• Title/Summary/Keyword: Remote Data Transmission

Search Result 327, Processing Time 0.038 seconds

Smart Sensor Management System Supporting Service Plug-In in MQTT-Based IIoT Applications

  • Lee, Young-Ran;Kim, Sung-Ki
    • Journal of Multimedia Information System
    • /
    • v.9 no.3
    • /
    • pp.209-218
    • /
    • 2022
  • Industrial IoT applications, including smart factories, require two problem-solving to build data monitoring systems required by services from distributed IoT sensors (smart sensors). One is to overcome proprietary protocols, data formats, and hardware differences and to uniquely identify and connect IoT sensors, and the other is to overcome the problem of changing the server-side data storage structure and sensor data transmission format according to the addition or change of service or IoT sensors. The IEEE 1451.4 standard-based or IPMI specification-based smart sensor technology supports the development of plug-and-play sensors that solve the first problem. However, there is a lack of research that requires a second problem-solving, which requires support for the plug-in of IoT sensors into remote services. To propose a solution for the integration of these two problem-solving, we present a IoT sensor platform, a service system architecture, and a service plugin protocol for the MQTT-based IIoT application environment.

Smartphone Real Time Streaming Service using Parallel TCP Transmission (병렬 TCP 통신을 이용한 스마트폰 실시간 스트리밍 서비스)

  • Kim, Jang-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.5
    • /
    • pp.937-941
    • /
    • 2016
  • This paper proposed an efficient multiple TCP mechanism using Android smartphones for remote control video Wi-Fi stream transmission via network communications in real time. The wireless video stream transmission mechanism can be applied in various area such as real time server stream transmissions, movable drones, disaster robotics and real time security monitoring systems. Moreover, we urgently need to transmit data in timely fashion such as medical emergency, security surveillance and disaster prevention. Our parallel TCP transmission system can play an important role in several area such as real time server stream transmissions, movable drones, disaster robotics and real time security monitoring systems as mentioned in the previous sentence. Therefore, we designed and implemented a parallel TCP transmission (parallel stream) for an efficient real time video streaming services. In conclusion, we evaluated proposed mechanism using parallel TCP transmission under various environments with performance analysis.

A Practical Voltage Error Correction Technique for Distribution System under Distribution Automation Environment

  • Aslam, Muhammad;Kim, Hyung-Seung;Choi, Myeon-Song;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.669-676
    • /
    • 2018
  • Transmission system has been well studied since long time and power system techniques of distribution system are more or less derived from transmission system. However, unlike transmission systems, many practical issues are encountered in the distribution system. Considerable amount of error is observed in voltage obtained from the Feeder Remote Terminal Units (FRTUs) measured by the pole mounted PTs along the distribution feeder. Load uncertainty is also an issue in distribution system. Further, penetration of Distributed Generators (DGs) creates voltage variations in the system. Hybrid radial/ loop distribution system also make it complicated to handle distribution system. How these constraints to be handled under Distribution Automation (DAS) environment in order to obtain error free voltage is described in this paper and therefore, a new approach of voltage error correction technique has been proposed. The proposed technique utilizes reliable data from substation and the FRTUs installed in DAS. The proposed technique adopts an iterative process for voltage error correction. It has been tested and proved accurate not only for conventional radial systems but also for loop distribution systems.

m-Health System for Processing of Clinical Biosignals based Android Platform (안드로이드 플랫폼 기반의 임상 바이오신호 처리를 위한 모바일 헬스 시스템)

  • Seo, Jung-Hee;Park, Hung-Bog
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.7
    • /
    • pp.97-106
    • /
    • 2012
  • Management of biosignal data in mobile devices causes many problems in real-time transmission of large volume of multimedia data or storage devices. Therefore, this research paper intends to suggest an m-Health system, a clinical data processing system using mobile in order to provide quick medical service. This system deployed health system on IP network, compounded outputs from many bio sensing in remote sites and performed integrated data processing electronically on various bio sensors. The m-health system measures and monitors various biosignals and sends them to data servers of remote hospitals. It is an Android-based mobile application which patients and their family and medical staff can use anywhere anytime. Medical staff access patient data from hospital data servers and provide feedback on medical diagnosis and prescription to patients or users. Video stream for patient monitoring uses a scalable transcoding technique to decides data size appropriate for network traffic and sends video stream, remarkably reducing loads of mobile systems and networks.

Development of a Web Service System of Large Capacity Image Data: Focusing on the System Established for Ministry of Environment (대용량 영상자료 웹 서비스 시스템의 개발: 환경부 구축 사례 중심으로)

  • Lee, Sang-Ik;Shin, Sang-Hee;Choi, Yun-Soo;Lee, Im-Pyeong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.3 s.30
    • /
    • pp.61-67
    • /
    • 2004
  • Satellite and aerial images are effectively used to monitor ecological and environmental situation. More and more officials in the Ministry of Environment thus need to utilize these image data for various administrative affairs. However, it is difficult not only to deliver to the officials these image data mostly of large capacity through network but also for them to actively use the delivered data without specialized knowledge in remote sensing and image processing. Therefore, we established a large rapacity image data service system employing image compressive transmission and web-based image processing techniques. This system allows the officials to rapidly access all the associated image data and conveniently utilize the data using various functions implemented for remote sensing, image processing, GIS operations. Consequently, this system have been actively utilized for the decision making processes of the officials and hence accomplished a great reduction in the resources required for the data analysis for various administrative affairs.

  • PDF

Fault Current Discrimination of Power Line using FCM allowing self-organization (FCM에 기반한 자가생성 지도학습알고리즘을 이용한 전력선의 고장전류 판별)

  • Jeong, Jong-Won;Won, Tae-Hyun;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.368-369
    • /
    • 2011
  • This article suggests an online-based remote fault current mode discrimination method in order to identify the causes of the power line faults with various causes. For that, it refers to existing cause identification methods and categorizes modes by fault causes based on statistical techniques beforehand and performs the pretreatment process of fault currents by each cause acquired from the fault recorder into a topological plane in order to extract the characteristics of fault currents by each cause. After that, for the fault mode categorization, it discriminates modes by each cause using data by each cause as leaning data through utilizing RBF network based on FCM allowing self-organization in deciding the middle layer. And then it tests the validity of the suggested method as applying it to the data of the actual fault currents acquired from the fault recorder in the electric power transmission center.

  • PDF

Fault Current Discrimination of Power Line using Phase Space (위상평면을 이용한 전력선의 고장전류 판별)

  • Jeong, Jong-Won;Lee, Joon-Tark
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.86-88
    • /
    • 2009
  • This article suggests an online-based remote fault current mode discrimination method in order to identify the causes of the power line faults with various causes. For that, it refers to existing cause identification methods and categorizes modes by fault causes based on statistical techniques beforehand and performs the pre-treatment process of fault currents by each cause acquired from the fault recorder into a phase space in order to extract the characteristics of fault currents by each cause. After that, for the fault mode categorization, it discriminates modes by each cause using data by each cause as leaning data through utilizing RBF network. And then it tests the validity of the suggested method as applying it to the data of the actual fault currents acquired from the fault recorder in the electric power transmission center.

  • PDF

Position Control of Linear Actuator with Uncertain Time Delay in VDN

  • Kim, Jonghwi;Kiwon Song;Park, Gi-Sang;Park, Gi-Heung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.118.2-118
    • /
    • 2002
  • Uncertain time delay happens when the process reads the sensor data and sends the control input to the plant located at a remote site in distributed control system. As in the case of data network using TCP/IP, VDN that integrates both device network and data network has uncertain tim e delay. Uncertain time delay can cause degradation in stability of distributed control system based on VDN. This paper investigates the transmission characteristic of VDN and suggests a control scheme based on the Smith's predictor to minimize the effect of uncertain time delay. The validity of the proposed control scheme is demonstrated with tracking position control of experiments.

  • PDF

Diagnostic/prognostic health monitoring system and evaluation of a composite bridge

  • Mosallam, A.;Miraj, R.;Abdi, F.
    • Smart Structures and Systems
    • /
    • v.5 no.4
    • /
    • pp.397-413
    • /
    • 2009
  • Composite bridges offer many advantages compared to current steel and aluminum bridges. This paper presents the results of a comprehensive on-going research program to develop innovative Diagnostic Prognostic System (DPS) and a structural evaluation of Composite Army Bridge (CAB) system. The DPS is founded on three technologies: optical fiber sensing, remote data transmission, and virtual testing. In developing this system, both laboratory and virtual test were used in different damage scenarios. Health monitoring with DPS entailed comparing live strain data to archived strained data in various bridge locations. For field repairs, a family of composite chords was subjected to simple ramp loads in search of ultimate strength. As such, composite bridge specimens showcased their strengths, heralded the viability of virtual testing, highlighted the efficacy of field repair, and confirmed the merits of health monitoring.

THE RELATION BETWEEN HPA AND COMS MULTI-CARRIER

  • Park Durk-Jong;Yang Hyung-Mo;Hyun Dae-Wan;Ahn Sang-Il;Kim Eun-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.564-566
    • /
    • 2005
  • The relation between HPA (High Power Amplifier) and COMS (Communication Ocean Meteorological Satellite) multi-carrier is analyzed in this paper. MODAC (Meteorological and Ocean Data Application Center) has a primary mission to transmit processed data, HRIT (High Rate Information Transmission) and LRIT (Low Rate Information Transmission), which is normalized and calibrated by pre-processing. It is also replaced with the SOC (Satellite Operation Center) in emergency case and can transmit the command and ranging tones for operation of COMS. From the result of simulation with modelled HPA, it is found that the multi-carrier in one HPA can give rise to an inter-modulation which makes harmonic and spurious elements increase in-band. Under the environment of these increased parasitic elements, the degradation of multi-carrier's quality is estimated from the ratio of the amount of noise to total output power of HPA.

  • PDF