• Title/Summary/Keyword: Reline resin

Search Result 26, Processing Time 0.027 seconds

THE EFFECT OF DENTURE CLEANSERS ON THE BOND STRENGTH AND THE SURFACE HARDNESS OF RELINE RESIN TO DENTURE BASE RESIN (의치 세정제가 의치상 레진과 이장용 레진의 결합강도와 표면경도에 미치는 영향)

  • Kim Kyea-Soon;Jeong Hoe-Yeol;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.493-502
    • /
    • 2003
  • Statement of problem : Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour and resorption of underlyng bony structure. Self-curing hard reline resins offers the immediate and relatively inexpensive means to be recondition the surface of denture base directly However weak bond between denture base resin and reline material can harbor bacteria, promote staining, or result in complete separation of the two materials. Purpose : The purpose of this study was to evaluate the effect of denture cleansers on bond strength and surface hardness of reline resin to denture base resin Denture base resin beams($60.0{\times}15.0{\times}3.0mm$) were made with Lucitone 199. Material and methods : 10mm section was removed from the center of each specimen. The samples were replaced in the molds and the space of l0mm sections were packed with Tokuso Rebase reline material. The specimens were immersed in denture cleansers (Polident, Cleadent) and were evaluated after 1 week, 2 weeks, and 4 weeks. The bond strength and surface hardness of self-curing hard reline materials to heat-curing denture base resin were measured using an UTM (universal testing machine). Results and conclusion : 1) There was no significant difference of usage, kind, and denture cleaner by application time on the bonding strength of self-curing hard reline resin to denture base resin. 2) There was no significant difference of usage, kind, and denture cleaner by application time on the surface hardness, but the surface hardness showed decreasing tendency, as the time of immersion was extended. 3) The failure modes of the specimens was initially adhesive failure and finally cohesive failure of self-curing hard reline resin.

A COMPARATIVE STUDY OF SURFACE CHARACTERISTICS OF DIRECT RELINE RESINS (의치상 직접 이장재의 표면 특성에 관한 비교 연구)

  • An Jong-Kwan;Lee Joon-Kyu;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.49-57
    • /
    • 2001
  • The use of autopolymerizing-cured resin and light-cured resin for direct introral relining of complete and partial dentures has been popular. The purpose of this investigation was to determine the surface characteristics of autopolymerizing-cured reline resins(Tokuso rebase, Mild rebaron, Meta base) and light-cured reline resin(Mild rebaron LC). Acrylic resin slab specimens(1.0cm in diameter at the bottom, and 0.3cm high) were made against glass according to the instructions of the manufacturer following normal procedures for each of direct reline resins and examined the surface characteristics by use of surface profilometer and the other specimens which were made intraorally for each of direct reline resins were examined by use of scanning electron microscopy. The results were as follows : 1. Each surface roughness(Rz) of hard relin resins was $0.14{\pm}0.04{\mu}m$ in Tokuso rebase, $0.37{\pm}0.11{\mu}m$ in Mild Rebaron, $0.79{\pm}0.44{\mu}m$ in Mild Rebaron LC, $6.36{\pm}3.40{\mu}m$ in Meta base. There were significant differences between the surface roughness of Meta base and those of other reline resins(p<0.05) 2. The generation of porosity was the most in Tokuso Rebase and followed by Meta base, Mild Rebaron and Mild Rebaron LC in the order respectively. 3. Light-cured reline resin(Mild rebaron LC) was denser in surface than any other autopolymerizing-cured reline resins. Tokuso rebase and Mild rebaron was denser than Meta base. Conclusively, light-cured reline resin(Mild rebaron LC) had less porosity and better surface density than any other autopolymerizing-cured reline resins.

  • PDF

A STUDY ON THE BOND STRENGTH OF RELINE RESIN TO PRESSURE INJECTION TYPE THERMOPLASTIC DENTURE BASE RESIN (가압주사식 열가소성 의치상 레진과 이장 레진 간의 결합강도에 관한 연구)

  • Moon Tae-Sung;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.42-52
    • /
    • 2002
  • The purpose of this study was to evaluate the bond strength of reline resin to pressure injection type thermoplastic denture base resin. The denture base resins used in this study were $Hi-polycarbonate^{(R)}$(High Dental Co., Japan), Acetal $dental^{(R)}$(Pressingdental s.r.1., Repubblica di San Marine) of thermoplastic resin and Acron $MC^{(R)}$(GC Dental Industrial Co., Japan) of heat cured resin. The reline resins used were Lucitone $199^{(R)}$(Dentsply international Inc., USA), Tokuso $rebase^{(R)}$(Tokuyama Corp., Japan), and $Lightdon-U^{(R)}$(Dreve-Dentamid-Gmbh, Germany). The reline resins are representative of heat-cured, self-cured, and light-cured resin respectively Bond strength was examined by use of a three-point transverse flexural strength test. The results were as follows 1. The bond strength of Lucitone 199 to Acron MC was the highest. 2. The bond strengths of Lucitone 199 and Tokuso rebase to Hi-polycarbonate resulted in a value of approximately one half that of Lucitone 199 to Acron MC and there were no significant differences between these and the bond strength of Tokuso rebase to Acron MC(p<0.05) 3. The bond strengths of reline resins to Acetal dental were lower than those of reline resins to Hi-polycarbonate. 4. For all base resins Lightdon-U showed lower bond strength than the other reline resins.

AN EXPERIMENTAL STUDY ON THE DIMENSIONAL CHANGES OF RELINED DENTURES AND MECHANICAL PROPERTIES AND SURFACE TEXTURES OF SEVERAL RESINS USED IN DENTURE RELINING (수종 레진으로 의치상 조직면 개조시 의치상의 크기변화와 물리적 성질 및 표면상태 비교 연구)

  • Lee, Chang-Han;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.25-41
    • /
    • 1990
  • The purpose of this study was to evaluate and compare the dimensional changes of relined dentures with a light-curing resin, a heat-curing resin, and a direct, hard reline resin. And also to measure the transverse strength, impact strength, surface hardness of the three resins used in relining. The surface textures of three resins also of evaluated by using scanning electron microscope. Through analyses on the data from this study, the following conclusions were obtained. 1. Impact strength of heat-curing resin was highest, and direct, hard reline resin higher, light-curing resin lowest. 2. Transverse strength of heat-curing resin was highest, and direct, hard reline resin and light-curing resin was lower and not signiicantly different. 3. Surface hardness of light-curing resin was lighest, heat-curing resin higher, and direct, hard reline resin was lowest. 4. After storage of the relined dentures for 1 day and 1 week in water at room temperature, linear shrinkage of distance between the reference points in the maxillary base relined with direct, hard reline resin was lowest, and those relined with light-curing resin and heat-curing resin were lower and were not significantly different. 5. After storage for 4 weeks in orator at room tempeature, linear shrinkage of distance between ridge crests of dentures relined with heat-curing resin was highest and that of distance between denture borders was not significantly different. 6. The dimensional changes of relined dentures during storage in water was not significant except those of distance between denture borders relined with light-curing resin at 1 day and 1 week storage in water. 7. At low magnification (x40) of SEM examination, the surface textures of three resins were similar except light-curing resin which had some defects. At high magnification (x200), the surface textures of hard, direct reline resin were smooth with little defects, but those of heat-curing resin and light-curing resin w ere irregular.

  • PDF

A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base (광중합형 이장재와 금속의치상 간의 결합력에 관한 연구)

  • Park, In-Chae;Lee, Joon-Kyu;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.211-220
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recommendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univesal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strength than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strength of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

A Study on the Tensile Strength between Light-cured Relining Resin and Metal Denture Base (광중합형 이장재와 금속의치상 간의 결합력에 관한 연구)

  • Park, In-Chae;Lee, Joon-Kyu;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.2
    • /
    • pp.161-170
    • /
    • 2000
  • The use of autopolymerizing-cured resin and light-cured resin for direct relining of complete and partial dentures has been popular. This investigation compared the adhesion of autopolymerizing-cured reline resin(Tokuso Rebase, Mild Rebaron) or light-cured reline resin(Mild Rebaron LC, Lighton-U) to metal base or resin base. Cylindrical samples were made from metal($Biosil^{(R)}$) or heat-cured resin(QC-20) and were prepared to produce a flat bonding surface. Cylindrical metal samples were roughened by scratch or by scratch and sandblast and were treated with primer(MR Bond) after scratch and sandblast. And then, liners were prossesed to the cylindrical metal or resin samples according to the manufacturer's recomendations so as to bond metal base or resin base. The specimens were tested in pure tension by using an Instron Univasal testing machine for the four direct reline resins. The results were as follows ; 1. In comparison with tensile bond strength of material relined on resin base or metal base, the case of resin base produced significantly higher tensile bond strengths than the case of metal base. 2. Metal surface pretreatment or primer improved the tensile bond strength between the reline resin and the metal($Biosil^{(R)}$) base. 3. The tensile bond strengths of Mild Rebaron LC relined on resin base or metal base were similar to those of the other reline resins.

  • PDF

THE CHANCE IN TRANSVERSE STRENGTH OF DENTURE BASE AFTER RELINE PROCEDURE (개상한 의치상의 전단굴곡강도 변화)

  • Kim, Seon-Young;Vang, Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.782-790
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of proportional thickness of various reline materials on the transverse strength of denture base. The denture base resin used in this study was Vertex $RS^{(R)}$ (Dentimex Zeist., Holland). The reline resins used were Tokuso $rebase^{(R)}$ normal set (Tokuyama Corp., Japan), $Rebaron^{(R)}$ (GC Corp., Japan), $Kooliner^{TM}$ (GC INC., U.S.A), New $truliner^{TM}$(Harry J. Bosworth Co., U.S.A). The bulk specimens with 2.5mm thickness of denture base were prepared as the control group. Group 1 was fabricated with 2.0mm thickness of denture base and 0.5mm reline material, group 2 with 1.5:1.0mm, group 3 with 1.0:1.5mm, group 4 with 0.5:2.0mm composition. Measurements of transverse strength were taken for each specimens The results were as follows: 1. Regardless of the reline resin type, the transverse strength of denture base was decreased after reline procedure. 2. The transverse strength according to the reline resin type was decreased in the following order : Rebaron, Tokuso rebase, Kooliner, and then New truliner and there was a significant difference among the reline materials (P<0.05). 3. The strength of the relined denture base generally decreased as the proportional thickness of the denture reline material increased. These results suggest that increasing the proportional thickness of the reline material progressively decreased the strength of the relined denture base. Thus, the denture base should not be unnecessarily altered during the reline procedure.

  • PDF

Bond strength of denture base resin repaired according to contamination (의치상 수리면 오염원에 따른 수지의 결합강도)

  • Jung, Kyung-Pung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.71-79
    • /
    • 2003
  • The purpose of this study was to investigate bond strength of denture base resin repaired according to contamination. One commercial denture base resin and two different kinds of relines resin were tested; Lusiton 199(denture base resin), Vertex(reline resin) and TokusoRebase(repair resin). The specimens were processed according to the manufacturer's instructions to cured denture base resin(polymethylmethacrylate; PMMA) and reline resin. Bond strengths were examined by use of a three-point transverse flexural strength test. Data were analyzed with two-factor analysis of variance and Duncan's post-hoc test at $\alpha$=0.05. Generally, the bondstrength of heat-cured resin(Lusiton 199) was higher than the other resins. The contaminations produced an decrease in bond strength. Therefore the contamination, such as saliva or water must be avoided during the laboratory repair procedures.

  • PDF

Effect of surface treatment methods on the shear bond strength of auto-polymerized resin to thermoplastic denture base polymer

  • Koodaryan, Roodabeh;Hafezeqoran, Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.504-510
    • /
    • 2016
  • PURPOSE. Polyamide polymers do not provide sufficient bond strength to auto-polymerized resins for repairing fractured denture or replacing dislodged denture teeth. Limited treatment methods have been developed to improve the bond strength between auto-polymerized reline resins and polyamide denture base materials. The objective of the present study was to evaluate the effect of surface modification by acetic acid on surface characteristics and bond strength of reline resin to polyamide denture base. MATERIALS AND METHODS. 84 polyamide specimens were divided into three surface treatment groups (n=28): control (N), silica-coated (S), and acid-treated (A). Two different auto-polymerized reline resins GC and Triplex resins were bonded to the samples (subgroups T and G, respectively, n=14). The specimens were subjected to shear bond strength test after they were stored in distilled water for 1 week and thermo-cycled for 5000 cycles. Data were analyzed with independent t-test, two-way analysis of variance (ANOVA), and Tukey's post hoc multiple comparison test (${\alpha}=.05$). RESULTS. The bond strength values of A and S were significantly higher than those of N (P<.001 for both). However, statistically significant difference was not observed between group A and group S. According to the independent Student's t-test, the shear bond strength values of AT were significantly higher than those of AG (P<.001). CONCLUSION. The surface treatment of polyamide denture base materials with acetic acid may be an efficient and cost-effective method for increasing the shear bond strength to auto-polymerized reline resin.

THE BOND STRENGTH OF REBASE RESIN TO DENTURE BASE RESIN (의치상 레진에 대한 개상용 레진의 결합 강도에 관한 연구)

  • Kim Il-Pyung;Cho Hye-Won;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.515-522
    • /
    • 1993
  • The purpose of this study was to evaluate the bond strength of rebase resin to denture base resin. The denture base resins in this study were Premium Super-20(Lang Dental Mfg. Co. Inc., Wheeling, USA) and Lucitone 199(Dentsply International Inc., York, USA). And the rebase resins were Repair Acrylic(Lang Dental Mfg. Co. Inc., Wheeling USA). Toughron Rebase(Miki Chemical Product Co. Ltd., Japan) , Tokuso Rebase(Tokuyama Soda. Co. Ltd., Japan) and Triad VLC Reline Material(Dentsply International Inc., York, USA). The obtained results were as follows : 1. The bond strength of Repair Acrylic to Premium Super-20, and that of Toughron Rebase to Lucitone 199 were the highest. 2. In Premium Super-20 and Lucitone 199, bond strength of all rebase resins had significant differences. 3. The bond strength of Triad VLC Reline Material was inclined to the lowset.

  • PDF