• Title/Summary/Keyword: Remodeling Building

Search Result 397, Processing Time 0.031 seconds

A Study on the Radiation Shielding Analysis for Reinforcing the Hot Cell Regular Concrete Shield Wall (핫셀의 일반 콘크리트 보강을 위한 방사선 차폐해석 연구)

  • 조일제;황용화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.985-990
    • /
    • 2003
  • In order to demonstrate Advanced Spent Fuel Conditioning Process (ACP), shielding facilities such as hot cell suitable to handling radionuclides and process property will be necessary. But the construction of new facilities needs much money, man-power and time, it is now scheduled to remodel the hot cell, which has already been installed and maintained at Irradiated Material Experiment Facility (IMEF) in the Korea Atomic Energy Research Institute (KAERI). The basic structure and concrete shield wall of hot cell partly have been constructed on the base floor in IMEF building in current status. And hot cell after remodeling will be used for carrying out the lab-scale experiment of ACP. The hot cell was built in accordance with 35 curies of fe-59(1.2 MeV) as design criteria of radiation dose limit. But the radioactive source of ACP is expected to be much higher than design criteria of IMEF, shielding ability of the hot cell in the current status is unsatisfactory to the hot test of ACP. Therefore shield wall shall be reinforced with heavy concrete, steel or lead. In this paper, dose rates are calculated according to ACP source, shielding materials, etc., and reinforcement structures are determined considering the current situation of hot cells, installation of shield windows and the easiness of work.

  • PDF

POE of Toilet of Elementary School in Rural Area (농촌지역 초등학교 화장실의 거주후 평가 연구 -H군의 D초등학교를 중심으로)

  • Han, Jong Koo;Park, Tong So
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.9 no.1
    • /
    • pp.9-16
    • /
    • 2007
  • Educational Facility has a specialty that similar design is repeatedly taken place so the importance of POE(Post Occupancy Evaluation) is increased for the improvement of problem appeared at the former projects. The POE could provides help to the design of next project and the direction when the need of remodeling is faced. Through the process of POE, the repeat of design mistakes could be prevented and the good information related with building efficiency and other problems could be applied to the design of next school project . In this study, the POE of Manbalro(barefoot) toilet of D Elementary school in rural area of H county is performed. The toilet is renovated as an educational environment improvement project of H county educational office in Chungcheong Namdo Province. The study is focused on the user's behavior at Manbalro toilet for carrying out indicative POE by the subjective response of user's. From the research, several being reformed items is proposed however the toilet is evaluated as a successful project that design purpose of initial stage is applied well.

  • PDF

Structural Performance Evaluation of VES Damper System subjected to Cyclic Loadings(CST30) (가력하중을 통한 CST30제진댐퍼시스템의 구조성능 평가)

  • Kim, DaeHun;Lee, DongKyu;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.2
    • /
    • pp.61-68
    • /
    • 2015
  • The performance enhancement of various structural building systems from natural hazards has become an inctreasingly important issue in engineering field. In this paper, visco-elastic(VE) CST30 damping systems were tested under cyclic loadings to evaluate their performance in terms of ductility and energy dissipation. Main test variables are relative shear stiffness, rate of loading frequency, and thickness of specimens to evaluate the seismic capacity based on the performance criteria. This experiment was performed using a total of 12 specimens, subjected to cyclic loadings up to a shear deformation of 500%. All the CST30 dampers provided a ductile and stable hysterestic behavior when subjected to the demands of large shear stiffness and different loading frequencies. The test results showed that the CST30 dampers are an effective damping systems to enhance the buildings performance for remodeling and retrofit of buildings.

Determining Appropriate Capacity on Installing Photovoltaic System at Deteriorated Educational Facilities

  • Lhee, Sang Choon;Choi, Young Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.23-29
    • /
    • 2014
  • With high acknowledgements of environmental conservation and energy saving, many architectural technologies using renewable energy have been recently applied at buildings which take about 20% of total energy consumption. Among renewable energy sources, the photovoltaic is considered as the most highly potential one due to advantages of infiniteness and cleanliness. Also, projects to install renewable energy systems have been continuously performed at deteriorated educational facilities as energy efficient remodeling projects or green school projects by the Korean government. This paper proposes appropriate capacities by school level on installing photovoltaic systems at deteriorated school buildings, based on the balance of annual electricity power demand and supply between buildings and systems. Using the Visual DOE program and Merit program, the appropriate installment capacity of photovoltaic system turned out be 40kWp at elementary school building and 60kWp at middle and high ones. In addition, annual energy use proved to be reduced by 20.2% at elementary school, 26.9% at middle school, and 21.0% at high school by installing photovoltaic systems with the appropriate capacities.

A Study of the Sectionalizing for Pipe Deterioration Evaluation in Industrial Facilities (산업시설 배관 노후도 평가를 위한 배관 섹션화 방안 연구)

  • Min, Hyuk-Ki;Kim, Sang-Bum;Kim, Byung-Woo;Kim, Hyoung-Ki;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.103-111
    • /
    • 2015
  • In general, no particularly well-established standards have been in place so far, for the method of evaluating the deteriorated level of pipes and ducts of industrial facilities. For that reason, the evaluation depends upon various studies which are based on the analysis of the residual life, thickness thinning, closure rate, and scale thickness that measure a few specific positions of pipes. It also depends upon the expertise in business operation and the specific techniques conducted by the inspection companies and institutions. This research introduces the concept of measuring units per section and the selection method of measurement points per section. Furthermore, specific methodologies were developed to plan and analyze deterioration level of industrial pipes and ducts by engineers and managers using a section map. Consequently, applying the outcomes from this study to the plant equipment of the incineration facility resulted in saving 42% of the repairing and remodeling cost.

A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments (공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구)

  • Yoon, Jong-Ho;An, Young-Sub;Kim, Byoung-Soo;Hwang, Sang-Kun
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

An Ecological Approach to Housing Experience of Korean Women in Malaysia (생태학적 접근으로 본 말레이시아 거주 한인 여성의 주거경험)

  • Hong, Hyung Ock
    • Human Ecology Research
    • /
    • v.53 no.4
    • /
    • pp.375-390
    • /
    • 2015
  • This study was designed to understand the residential experience of Korean women living in tropical country. For qualitative research, interviewees were selected by snowball sampling among Korean women living in Malaysia for over 20 years. The selection criteria for interviewees included husband's nationality, occupational experience, future living plan, frequency of travel to Korea. In-depth group and individual interviews were conducted from August 23 to October 7 2014. Subsequently (1) interviewees' general residential experiences in Malaysia were summarized, (2) interviewee's identity and lifestyle with housing pathways approach were clarified, (3) interviewees' residential experiences in 5 issues, reciprocity in residential area, intention of environmental change, meaning of housing and interaction, housing adaptation, and residential satisfaction/dissatisfaction were prescribed and interpreted. In conclusion, the reflection of interviewees' experiences in tropical country, suggested variations of housing structure type within a residential complex, air well and pocket by setback in building block for improving ventilation and noise prevention from neighbors, and ceiling fans in the house were suggested for the upcoming subtropical climate in Korea. Full option and minus options were also suggested for the presale market to reduce before occupancy remodeling needs. The research results implies valuable suggestions for a multicultural society, ecological housing and stronger communities.

A Study on the Space Design of Public library Based on User Behavior (도서관 이용자 행태에 따른 공공도서관 공간 구성에 관한 연구)

  • Kim, Tea-Seung;Kim, Eun-Ja
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.42 no.4
    • /
    • pp.311-328
    • /
    • 2008
  • New library building construction and the remodeling of old one is growing tendency is nation-wide recently. But there is no reflection of library user's view in the field of library construction. For the completion of the research the data was collected by bar-code scanner with user ID cards. Collected data was analysed by using crosstabulation and t-test. Around 2:00PM is peak time for library visit and the reading room for children is most frequent use space in library.

User Evaluation of University Learning Spaces (대학의 학습공간에 대한 사용자 인식 조사)

  • Koo, Sang Hoe;Lee, Hyun-Hee
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.3
    • /
    • pp.33-41
    • /
    • 2019
  • As the information age matures, the learning style of youth is changing rapidly. Students study at a variety of places such as cafe or lobbies utilizing various digital learning devices. Along with the place changes, learning methods are also changing. Student-centered learning methods such as smart learning, collaborative learning, and activity-based learning are increasingly being utilized instead of the traditional instructor-centered learning in which knowledge is unilaterally delivered. Accordingly, many universities are remodeling central libraries, and they are also transforming lobby spaces of the college buildings into simple but useful learning spaces. In this study, we analyze the characteristics of learning spaces in universities from the standpoint of the students. According to the analysis, overall satisfaction is high in terms of comfortable physical learning environments such as Wi-Fi, furniture, lighting, etc. But the spaces are still optimized for individual and intensive learning. There seems to be a lack of effort to support collaborative learning or activity-based learning. This observation is confirmed by the characteristics of the central library, and it is considered that the reason why the college buildings are preferred by students is that college buildings are more suitable for collaborative or activity-based learning than libraries.

Development of Form to Improve the Productivity of PC Structure Connections -Focused on Apartment Buildings- (PC구조 접합부공사의 생산성 향상을 위한 거푸집 개발 -공동주택을 중심으로-)

  • Kim, Seon-Hyung;Lee, Won-Suk;Kim, Sun-Kuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.5
    • /
    • pp.11-20
    • /
    • 2010
  • With the amendment to the Building Act in November of 2005 that offered incentives in terms of floor area ratio and number of stories to apartment buildings adopting the Rahmen structure to facilitate remodeling, the construction industry is paying more attention to PC structures. As connections between PC columns and beams require complex design, it is very difficult to install and remove forms. Since forms made of plywood for such connections are fabricated and installed on site, a significant amount of labor is required, and constructability is low. Furthermore, after concrete casting, the forms are removed in a state in which they cannot be recycled, which leads to a significant amount of construction waste. For this reason, a solution to address such issues needs to be studied. However, many researchers have focused only on the structural performance of PC structures in Korea and elsewhere, ignoring the need for research on the forms used in building PC structure connections. Therefore, this research aims to develop a form that can improve the productivity of PC structure connection construction, and compare it with conventional forms to highlight its contribution to gains in productivity and economic viability.