities as well as providing suitable environment for their development has been built and it is still under development along with dedicated testing protocols, able to assess the equivalence between human and RAS inspection of ship and marine structures. The features of a testing facility where RAS can be tested and the testing protocols are presented, showing how technological and regulatory gaps are filled.

Design of Remote Field Eddy Current Sensor for Water-Wall Tube Inspection using Simulation (시뮬레이션을 활용한 유동층보일러 수냉벽튜브 검사용 원격장 와전류 탐상 센서 설계)

  • Gil, Doo Song;Kwon, Chan Wool;Cho, Yong-Sang;Kim, Hak-Joon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.33-38
    • /
    • 2019
  • Thermal power generation accounts for the highest percentage of domestic power generation, among which coal-fired boiler generation accounts for the highest percentage. Coal boilers generate harmful substances and fine dust during coal combustion and have a serious effect on air pollution. So, fluidized-bed boilers have been introduced as eco-friendly coal boilers. It uses a fluid medium which affect the combustion temperature of coal. Because of it fluidized-bed boilers emit less pollutants than original one. Water-wall tubes play an important role in this fluidized bed boiler. Due to the fluid medium, the wall damage is more severe than the existing boiler. However, there is no quantitative maintenance technique in Korea yet. Remote field eddy current testing is a non-destructive evaluation technique that is often used for inspection of inner and outer wall of tube. it can inspect with non-contact and high speed. However, it is an inspection that proceeds from inside the pipe, and the water-wall tube is not able to enter the interior. In this study, we designed and simulated an external remote field eddy current sensor suitable for water-wall tube of a fluidized - bed boiler using simulations. By obtaining a signal similar to the existing remote field eddy current test, the criteria for the external remote field eddy current sensor design can be presented.

A Study on the Performance Evaluation of Cycloid Reducer (사이클로이드 감속기의 성능평가에 관한 연구)

  • Park, Jin-Seok;Kim, Ki-Hun;Kim, Lae-Sung;Qin, Zhen;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.113-118
    • /
    • 2017
  • In this paper, a study on the performance evaluation of a cycloid reducer for remote weapons systems is presented. Reduction gears applied to remote weapons vehicles need to be compact and capable of large torque transmissions as well as require structural optimization, high load capacity, and high precision position control. To meet these requirements, a cycloid reducer with low backlash, high precision, high overload capability, high rigidity, and high efficiency is required. Thus, a cycloid reducer with a reduction ratio of 127:1, backlash of 1 arcmin (1/60 deg) or less, and reduction gear efficiency of 70% or more, which are the design requirements for a remote weapons system, was designed utilizing a design and analysis program (HEXAGON) for gear engineering. To confirm the performance of the cycloid reducer, the hardness of the main components of the manufactured cycloid reducer, reduction ratio, and efficiency were measured.

Design and Implementation of Optimal Control Algorithms for Building Energy Management (빌딩 에너지 관리 최적화 알고리즘 설계 및 구현)

  • Jin Jung-Hwa;Chung Sun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

Quantitative Evaluation of Remote Field Eddy Current Defect Signals (배관 결함부 원거리장 와전류 신호 정량화 연구)

  • Jeong, Jin-Oh;Yi, Jae-Kyung;Kim, Hyoung-Jean
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.555-561
    • /
    • 2000
  • The remote field eddy current (RFEC) inspection was performed on the ductile cast iron pipes with nominal outer diameter of 100mm, which were machined with various shapes and sizes of defects. Ductile cast iron pipes which are used as water supply pipe have the non-uniform thickness and asymmetric cross section due to relatively high degree of allowable errors during the manufacturing processes. These characteristics of ductile cast in pipes cause the long range background noises in RFEC signals along the pipe. In this study, tile machined defects in pipes were effectively classified by the moving window average (MWA) method which eliminated the long-range noise. The voltage plane polar plots (VPPP) method was used to quantitatively evaluate the depth and circumferential degree of defects. The VPPP signatures showed that the angle between defect signature and the normalized in-phase component on the VPPP is linear to the depth of defects. The nondestructive RFEC technique proved to be capable of quantitatively evaluating the machined defects of underground water supply pipe.

  • PDF

Development of PKNU3: A small-format, multi-spectral, aerial photographic system

  • Lee Eun-Khung;Choi Chul-Uong;Suh Yong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.5
    • /
    • pp.337-351
    • /
    • 2004
  • Our laboratory originally developed the compact, multi-spectral, automatic aerial photographic system PKNU3 to allow greater flexibility in geological and environmental data collection. We are currently developing the PKNU3 system, which consists of a color-infrared spectral camera capable of simultaneous photography in the visible and near-infrared bands; a thermal infrared camera; two computers, each with an 80-gigabyte memory capacity for storing images; an MPEG board that can compress and transfer data to the computers in real-time; and the capability of using a helicopter platform. Before actual aerial photographic testing of the PKNU3, we experimented with each sensor. We analyzed the lens distortion, the sensitivity of the CCD in each band, and the thermal response of the thermal infrared sensor before the aerial photographing. As of September 2004, the PKNU3 development schedule has reached the second phase of testing. As the result of two aerial photographic tests, R, G, B and IR images were taken simultaneously; and images with an overlap rate of 70% using the automatic 1-s interval data recording time could be obtained by PKNU3. Further study is warranted to enhance the system with the addition of gyroscopic and IMU units. We evaluated the PKNU 3 system as a method of environmental remote sensing by comparing each chlorophyll image derived from PKNU 3 photographs. This appraisement was backed up with existing study that resulted in a modest improvement in the linear fit between the measures of chlorophyll and the RVI, NDVI and SAVI images stem from photographs taken by Duncantech MS 3100 which has same spectral configuration with MS 4000 used in PKNU3 system.