• 제목/요약/키워드: Reliability Simulator

검색결과 286건 처리시간 0.026초

A Study on Temperature Dependent Super-junction Power TMOSFET

  • Lho, Young Hwan
    • 전기전자학회논문지
    • /
    • 제20권2호
    • /
    • pp.163-166
    • /
    • 2016
  • It is important to operate the driving circuit under the optimal condition through precisely sensing the power consumption causing the temperature made mainly by the MOSFET (metal-oxide semiconductor field-effect transistor) when a BLDC (Brushless Direct Current) motor operates. In this letter, a Super-junction (SJ) power TMOSFET (trench metal-oxide semiconductor field-effect transistor) with an ultra-low specific on-resistance of $0.96m{\Omega}{\cdot}cm^2$ under the same break down voltage of 100 V is designed by using of the SILVACO TCAD 2D device simulator, Atlas, while the specific on-resistance of the traditional power MOSFET has tens of $m{\Omega}{\cdot}cm^2$, which makes the higher power consumption. The SPICE simulation for measuring the power distribution of 25 cells for a chip is carried out, in which a unit cell is a SJ Power TMOSFET with resistor arrays. In addition, the power consumption for each unit cell of SJ Power TMOSFET, considering the number, pattern and position of bonding, is computed and the power distribution for an ANSYS model is obtained, and the SJ Power TMOSFET is designed to make the power of the chip distributed uniformly to guarantee it's reliability.

Ad-Hoc 네트워크를 이용한 모바일 그리드의 구조 설계 (The Design of Mobile Grid Architecture using Ad-Hoc Network)

  • 김태경;서희석;김희완
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권2호
    • /
    • pp.345-354
    • /
    • 2005
  • 그리드 사용자에게 시간과 장소에 상관없이 그리드 서비스를 이용할 수 있게 해주는 기술이 모바일 그리드이다. 이동환경에서 그리드 서비스를 제공하기 위해서는 단말기 배터리의 성능 및 이동성의 고려 등 여러 가지 제약사항이 따르며, 유선망에서의 그리드 기술을 이동 환경에 적용하기에는 많은 어려움이 있다. 따라서 본 논문에서는 모바일 그리드 서비스를 제공하기 위한 모바일 그리드 구조를 Ad-hoc 네트워크를 이용하여 설계를 하였으며, NS-2(Network Simulator)를 이용한 시뮬레이션을 통한 세 가지 방법의 라우팅 프로토콜의 지연시간에 대한 측정 및 이동 단말기 배터리의 성능을 고려한 비교를 통해, hybrid 방식의 라우팅 프로토콜이 효율적임을 제시하였다. 향후 모바일 그리드 서비스를 제공하기 위한 자원 할당 및 신뢰성 확보 방안에 대한 연구를 수행할 예정이다.

  • PDF

MRFR - Multipath-based Routing Protocol with Fast-Recovery of Failures on MANETs

  • Ngo, Hoai Phong;Kim, Myung Kyun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권2호
    • /
    • pp.271-287
    • /
    • 2013
  • We propose a new multipath-based reliable routing protocol on MANETs, Multipath-based Reliable routing protocol with Fast-Recovery of failures (MRFR). For reliable message transmission, MRFR tries to find the most reliable path between a source and a destination considering the end-to-end packet reception reliability of the routes. The established path consists of a primary path that is used to transmit messages, and the secondary paths that are used to recover the path when detecting failures on the primary path. After establishing the path, the source transmits messages through the primary path. If a node detects a link failure during message transmission, it can recover the path locally by switching from the primary to the secondary path. By allowing the intermediate nodes to locally recover the route failure, the proposed protocol can handle the dynamic topological change of the MANETs efficiently. The simulation result using the QualNet simulator shows that the MRFR protocol performs better than other protocols in terms of the end-to-end message delivery ratio and fault-tolerance capability.

RTDS를 이용한 신재생에너지 기반 마이크로그리드 시뮬레이션 해석 (Simulation analysis of a renewable energy based microgrid using RTDS)

  • 허세림;김경훈;이효근;황철상;박민원;유인근;박정도;이동영;이상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.143-144
    • /
    • 2011
  • Due to enhanced demands on quality, security and reliability of the electric power energy system, a microgrid has become a subject of special interest. In this paper, output characteristics of energy storage system (ESS) with an electric double layer capacitor (EDLC) and battery energy storage system (BESS) of a renewable energy based microgrid were analyzed under grid-connected and islanded operation modes. The microgrid which consists of photovoltaic and wind power turbine generators, diesel generator, ESS with an EDLC, BESS and loads was modeled using real time digital simulator. The results present the effective control patterns of the microgrid system.

  • PDF

Feedwater Flowrate Estimation Based on the Two-step De-noising Using the Wavelet Analysis and an Autoassociative Neural Network

  • Gyunyoung Heo;Park, Seong-Soo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.192-201
    • /
    • 1999
  • This paper proposes an improved signal processing strategy for accurate feedwater flowrate estimation in nuclear power plants. It is generally known that ∼2% thermal power errors occur due to fouling Phenomena in feedwater flowmeters. In the strategy Proposed, the noises included in feedwater flowrate signal are classified into rapidly varying noises and gradually varying noises according to the characteristics in a frequency domain. The estimation precision is enhanced by introducing a low pass filter with the wavelet analysis against rapidly varying noises, and an autoassociative neural network which takes charge of the correction of only gradually varying noises. The modified multivariate stratification sampling using the concept of time stratification and MAXIMIN criteria is developed to overcome the shortcoming of a general random sampling. In addition the multi-stage robust training method is developed to increase the quality and reliability of training signals. Some validations using the simulated data from a micro-simulator were carried out. In the validation tests, the proposed methodology removed both rapidly varying noises and gradually varying noises respectively in each de-noising step, and 5.54% root mean square errors of initial noisy signals were decreased to 0.674% after de-noising. These results indicate that it is possible to estimate the reactor thermal power more elaborately by adopting this strategy.

  • PDF

그리드/연계선 사고 시 풍력발전단지의 응동 분석 (Analysis of Response of a Wind Farm During Grid/inter-tie Fault Conditions)

  • 이혜원;김연희;정태영;이상철;강용철
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1128-1133
    • /
    • 2011
  • In a wind farm, a large number of small wind turbine generators (WTGs) operate whilst a small number of a large generator do in a conventional power plant. To maintain high quality and reliability of electrical energy, a wind farm should have equal performance to a thermal power plant in the transient state as well as in the steady state. The wind farm shows similar performance to the conventional power plant in the steady state due to the advanced control technologies. However, it shows quite different characteristics during fault conditions in a grid, which gives significant effects on the operation of a wind farm and the power system stability. This paper presents an analysis of response of a wind farm during grid fault conditions. During fault conditions, each WTG might produce different frequency components in the voltage. The different frequency components result in the non-fundamental frequencies in the voltage and the current of a wind farm, which is called by "beats". This phenomenon requires considerable changes of control technologies of a WTG to improve the characteristics in the transient state such as a fault ride-through requirement of a wind farm. Moreover, it may cause difficulties in protection relays of a wind farm. This paper analyzes the response of a wind farm for various fault conditions using a PSCAD/EMTDC simulator.

Electric Propulsion Naval Ships with Energy Storage Modules through AFE Converters

  • Kim, So-Yeon;Choe, Sehwa;Ko, Sanggi;Kim, Sungmin;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.402-412
    • /
    • 2014
  • This paper proposes a novel electric propulsion system for naval ships, which consists of Active Front End (AFE) converters directly connected to battery Energy Storage Modules (ESMs). Employing the proposed AFE converters with ESMs in the power systems of naval ships can enhance the reliability and quality of the electric power. Furthermore, the fuel-efficiency of the generator can be improved by a higher loading factor of the generator and its prime movers. The proposed AFE configuration does not require an additional dedicated DC/AC converter for the ESMs. Instead of that, the AFE converter itself can control the DC link voltage and the discharging and/or charging of the ESMs. A control scheme to achieve these control objectives is also presented in this paper. The overall power system, including the generators and electrical loads of a naval ship, is implemented by a small scaled Power Hardware-In-the-Loop (PHIL) simulator. Through this experimental setup, the proposed system configuration and the power control strategies are verified. It is shown that the fuel-efficiency and transient dynamics can be improved in the normal and contingency operation modes.

발전기 계자 접지 검출회로 신뢰성 점검에 관한 연구 (A Study Of Reliability Check Method for Generator Field Ground Detectors)

  • 천영식;박호철;원학재;한승문;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.585-587
    • /
    • 1999
  • The rotorbody and rotor winding of generator are isolated by an insulator and the output characteristic of the generator is maintained in the best states. Only when an insulation resistance between them is over a certain extent. The aim of this research is to develop the simulator for rotor earth fault detection circuits. It is composed of the power resource which is to control the virtual field voltage, stepping motor which is to give virtual ground. It is possible to inspect with the device and program developed in this study in the same as real operating condition and evaluate the integrity of generator rotor through the function of data acquisition and graphic output. If these technologies will be applied to the inspection, prevent a damage of the generator and contribute to improve maintenance reliance.

  • PDF

Smart열차진로제어를 위한 선로데이터 생성관리프로그램의 데이터 구조 (Data Structure of a Program Generation and Managing Track Data for Smart Train Route Control)

  • 윤용기;황종규;조현정;이재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.234-236
    • /
    • 2007
  • Even though the existing train route controlling method, using track circuits, ensures the sufficient number of operation, it still has problems such as discordance between train numbers which was planned for operating and train numbers being operated on the track, and allowing only one train entering for one route. To solve those problems, we study and develop the Smart train route controlling system which uses the real-time informations of train positions. This system enables improve the coefficient of utilization in a certain train route controlling section, and the safety level of train route controlling, but we should ensure satisfying reliability of data about tracks operated by trains. In addition, there is a need to protect accidents caused by erroneous information of train position, by reflecting changes of tracks, for example maintenance, improvement, expansion of tracks. In this paper, we describes data structure of a developed program which required to change CAD files to wiring diagrams and to generate them to data of tracks. And we show the result that the simulator, using the data structure, controls speed and route of trains without problems.

  • PDF

콜드체인 시스템의 센서태그 운영 최적화를 위한 DEVS 기반 시뮬레이션 모델 (DEVS-Based Simulation Model for Optimization of Sensor-Tag Operations in Cold Chain Systems)

  • 류옥현;강용신;진희주;이용한
    • 대한산업공학회지
    • /
    • 제41권2호
    • /
    • pp.173-184
    • /
    • 2015
  • The application of radio frequency identification (RFID) sensor-tags in cold chain systems has recently received a great deal of attention. To design cold chain systems with RFID sensor-tags that minimize the initial investment and operational cost while fulfilling the functional and operational requirements, simulation study is one of the preferable and effective approaches. To simulate the possible design configurations, the individual components in a cold chain system can be extracted and implemented as a DEVS (Discrete Event System Specification) model. Based on the proposed DEVS model, a new cold chain simulation model can be efficiently created by simply connecting each DEVS model around the RFID sensor-tag of interest in sequence according to the structure of the cold chain system, and then executed (or simulated) on Java programming environments by the DEVSJAVA simulator. As a result of simulation, some key performance indexes such as reliability, accuracy or timeliness can be calculated and used to choose better components or to compare different system configurations of cold chain systems.