• 제목/요약/키워드: Reliability Demonstration Test

검색결과 57건 처리시간 0.022초

와이블 분포를 이용한 플랩구동장치의 무고장 가속수명시험 (No-Failure Accelerated Life Test of Flap Actuating System using Weibull Distribution)

  • 조현준;이인호;김상범;박상준;양명석
    • 항공우주시스템공학회지
    • /
    • 제10권1호
    • /
    • pp.51-58
    • /
    • 2016
  • In this paper, we present some results on No-failure accelerated life test of aerial vehicle for reliability demonstration. The design of general accelerated life test consists of the three phases: 1) Estimating normal life test time of a single product from Weibull distribution model; 2) Determining the acceleration factor (AF) by utilizing the relation between the life of mechanical components and the applied torque; 3) Calculating the accelerated life test time, which comes from dividing the estimated normal life test time into AF. Then, we applied the calculated life test time to the real reliability test of the flap actuating system, while considering the requirement specification for mechanical components and operating environment of the actuation system. Real experimental processes and results are presented to validate the theory.

전력산업용 PV System의 각 용량별 설계 파라미터 도출에 관한 연구 (Study on the Elicitation of Parameter in Designing each Capacity of PV System for Power Industry)

  • 김병만;이길송;양연원;신현우;김의환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.78.1-78.1
    • /
    • 2010
  • Recently, as much supplied with new-renewable energy, as much invested in PV system. PV system consists of PV module, PCS and Monitering system, and also could be classified into the type and the capacity by installation method and cost etc. When various systems are installed in the field, it is needed to research for applying in the field and establish infrastructure in order to ensure stable efficiency and reliability. In this study, as the basic design of the demonstration test facility, it is designed the basic PV systems for each capacity to test each PCS. In addition, It is drew the climatic conditions such as insolation, temperature and the design parameters such as installation angle, shades for the local demonstration project and expected the generation of each PV system.

  • PDF

75톤급 채널냉각 연소기 저압연소시험 (Low Pressure Firing Tests of 75-tonf-Class Channel Cooling Thrust Chamber)

  • 임병직;한영민;김종규;서성현;안규복;김문기;이광진;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.71-74
    • /
    • 2010
  • 한국형발사체 엔진에 사용될 것으로 예상되는 75톤급 연소기의 기술검증시제를 이용하여 2회 연소시험을 수행하였다. 설비 공급 능력과 구조물 강도 제한으로 정상 유량의 50% 수준에서 시험이 수행되었다. 채널냉각 연소기를 이용한 저압연소시험을 통해 점화구간과 연소구간에서의 신뢰도와 안정성이 확인되었다. 더불어 75톤 연소기가 성능요구조건을 만족시킬 수 있을 것으로 추정할 수 있었다.

  • PDF

태양열 온수기 실증연구를 통한 성능 평가 (Performance Evaluation of Solar Water Heating System Using Proof Test)

  • 김재열;곽이구;양동조;최철준;김홍건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

에너지저장장치(ESS) 융복합 전문평가센터 기반구축 (Foundation Establishment of Professional Evaluation Center for Convergence of Energy Storage System (ESS))

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권4호
    • /
    • pp.165-170
    • /
    • 2020
  • 빠르게 성장하는 신재생 ESS 부품 소재 시장 선점과 급변하는 세계 신재생 ESS 시장에서 국내 중소기업이 대응하기에는 한계가 있으며 이를 극복하기 위한 대·중소기업 협력 기반구축과 중·장기적으로 신재생에너지 산업육성을 촉진할 수 있는 신재생 ESS 융복합 사업화 지원센터를 구축할 필요성이 커지고 있다. 따라서 신재생 ESS 융복합 전문평가센터 기반구축을 통해 신재생 ESS 제품에 대한 성능평가 및 표준화를 통해 제품의 신뢰성을 높이고, 신재생 ESS의 신뢰성 확보를 통해 국내 보급사업 및 수출 활성화를 촉진할 수 있다. 또한, 국내 연구기관, 제조업체의 개발 역량 제고 및 경쟁력 강화를 지원하고 Total-test 시험평가 시스템에 따른 시험비용 및 시험 기간의 단축을 실현하여 국내 기업이 해외 시험기관을 이용할 때 발생할 수 있는 국내 기술의 유출방지 효과를 기대할 수 있다. 따라서 본 논문에서는 이러한 성능 평가 및 실증을 위해 표준화를 정립할 수 있는 선진국 수준 이상의 전문평가센터 구축을 연구하고자 한다.

과학학습에서 불일치 상황에 대면한 초등학생의 인지갈등 측정 도구 개발 (The Development of an Instrument for the Measuring Cognitive Conflict Levels of Elementary Students Confronted with an Anomalous Situation in Science Learning)

  • 박상석;이경호;김정환;권혁구;권재술
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제18권2호
    • /
    • pp.21-33
    • /
    • 1999
  • The purpose of this study was to develop an Instrument for the Measurement of Cognitive Conflict Levels of students who confronted with an anomalous situation in science teaming. Anomalous situation is generated when students' prediction is disconsistent with the observed fact. In this study, the researchers identified 4 components of cognitive conflict and developed three items for each component. The items were developed and revised by four pilot tests. In the first pilot test, 55 elementary school students participated in the test In the second pilot test, 88 students of the 5th and 6th grader participated in the test. The instrument of measuring cognitive conflict levels was given to the subjects right after demonstrating anomalous situation. For the demonstration, two different problem situations were developed: one was a pulley problem and the other was electric bulbs in parallel. Answered reasons for each items were analyzed to assess students' understanding on each items. In third pilot test, 125 elementary school students participated in the test. A factor analysis of the responses was carried out and reliability of the test was assessed by calculating internal consistency values. The items were finalized by three pilot tests. After 1 month after the third pilot test, researchers conducted the finalized test items to 323 students of the 5th and 6th grader. The final instrument showed moderate reliability (Cronbach-α 0.82∼0.87) and good content validity(0.93). A factor analysis of the response was carried out. 4 main factors completely coincided with 4 components that we supposed to be the conducts of cognitive conflict. The instrument can provide a means for both teachers and researchers to assess the cognitive conflict of a large number of students within a single class period. The results can be used by teachers to better understand the process of conceptual change of their students and to match instruction and materials accordingly.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Monitoring and Analysis of 3kW Grid-Connected PV System for Performance Evaluation

  • So Jung-Hun;Jung Young-Seok;Yu Gwon-Jong;Choi Ju-Yeop;Choi Jae-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.57-62
    • /
    • 2005
  • Grid-connected photovoltaic (PV) systems were installed and monitored at the field demonstration test center (FDTC) in Korea in October 2002. Before long-term field testing of installed PV systems, the performances of PV components were evaluated and compared through short-term performance tests of each of the PV system components such as power conditioning system and PV module under standard test conditions. A data acquisition system has been constructed for measuring and analyzing the performance of PV systems to observe the overall effect of environmental conditions on their operation characteristics. Performances of PV systems have been evaluated and analyzed not only for component perspective (PV array, power conditioning unit) but also for global perspective (system efficiency, capacity factor, electrical power energy) by review of the field test and loss factors of the systems. These results indicate that it is highly imperative to develop an optimum design technology of grid connected PV systems. The objective of this paper is not only to evaluate and analyze the performance of domestic PV systems application through long-term field testing at FDTC but also to develop evaluation, analysis and optimum technology for long-term stability and reliability of grid-connected PV systems in Korea.

전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석 (Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System)

  • 오관일;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF